    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 2 24 01 JAM total counter clear (JAM TTL CLR.)
    04 ADF counter clear (ADF CLR.) (Disabled when set to 
    OC) (Executable only when the ADF is installed.)
    05 Duplex counter clear (DPLX CLR.) (Enabled when 
    Duplex setting is ON)
    06 Developer counter clear (DVLP CLR.)
    07 Drum counter clear (DRUM CLR.)
    08 Copy counter clear (COPIES CLR.)
    09 Printer counter clear (PRT.CLR.)
    10 FAX counter clear (FAX CLR.) (Executable only when the 
    FAX is installed.)
    13 Scanner counter clear (SCAN CLR.)
    14 ADF JAM total counter clear (S JAM TTL CLR.) 
    (Disabled when set to OC) (Executable only when the 
    ADF is installed.)
    15 Scanner mode counter clear (S-MODE CLR.)
    25 01 Main motor operation check (MAIN MOTOR CHK)
    10 Polygon motor operation check (LSU CHK)
    26 02 (R)ADF setting (ADF/RADF) (Executable only when the 
    ADF/RADF is installed.)
    03 Second cassette setting (2ND TRAY)
    04 Main unit duplex setting (DPLX) (Executable only when 
    the RADF is installed.)
    06 Destination setting (DESTINATION)
    07 Machine conditions check (CPM)
    20 Rear edge void setting (END EDGE)
    30 CE mark support control ON/OFF (CE MARK)
    37 Cancel of stop at developer life over (DVLP LIFE END)
    39 Memory capacity check (MEM.CHK)
    40 Polygon motor OFF time setting (Time required from 
    completion of printing to turning OFF the motor) (LSU 
    MOTOR OFF)
    42 Transfer ON timing control setting (TC ON TIMING)
    43 Side void amount setting (SIDE VOID)
    62 Energy-save mode copy lamp setting (C-LAMP E-S)
    30 01 Paper sensor status display (P-SENSOR)
    41 06 OC cover float detection level (OC FLOAT LEVEL) 
    (Disabled when set to OC) (Executable only when the 
    ADF/RADF is installed.)
    43 01 Fusing temperature setting (Normal copy) (FU TEMP)
    04 Fusing temperature setting in multi coy (FU TEMP 
    MULTI)
    05 Fusing temperature setting in duplex copy (FU TEMP 
    DPLX) (Enabled when Duplex setting is ON)
    14 Fusing start temperature setting (FU TEMP START)
    46 01 Copy density adjustment (300dpi) (EXP.LEVEL 300)
    02 Copy density adjustment (600dpi) (EXP.LEVEL 600)
    12 Density adjustment in the FAX mode (Collective 
    adjustment) (Executable only when the FAX is installed.)
    13 FAX mode density adjustment (normal text) (Executable 
    only when the FAX is installed.)
    14 FAX mode density adjustment (Fine text) (Executable 
    only when the FAX is installed.)
    15 FAX mode density adjustment (Super fine) (Executable 
    only when the FAX is installed.)
    18 Image contrast adjustment (300dpi) (GAMMA 300)
    19 Exposure mode setting (AE MODE)
    20 ADF exposure correction (EXP.LEVEL ADF) (Disabled 
    when set to OC) (Executable only when the ADF is 
    installed.)
    29 Image contrast adjustment (600dpi) (GAMMA 600)
    30 AE limit adjustment (AE LIMIT)
    31 Image sharpness adjustment (SHARPNESS) Main 
    codeSub 
    codeContents
    46 32 Copier color reproduction setting (COLOR REAPPEAR)
    39 FAX mode sharpness adjustment (Executable only when 
    the FAX is installed.)
    48 01 Mains can/sub scan direction magnification ratio (COPY 
    MAG.)
    05 ADF/RADF mode sub scan direction magnification ratio 
    in copying (ADF/RADF MAG.) (Disabled when set to OC) 
    (Executable only when the ADF/RADF is installed.)
    49 01 Download mode (DOWNLOAD MODE)
    50 01 Lead edge image position (LEAD EDGE)
    06 Copy lead edge position adjustment (ADF/RADF) (ADF/
    RADF EDGE) (Disabled when set to OC) (Executable 
    only when the ADF/RADF is installed.)
    10 Print center offset adjustment (PRT.OFF-CENTER)
    12 Document feed off-center adjustment (ORG.OFF-
    CENTER)
    18 Memory reverse position adjustment in duplex copy 
    (DPLX REVERSE) (Enabled when Duplex setting is ON 
    with OC or ADF set) (Executable only when the RADF is 
    installed.)
    19 Duplex copy rear edge void adjustment (DPLX END 
    EDGE) (Enabled when Duplex setting is ON) (Executable 
    only when the RADF is installed.)
    51 02 Resist amount adjustment (RESIST ADJ.)
    53 08 ADF scan position automatic adjustment (ADF AUTO) 
    (Disabled when set to OC) (Executable only when the 
    ADF is installed.)
    61 03 HSYNC output check (LSU CHK)
    63 01 Shading check (SHADING CHK)
    02 Black level automatic correction (BLACK LEVEL)
    64 01 Self print (1by2 mode) (SELF PRT.)
    66 01 FAX soft SW setting (Executable only when the FAX is 
    installed.)
    02 FAX soft SW initializing (excluding the adjustment 
    values) (Executable only when the FAX is installed.)
    03 FAX PWB memory check (Executable only when the 
    FAX is installed.)
    04 Signal send mode (Max. value) (Executable only when 
    the FAX is installed.)
    05 Signal send mode (Soft SW set value) (Executable only 
    when the FAX is installed.)
    07 Image memory content print (Executable only when the 
    FAX is installed.)
    10 Image memory content clear (Executable only when the 
    FAX is installed.)
    11 300bps signal send (Max. value) (Executable only when 
    the FAX is installed.)
    12 300bps signal send (Soft SW set value) (Executable only 
    when the FAX is installed.)
    13 Dial test (Executable only when the FAX is installed.)
    17 DTMF signal send (Max. value) (Executable only when 
    the FAX is installed.)
    18 DTMF signal send (Soft SW set value) (Executable only 
    when the FAX is installed.)
    21 FAX information print (Executable only when the FAX is 
    installed.)
    24 FAST SRAM clear (Executable only when the FAX is 
    installed.)
    30 TEL/LIU status change check (Executable only when the 
    FAX is installed.)
    32 Receive data check (Executable only when the FAX is 
    installed.)
    33 Signal detection check (Executable only when the FAX is 
    installed.) Main 
    codeSub 
    codeContents
    e-STUDIO162_151.book  2 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 3
    4. Descriptions of various test commands
    66 34 Communication time measurement (Executable only 
    when the FAX is installed.)
    37 Speaker sound volume setting (Executable only when 
    the FAX is installed.)
    38 Time setting/check (Executable only when the FAX is 
    installed.)
    41 CI signal check (Executable only when the FAX is 
    installed.) Main 
    codeSub 
    codeContents
    Main 
    codeSub 
    codeContents Details of function/operation
    1 01 Mirror scan (SCAN CHK)[Function]
    When [OK (ENTER)/START] key is pressed, the home position is checked and the mirror base per-
    forms full scan at the speed of the set magnification ratio.
    During operation, the set magnification ratio is displayed.
    The mirror home position sensor status is displayed with the “COPY mode lamp”. (When the mirror is
    in the home position, the lamp lights up.)
    During operation, the copy lamp lights up.
    When [C] key is pressed, if the operation is on the way, it is terminated and the machine goes to the
    sub code entry standby mode.
    [Operation]
    02 Mirror home position sensor 
    (MHPS) status display 
    (MHP-SENSOR)[Function]
    Monitors the mirror home position sensor, and makes the COPY mode lamp turn on during the sen-
    sor ON status.
    [Operation]
    06 Mirror scan aging (SCAN 
    AGING)[Function]
    When [OK (ENTER)/START] key is pressed, the mirror base performs full scan at the speed of the set
    magnification ratio.
    During operation, the set magnification ratio is displayed.  
    After 3sec, the mirror base performs full scan again. 
    ∗When [OK (ENTER)/START] key is pressed once, the ready lamp remains OFF.
    The mirror home position sensor status is displayed on the COPY mode lamp. (The lamp is ON
    when the mirror is in the home position.)
    During aging, the copy lamp is ON.
    [Operation]
    The operation is similar to test command 1-01.
    2 01 Single Paper Feeder (ADF) 
    aging (ADF AGING) 
    (Disabled when set to OC) 
    (Executable only when the 
    ADF is installed.)[Function]
    When [OK (ENTER)/START] key is pressed, the set magnification ratio is acquired and single-face
    document transport is performed in the case of ADF or duplex document transport in the case of R-
    ADF.
    However, the operating conditions dont matter and the operation is not stopped even in case of a
    jam.  Also the magnification ratio is displayed on the LCD.
    [Operation]
    The operation is similar to test command 1-01.
    1) Initial display
    2) [ZOOM]2) [←]
    2) [
    →]3) [OK (ENTER)/START]
    01-01 SCAN CHK
                - 100% +
    01-01 SCAN CHK
                -  78% +01-01 SCAN CHK
                -  99% +
    01-01 SCAN CHK
                - 101% +01-01 SCAN CHK
    EXECUTING... -  78% +
    1) Initial display
    01-02  MHP-SENSOR
    EXECUTING...
    e-STUDIO162_151.book  3 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 4 2 02 ADF sensor status display 
    (ADF SENSOR) (Disabled 
    when set to OC) (Executable 
    only when the ADF is 
    installed.)[Function]
    The ON/OFF status of the ADF sensors can be checked with the LCD.
    When a sensor is ON, the sensor name is displayed on the LCD. 
    [Operation]
    03 ADF motor operation check 
    (ADF MOTOR CHK) 
    (Disabled when set to OC) 
    (Executable only when the 
    ADF is installed.)[Function]
    When [OK (ENTER)/START] key is pressed, the motor rotates for 10sec at the speed corresponding
    to the set magnification ratio. 
    [Operation]
    The operation is similar to test command 1-01.
    06 RADF resist clutch operation 
    check (RADF RES.CHK) 
    (Enabled only when RADF is 
    set.) (Executable only when 
    the RADF is installed.)[Function]
    When [OK (ENTER)/START] key is pressed, the RADF resist clutch (SRRC) repeats ON for 500ms
    and OFF for 500ms 20 times.
    [Operation]
    08 ADF paper feed solenoid 
    operation check (ADF SPUS 
    CHK) (Disabled when set to 
    OC) (Executable only when 
    the ADF is installed.)[Function]
    The ADF paper feed solenoid (SPUS) repeats ON for 500ms and OFF for 500ms 20 times by the use
    of the solenoid drive control Bios.
    [Operation]
    09 RADF reverse solenoid 
    operation check (RADF 
    SPFS CHK) (Enabled only 
    when RADF is set.) 
    (Executable only when the 
    RADF is installed.)[Function]
    The ADF reverse solenoid (SPFS) repeats ON for 500ms and OFF for 500ms 20 times by the use of
    the solenoid drive control Bios.
    [Operation]
    10 RADF paper exit gate 
    solenoid operation check 
    (RADF SGS CHK) (Enabled 
    only when RADF is set.) 
    (Executable only when the 
    RADF is installed.)[Function]
    The ADF paper exit gate solenoid (SGS) repeats ON for 500ms and OFF for 500ms 20 times by the
    use of the solenoid drive control Bios.
    [Operation]
    3 03 Shifter operation check 
    (SHIFTER CHK)[Function]
    The shifter is moved back and forth in four reciprocations.
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    Sensor Display item
    Document set sensor SPID
    ADF document transport sensor SPPD
    ADF paper feed cover open/close sensor SDSW
    1) Initial display 2) When the sensor is ON:
    02-02 ADF SENSOR02-02 ADF SENSOR
    SPID SPPD SDSW
    1) Initial display
    02-06 RADF RES.CHK
    EXECUTING...
    1) Initial display
    02-08 ADF SPUS CHK
    EXECUTING...
    1) Initial display
    02-09 RADF SPFS CHK
    EXECUTING...
    1) Initial display
    02-10 RADF SGS CHK
    EXECUTING...
    1) Initial display
    03-03 SHIFTER CHK
    EXECUTING...
    e-STUDIO162_151.book  4 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 5 5 01 Operation panel display 
    check (LCD/LED CHK)[Function]
    
    When [OK (ENTER)/START] key is pressed, all the LCDs on the operation panel are turned ON (all
    pixels ON).
    After 5sec of ON, the machine goes into the sub code entry standby mode.
    When [MODE SWITCH] key is pressed under the all ON state,  the mode is shifted to the individual
    ON mode, where the LEDs are turned on one by one from the left upper end to the left lower side
    then from the right upper side to the right lower side. (All the pixels of LCD are lighted simultaneously.)
    After lighting all the LCDs sequentially, all the LCDs are lighted simultaneously. After 5sec from light-
    ing all the LCDs simultaneously, the machine goes into the sub code entry standby mode. (Cycle of
    individual ON mode: ON 300ms, OFF 20ms)
    When [C] key is pressed in the LED check mode, the machine goes into the sub code entry standby
    mode.
    When [START] key is pressed, the machine goes into the key input check mode.
    
    When the machine goes into the key input check mode, the LCD displays 0.
    When any key is pressed after pressing a key on the operation panel, +1 is added to the value.
    Once a key is pressed, it is not recounted.
    When [START] key is pressed, counting is made and the machine goes into the LED ON check mode
    (LED all ON status) after 3sec.
    When [C] key is pressed for the first time, it is counted. When it is pressed for the second time, the
    machine goes into the sub code entry mode.
    When [CA] key is pressed for the first time, it is counted. When it is pressed for the second time, the
    machine goes out from the test command mode.
    (Note in the key input check mode)
    •Be sure to press [START] key at the last. (If it is pressed on the way, the machine goes into the LED
    ON check mode.) (LED all ON status)
    •Multi key input is ignored.
    [Operation]
    
    
    02 Fusing lamp, cooling fan 
    operation check (HT LAMP 
    CHK)[Function]
    When [OK (ENTER)/START] key is pressed, the fusing lamp repeats ON for 500ms and OFF for
    500ms 5 times. During this period, the cooling fan motor rotates.
    [Operation]
    03 Copy lamp ON check 
    (C-LAMP CHK)[Function]
    When [OK (ENTER)/START] key is pressed, the copy lamp turns ON for 5sec.
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    1) Initial display
    2) When [MODE SWITCH] key is pressed, the machine goes into the individual ON mode.
    
    
    1) Initial display 2) [OK (ENTER)/START]
    05-01 LCD/LED CHK.
                         005-01 LCD/LED CHK.
                        **
    1) Initial display
    05-02 HT LAMP CHK
    EXECUTING...
    1) Initial display
    05-03 C-LAMP CHK
    EXECUTING...
    e-STUDIO162_151.book  5 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 6 6 01 Paper feed solenoid 
    (CPFS1, CPFS2, MPFS) 
    operation check (PSOL 
    CHK)[Function]
    When [OK (ENTER)/START] key is pressed, the selected paper feed solenoid repeats ON for 500ms
    and OF for 500ms 20times.
    When [
    ←/→/10KEY] is pressed, the paper feed solenoid setting is switched.
    [Operation]
    02 Resist roller solenoid (RRS) 
    operation check (RES.R 
    SOL CHK)[Function]
    When [OK (ENTER)/START] key is pressed, the resist solenoid repeats ON for 500ms and OFF for
    500ms 20 times.
    [Operation]
    7 01 Check of warm-up display 
    and aging with JAM (W-UP/
    AGING)[Function]
    Copying is repeated to make the set quantity of copies.
    When the test command is executed, warm-up is started and warm-up time is added for every second
    from 0 and displayed.
    When warm-up is completed, addition is stopped. When [CA] key is pressed, the ready lamp lights up.
    After that, enter the copy quantity with [10KEY] and press [OK (ENTER)/START] key to repeat copy-
    ing of the set quantity (interval 0sec).
    To cancel the test command, turn off the power or execute a test command which causes hardware
    reset.
    [Operation]
    06 Interval aging (INTERVAL 
    AGING)[Function]
    Copying is repeated to make the set quantity of copies.
    When the test command is executed, warm-up is performed and the ready lamp is lighted.
    Enter the copy quantity with the [10KEY] and press [OK (ENTER)/START] key, and copying is exe-
    cuted to make the set quantity of copies, and the ready state is kept for 3sec, and copying is executed
    again to make the set quantity of copies. These operations are repeated.
    To cancel the test command, turn off the power or execute a test command which executes hardware
    reset.
    [Operation] 
    08 Shift to copy with warm-up 
    display (W-UP C-MODE)[Function]
    Enter the test command code, and warm-up is started and warm-up time is counted for every second
    from 0 and displayed.
    When [CA] key is pressed during counting up, 0 is displayed on the display and counting is stopped.
    However, warm-up is continued.
    After completion of warm-up, counting is terminated. (The aging function is removed from test com-
    mand 7-01.)
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    Code number Setting Remark
    0 CPFS1
    1 CPFS2 Operation is possible only when No. 2 cassette is installed. 
    2MPFS
    1) Initial display
    2) [
    →/10KEY]2) [
    ←/10KEY]
    3) [OK (ENTER)/START]
    4) Returns to the initial display.
    06-01 PSOL CHK
    0:CPFS1
    06-01 PSOL CHK
    1:CPFS206-01 PSOL CHK
    2:MPFS
    06-01 PSOL CHK
    EXECUTING...
    1) Initial display
    06-02 RES.R SOL CHK
    EXECUTING...
    1) Initial display 2) After 10sec
    07-01 W-UP/AGING
                        007-01 W-UP/AGING
                       10
    1) Initial display (Basic display of copy)
    READY TO COPY
      100%    A4     0
    1) Initial display 2) After 10sec
    07-08 W-UP C-MODE
                        007-08 W-UP C-MODE
                        10
    e-STUDIO162_151.book  6 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 7 8 01 Developing bias output 
    (DVLP BIAS SET.)[Function]
    When [OK (ENTER)/START] key is pressed, the developing bias signal is turned ON for 30sec.
    When, however, an actual output value is measured, use test command 25-01.
    After completion of this process, the machine goes into the sub code entry standby mode.
    [Operation]
    02 Main charger output (Grid 
    HIGH) (MHV(H) SET.)[Function]
    When [OK (ENTER)/START] key is pressed, the main charger is outputted for 30sec in the grid volt-
    age HIGH move.
    After completion of this process, the machine goes into the sub code entry standby mode. 
    [Operation]
    03 Main charger output (Grid 
    LOW) (MHV(L) SET.)[Function]
    When [OK (ENTER)/START] key is pressed, the main charger is outputted for 30sec in the grid volt-
    age LOW move.
    After completion of this process, the machine goes into the sub code entry standby mode.
    [Operation]
    06 Transfer charger output 
    (THV SET.)[Function]
    When [OK (ENTER)/START] key is pressed, the transfer charger is outputted for 30sec.
    After completion of this process, the machine goes into the sub code entry standby mode.
    [Operation]
    9 01 Duplex motor normal 
    rotation check (DPLX ROT.) 
    (Enabled when Duplex 
    setting is ON) (Executable 
    only when the RADF is 
    installed.)[Function]
    Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction) for
    30sec.
    After completion of this process, the machine goes into the sub code entry standby mode.
    [Operation]
    02 Duplex motor reverse 
    rotation check (DPLX 
    ROT.REV.) (Enabled when 
    Duplex setting is ON) 
    (Executable only when the 
    RADF is installed.)[Function]
    Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
    After completion of this process, the machine goes into the sub code entry standby mode.
    [Operation]
    04 Duplex motor rotating speed 
    adjustment (DPLX 
    ROT.SPEED) (Enabled 
    when Duplex setting is ON) 
    (Executable only when the 
    RADF is installed.)[Function]
    When this Test Command is executed, the currently set value is displayed.
    Enter the adjustment value with [10KEY] and press [START] key. The entered value is stored and the 
    machine goes into the sub code entry standby mode. The greater the set value is, the higher the 
    speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 8)
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    1) Initial display
    08-01 DVLP BIAS SET.
    EXECUTING...
    1) Initial display
    08-02 MHV(H) SET.
    EXECUTING...
    1) Initial display
    08-03 MHV(L) SET.
    EXECUTING...
    1) Initial display
    08-03 THV SET.
    EXECUTING...
    1) Initial display
    09-01 DPLX ROT.
    EXECUTING...
    1) Initial display
    09-02 DPLX ROT.REV.
    EXECUTING...
    1) Initial display 2) [10KEY] 3) [OK (ENTER)/START]
    09-04 DPLX ROT.SPEED
                8( 1-13)09-04 DPLX ROT.SPEED
                7( 1-13)09-04 DPLX ROT.SPEED
                7( 1-13)
    e-STUDIO162_151.book  7 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 8 10 00 Toner motor operation 
    (TONER MOTOR)[Function]
    When [OK (ENTER)/START] key is pressed, the toner motor is rotated for 30sec.
    After completion of this process, the machine goes into the main code entry standby mode.
    [Operation]
    14 00 Cancel of trouble other than 
    U2 (TRBL CANC.)[Function]
    Used to cancel troubles other than U2.
    ∗Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware reset. 
    [Operation]
    16 00 U2 trouble cancel (U2 TRBL 
    CANC.)[Function]
    Used to cancel U2 trouble.
    When [OK (ENTER)/START] key is pressed, check sum of the total counter in the EEPROM is rewrit-
    ten and hardware reset is made.
    [Operation]
    20 01 Maintenance counter clear 
    (M-CNT CLR.)[Function]
    When [OK (ENTER)/START] key is pressed, the maintenance count value is cleared and 000,000 is
    displayed.
    [Operation]
    21 01 Maintenance cycle setting 
    (M-CYCLE)[Function]
    The code of the currently set maintenance cycle value is displayed (initial display) and the set data 
    are saved.
    [Operation]
    22 01 Maintenance counter display 
    (M-CNT)[Function]
    The maintenance counter is displayed.
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    1) Initial display
    10-00 TONER MOTOR
    EXECUTING...
    1) Initial display
    14-00 TRBL CANC.
    CLEARED
    1) Initial display
    16-00 U2 TRBL CANC.
    CLEARED
    1) Initial display
    20-01 M-CNT CLR.
    CLEARED      000,000
    Code Setting Remark
    0 3,000 sheets
    1 6,000 sheets
    2 9,000 sheets
    3 13,000 sheets
    4 25,000 sheets Default
    5 Free (999,999 sheets)
    1) The current set value is
    displayed.2) [→/10KEY]
    2) [
    ←/10KEY]3) [OK (ENTER)/START]
    21-01 M-CYCLE
    4:25,000     ( 0-5 )
    21-01 M-CYCLE
    5:FREE       ( 0-5 )
    21-01 M-CYCLE
    3:13,000     ( 0-5 )21-01 M-CYCLE
    5:FREE       ( 0-5 )
    1) Initial display
    22-01 M-CNT
                 ***,***
    e-STUDIO162_151.book  8 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 9 22 02 Maintenance preset display 
    (M-CNT PRESET)[Function]
    The quantity (25,000 sheets, etc.) corresponding to the code set with TC21-01 is displayed.
    [Operation]
    04 JAM total counter display 
    (JAM TTL CNT)[Function]
    The JAM total counter is displayed.
    [Operation]
    05 Total counter display (TTL 
    CNT)[Function]
    The total counter value is displayed.
    [Operation]
    06 Developer counter display 
    (DVLP CNT)[Function]
    The developer counter data is acquired and displayed on the LCD.
    [Operation]
    08 ADF counter display (ADF 
    CNT) (Disabled when set to 
    OC) (Executable only when 
    the ADF is installed.)[Function]
    The ADF counter is displayed.
    [Operation]
    11 FAX-related counter display 
    (Executable only when the 
    FAX is installed.)[Function]
    The FAX-related counter is displayed.
    [Operation]
    12 Drum counter display 
    (DRUM CNT)[Function]
    The drum counter is displayed.
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    1) Initial display
    22-02 M-CNT PRESET
                 ***,***
    1) Initial display
    22-04 JAM TTL CNT
                 ***,***
    1) Initial display
    22-05 TTL CNT
                 ***,***
    1) Initial display
    22-06 DVLP CNT
                 ***,***
    1) Initial display
    22-08 ADF CNT
                  ***,***
    1) Initial display
    ∗[CLEAR] key: FAX control is terminated.
    2) Select 1
    (xxx,xxx is the current value.)
    ∗[CLEAR] key: Returns to 1) Initial display.2) Select 2
    (xxxx: xxx. xx is the current value.)∗[CLEAR] key: Returns to 1) Initial display.
    SELECT COUNTER
    1:PAGE     2:TIME
    SEND PAGE:xxx,xxx
    RECV PAGE:xxx,xxxTX TIME:xxxx:xx.xx
    RX TIME:xxxx:xx.xx
    1) Initial display
    22-12 DRUM CNT
                 ***,***
    e-STUDIO162_151.book  9 ページ  2004年12月2日 木曜日 午後9時37分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 10 22 14 ROM version display (ROM 
    VER.)[Function]
    The P-ROM version is displayed.
    Press [
    ←/→/10KEY] to switch the display version.
    [Operation]
    16 Duplex counter display 
    (DPLX CNT) (Enabled when 
    Duplex setting is ON) 
    (Executable only when the 
    RADF is installed.)[Function]
    The duplex counter is displayed.
    [Operation]
    17 Copy counter display 
    (COPIES CNT)[Function]
    The copy counter is displayed.
    [Operation]
    18 Printer counter display 
    (PRT.CNT)[Function]
    The printer counter is displayed.
    [Operation]
    19 Scanner mode counter 
    display (S-MODE CNT)[Function]
    The scanner mode counter is displayed.
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    Code number Version Display item
    0 Main unit Program MAIN PROG.
    1 F-IMC Program F-IMC PROG.
    2 LCD DATA LCD DATA
    1) Initial display 2) [→/10KEY]
    2) [
    ←/10KEY] 22-14 ROM VER.
    MAIN PROG.     00.00
    22-14 ROM VER.
    F-IMC PROG.    00.00
    22-14 ROM VER.
    LCD DATA       00.00
    1) Initial display
    22-16 DPLX CNT
                  ***,***
    1) Initial display
    22-17 COPIES CNT
                  ***,***
    1) Initial display
    22-18 PRT.CNT
                 ***,***
    1) Initial display
    22-19 S-MODE CNT
                  ***,***
    10_TESTCOMMAND.fm  10 ページ  2004年12月22日 水曜日 午後1時49分 
    						
    							e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 11 22 21 Scanner counter display 
    (SCAN CNT)[Function]
    The scanner counter is displayed.
    [Operation] 
    22 ADF JAM counter display (S 
    JAM CNT) (Disabled when 
    set to OC) (Executable only 
    when the ADF is installed.)[Function]
    The ADF JAM counter is displayed.
    [Operation]
    24 01 JAM total counter clear (JAM 
    TTL CLR.)[Function]
    When [OK (ENTER)/START] key is pressed, the JAM total counter is cleared to 0 and 000,000 is
    displayed on the LCD.
    [Operation]
    04 ADF counter clear (ADF 
    CLR.) (Disabled when set to 
    OC) (Executable only when 
    the ADF is installed.)[Function]
    When  [OK (ENTER)/START] key is pressed, the ADF counter value is cleared to 0 and 000,000 is
    displayed on the LCD.
    [Operation]
    05 Duplex counter clear (DPLX 
    CLR.) (Enabled when 
    Duplex setting is ON)[Function]
    When [OK (ENTER)/START] key is pressed, the duplex counter value is cleared to 0, and 000,000
    is displayed on the LCD.
    [Operation]
    06 Developer counter clear 
    (DVLP CLR.)[Function]
    When [OK (ENTER)/START] key is pressed, the developer counter value is cleared to 0, and
    000,000 is displayed on the LCD.
    [Operation]
    07 Drum counter clear (DRUM 
    CLR.)[Function]
    When [OK (ENTER)/START] key is pressed, the drum counter value is cleared to 0, and 000,000 is
    displayed on the LCD.
    [Operation]
    08 Copy counter clear (COPIES 
    CLR.)[Function]
    When [OK (ENTER)/START] key is pressed, the copy counter value is cleared to 0, and 000,000 is
    displayed on the LCD.
    [Operation] Main 
    codeSub 
    codeContents Details of function/operation
    1) Initial display
    22-21 SCAN CNT
                  ***,***
    1) Initial display
    22-22 S JAM CNT
                  ***,***
    1) Initial display
    24-01 JAM TTL CLR.
    CLEARED       000,000
    1) Initial display
    24-04 ADF CLR.
    CLEARED       000,000
    1) Initial display
    24-05 DPLX CLR.
    CLEARED       000,000
    1) Initial display
    24-06 DVLP CLR.
    CLEARED       000,000
    1) Initial display
    24-07 DRUM CLR.
    CLEARED       000,000
    1) Initial display
    24-08 COPIES CLR.
    CLEARED       000,000