e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 2 24 01 JAM total counter clear (JAM TTL CLR.) 04 ADF counter clear (ADF CLR.) (Disabled when set to OC) (Executable only when the ADF is installed.) 05 Duplex counter clear (DPLX CLR.) (Enabled when Duplex setting is ON) 06 Developer counter clear (DVLP CLR.) 07 Drum counter clear (DRUM CLR.) 08 Copy counter clear (COPIES CLR.) 09 Printer counter clear (PRT.CLR.) 10 FAX counter clear (FAX CLR.) (Executable only when the FAX is installed.) 13 Scanner counter clear (SCAN CLR.) 14 ADF JAM total counter clear (S JAM TTL CLR.) (Disabled when set to OC) (Executable only when the ADF is installed.) 15 Scanner mode counter clear (S-MODE CLR.) 25 01 Main motor operation check (MAIN MOTOR CHK) 10 Polygon motor operation check (LSU CHK) 26 02 (R)ADF setting (ADF/RADF) (Executable only when the ADF/RADF is installed.) 03 Second cassette setting (2ND TRAY) 04 Main unit duplex setting (DPLX) (Executable only when the RADF is installed.) 06 Destination setting (DESTINATION) 07 Machine conditions check (CPM) 20 Rear edge void setting (END EDGE) 30 CE mark support control ON/OFF (CE MARK) 37 Cancel of stop at developer life over (DVLP LIFE END) 39 Memory capacity check (MEM.CHK) 40 Polygon motor OFF time setting (Time required from completion of printing to turning OFF the motor) (LSU MOTOR OFF) 42 Transfer ON timing control setting (TC ON TIMING) 43 Side void amount setting (SIDE VOID) 62 Energy-save mode copy lamp setting (C-LAMP E-S) 30 01 Paper sensor status display (P-SENSOR) 41 06 OC cover float detection level (OC FLOAT LEVEL) (Disabled when set to OC) (Executable only when the ADF/RADF is installed.) 43 01 Fusing temperature setting (Normal copy) (FU TEMP) 04 Fusing temperature setting in multi coy (FU TEMP MULTI) 05 Fusing temperature setting in duplex copy (FU TEMP DPLX) (Enabled when Duplex setting is ON) 14 Fusing start temperature setting (FU TEMP START) 46 01 Copy density adjustment (300dpi) (EXP.LEVEL 300) 02 Copy density adjustment (600dpi) (EXP.LEVEL 600) 12 Density adjustment in the FAX mode (Collective adjustment) (Executable only when the FAX is installed.) 13 FAX mode density adjustment (normal text) (Executable only when the FAX is installed.) 14 FAX mode density adjustment (Fine text) (Executable only when the FAX is installed.) 15 FAX mode density adjustment (Super fine) (Executable only when the FAX is installed.) 18 Image contrast adjustment (300dpi) (GAMMA 300) 19 Exposure mode setting (AE MODE) 20 ADF exposure correction (EXP.LEVEL ADF) (Disabled when set to OC) (Executable only when the ADF is installed.) 29 Image contrast adjustment (600dpi) (GAMMA 600) 30 AE limit adjustment (AE LIMIT) 31 Image sharpness adjustment (SHARPNESS) Main codeSub codeContents 46 32 Copier color reproduction setting (COLOR REAPPEAR) 39 FAX mode sharpness adjustment (Executable only when the FAX is installed.) 48 01 Mains can/sub scan direction magnification ratio (COPY MAG.) 05 ADF/RADF mode sub scan direction magnification ratio in copying (ADF/RADF MAG.) (Disabled when set to OC) (Executable only when the ADF/RADF is installed.) 49 01 Download mode (DOWNLOAD MODE) 50 01 Lead edge image position (LEAD EDGE) 06 Copy lead edge position adjustment (ADF/RADF) (ADF/ RADF EDGE) (Disabled when set to OC) (Executable only when the ADF/RADF is installed.) 10 Print center offset adjustment (PRT.OFF-CENTER) 12 Document feed off-center adjustment (ORG.OFF- CENTER) 18 Memory reverse position adjustment in duplex copy (DPLX REVERSE) (Enabled when Duplex setting is ON with OC or ADF set) (Executable only when the RADF is installed.) 19 Duplex copy rear edge void adjustment (DPLX END EDGE) (Enabled when Duplex setting is ON) (Executable only when the RADF is installed.) 51 02 Resist amount adjustment (RESIST ADJ.) 53 08 ADF scan position automatic adjustment (ADF AUTO) (Disabled when set to OC) (Executable only when the ADF is installed.) 61 03 HSYNC output check (LSU CHK) 63 01 Shading check (SHADING CHK) 02 Black level automatic correction (BLACK LEVEL) 64 01 Self print (1by2 mode) (SELF PRT.) 66 01 FAX soft SW setting (Executable only when the FAX is installed.) 02 FAX soft SW initializing (excluding the adjustment values) (Executable only when the FAX is installed.) 03 FAX PWB memory check (Executable only when the FAX is installed.) 04 Signal send mode (Max. value) (Executable only when the FAX is installed.) 05 Signal send mode (Soft SW set value) (Executable only when the FAX is installed.) 07 Image memory content print (Executable only when the FAX is installed.) 10 Image memory content clear (Executable only when the FAX is installed.) 11 300bps signal send (Max. value) (Executable only when the FAX is installed.) 12 300bps signal send (Soft SW set value) (Executable only when the FAX is installed.) 13 Dial test (Executable only when the FAX is installed.) 17 DTMF signal send (Max. value) (Executable only when the FAX is installed.) 18 DTMF signal send (Soft SW set value) (Executable only when the FAX is installed.) 21 FAX information print (Executable only when the FAX is installed.) 24 FAST SRAM clear (Executable only when the FAX is installed.) 30 TEL/LIU status change check (Executable only when the FAX is installed.) 32 Receive data check (Executable only when the FAX is installed.) 33 Signal detection check (Executable only when the FAX is installed.) Main codeSub codeContents e-STUDIO162_151.book 2 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 3 4. Descriptions of various test commands 66 34 Communication time measurement (Executable only when the FAX is installed.) 37 Speaker sound volume setting (Executable only when the FAX is installed.) 38 Time setting/check (Executable only when the FAX is installed.) 41 CI signal check (Executable only when the FAX is installed.) Main codeSub codeContents Main codeSub codeContents Details of function/operation 1 01 Mirror scan (SCAN CHK)[Function] When [OK (ENTER)/START] key is pressed, the home position is checked and the mirror base per- forms full scan at the speed of the set magnification ratio. During operation, the set magnification ratio is displayed. The mirror home position sensor status is displayed with the “COPY mode lamp”. (When the mirror is in the home position, the lamp lights up.) During operation, the copy lamp lights up. When [C] key is pressed, if the operation is on the way, it is terminated and the machine goes to the sub code entry standby mode. [Operation] 02 Mirror home position sensor (MHPS) status display (MHP-SENSOR)[Function] Monitors the mirror home position sensor, and makes the COPY mode lamp turn on during the sen- sor ON status. [Operation] 06 Mirror scan aging (SCAN AGING)[Function] When [OK (ENTER)/START] key is pressed, the mirror base performs full scan at the speed of the set magnification ratio. During operation, the set magnification ratio is displayed. After 3sec, the mirror base performs full scan again. ∗When [OK (ENTER)/START] key is pressed once, the ready lamp remains OFF. The mirror home position sensor status is displayed on the COPY mode lamp. (The lamp is ON when the mirror is in the home position.) During aging, the copy lamp is ON. [Operation] The operation is similar to test command 1-01. 2 01 Single Paper Feeder (ADF) aging (ADF AGING) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] When [OK (ENTER)/START] key is pressed, the set magnification ratio is acquired and single-face document transport is performed in the case of ADF or duplex document transport in the case of R- ADF. However, the operating conditions dont matter and the operation is not stopped even in case of a jam. Also the magnification ratio is displayed on the LCD. [Operation] The operation is similar to test command 1-01. 1) Initial display 2) [ZOOM]2) [←] 2) [ →]3) [OK (ENTER)/START] 01-01 SCAN CHK - 100% + 01-01 SCAN CHK - 78% +01-01 SCAN CHK - 99% + 01-01 SCAN CHK - 101% +01-01 SCAN CHK EXECUTING... - 78% + 1) Initial display 01-02 MHP-SENSOR EXECUTING... e-STUDIO162_151.book 3 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 4 2 02 ADF sensor status display (ADF SENSOR) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] The ON/OFF status of the ADF sensors can be checked with the LCD. When a sensor is ON, the sensor name is displayed on the LCD. [Operation] 03 ADF motor operation check (ADF MOTOR CHK) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] When [OK (ENTER)/START] key is pressed, the motor rotates for 10sec at the speed corresponding to the set magnification ratio. [Operation] The operation is similar to test command 1-01. 06 RADF resist clutch operation check (RADF RES.CHK) (Enabled only when RADF is set.) (Executable only when the RADF is installed.)[Function] When [OK (ENTER)/START] key is pressed, the RADF resist clutch (SRRC) repeats ON for 500ms and OFF for 500ms 20 times. [Operation] 08 ADF paper feed solenoid operation check (ADF SPUS CHK) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] The ADF paper feed solenoid (SPUS) repeats ON for 500ms and OFF for 500ms 20 times by the use of the solenoid drive control Bios. [Operation] 09 RADF reverse solenoid operation check (RADF SPFS CHK) (Enabled only when RADF is set.) (Executable only when the RADF is installed.)[Function] The ADF reverse solenoid (SPFS) repeats ON for 500ms and OFF for 500ms 20 times by the use of the solenoid drive control Bios. [Operation] 10 RADF paper exit gate solenoid operation check (RADF SGS CHK) (Enabled only when RADF is set.) (Executable only when the RADF is installed.)[Function] The ADF paper exit gate solenoid (SGS) repeats ON for 500ms and OFF for 500ms 20 times by the use of the solenoid drive control Bios. [Operation] 3 03 Shifter operation check (SHIFTER CHK)[Function] The shifter is moved back and forth in four reciprocations. [Operation] Main codeSub codeContents Details of function/operation Sensor Display item Document set sensor SPID ADF document transport sensor SPPD ADF paper feed cover open/close sensor SDSW 1) Initial display 2) When the sensor is ON: 02-02 ADF SENSOR02-02 ADF SENSOR SPID SPPD SDSW 1) Initial display 02-06 RADF RES.CHK EXECUTING... 1) Initial display 02-08 ADF SPUS CHK EXECUTING... 1) Initial display 02-09 RADF SPFS CHK EXECUTING... 1) Initial display 02-10 RADF SGS CHK EXECUTING... 1) Initial display 03-03 SHIFTER CHK EXECUTING... e-STUDIO162_151.book 4 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 5 5 01 Operation panel display check (LCD/LED CHK)[Function] When [OK (ENTER)/START] key is pressed, all the LCDs on the operation panel are turned ON (all pixels ON). After 5sec of ON, the machine goes into the sub code entry standby mode. When [MODE SWITCH] key is pressed under the all ON state, the mode is shifted to the individual ON mode, where the LEDs are turned on one by one from the left upper end to the left lower side then from the right upper side to the right lower side. (All the pixels of LCD are lighted simultaneously.) After lighting all the LCDs sequentially, all the LCDs are lighted simultaneously. After 5sec from light- ing all the LCDs simultaneously, the machine goes into the sub code entry standby mode. (Cycle of individual ON mode: ON 300ms, OFF 20ms) When [C] key is pressed in the LED check mode, the machine goes into the sub code entry standby mode. When [START] key is pressed, the machine goes into the key input check mode. When the machine goes into the key input check mode, the LCD displays 0. When any key is pressed after pressing a key on the operation panel, +1 is added to the value. Once a key is pressed, it is not recounted. When [START] key is pressed, counting is made and the machine goes into the LED ON check mode (LED all ON status) after 3sec. When [C] key is pressed for the first time, it is counted. When it is pressed for the second time, the machine goes into the sub code entry mode. When [CA] key is pressed for the first time, it is counted. When it is pressed for the second time, the machine goes out from the test command mode. (Note in the key input check mode) •Be sure to press [START] key at the last. (If it is pressed on the way, the machine goes into the LED ON check mode.) (LED all ON status) •Multi key input is ignored. [Operation] 02 Fusing lamp, cooling fan operation check (HT LAMP CHK)[Function] When [OK (ENTER)/START] key is pressed, the fusing lamp repeats ON for 500ms and OFF for 500ms 5 times. During this period, the cooling fan motor rotates. [Operation] 03 Copy lamp ON check (C-LAMP CHK)[Function] When [OK (ENTER)/START] key is pressed, the copy lamp turns ON for 5sec. [Operation] Main codeSub codeContents Details of function/operation 1) Initial display 2) When [MODE SWITCH] key is pressed, the machine goes into the individual ON mode. 1) Initial display 2) [OK (ENTER)/START] 05-01 LCD/LED CHK. 005-01 LCD/LED CHK. ** 1) Initial display 05-02 HT LAMP CHK EXECUTING... 1) Initial display 05-03 C-LAMP CHK EXECUTING... e-STUDIO162_151.book 5 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 6 6 01 Paper feed solenoid (CPFS1, CPFS2, MPFS) operation check (PSOL CHK)[Function] When [OK (ENTER)/START] key is pressed, the selected paper feed solenoid repeats ON for 500ms and OF for 500ms 20times. When [ ←/→/10KEY] is pressed, the paper feed solenoid setting is switched. [Operation] 02 Resist roller solenoid (RRS) operation check (RES.R SOL CHK)[Function] When [OK (ENTER)/START] key is pressed, the resist solenoid repeats ON for 500ms and OFF for 500ms 20 times. [Operation] 7 01 Check of warm-up display and aging with JAM (W-UP/ AGING)[Function] Copying is repeated to make the set quantity of copies. When the test command is executed, warm-up is started and warm-up time is added for every second from 0 and displayed. When warm-up is completed, addition is stopped. When [CA] key is pressed, the ready lamp lights up. After that, enter the copy quantity with [10KEY] and press [OK (ENTER)/START] key to repeat copy- ing of the set quantity (interval 0sec). To cancel the test command, turn off the power or execute a test command which causes hardware reset. [Operation] 06 Interval aging (INTERVAL AGING)[Function] Copying is repeated to make the set quantity of copies. When the test command is executed, warm-up is performed and the ready lamp is lighted. Enter the copy quantity with the [10KEY] and press [OK (ENTER)/START] key, and copying is exe- cuted to make the set quantity of copies, and the ready state is kept for 3sec, and copying is executed again to make the set quantity of copies. These operations are repeated. To cancel the test command, turn off the power or execute a test command which executes hardware reset. [Operation] 08 Shift to copy with warm-up display (W-UP C-MODE)[Function] Enter the test command code, and warm-up is started and warm-up time is counted for every second from 0 and displayed. When [CA] key is pressed during counting up, 0 is displayed on the display and counting is stopped. However, warm-up is continued. After completion of warm-up, counting is terminated. (The aging function is removed from test com- mand 7-01.) [Operation] Main codeSub codeContents Details of function/operation Code number Setting Remark 0 CPFS1 1 CPFS2 Operation is possible only when No. 2 cassette is installed. 2MPFS 1) Initial display 2) [ →/10KEY]2) [ ←/10KEY] 3) [OK (ENTER)/START] 4) Returns to the initial display. 06-01 PSOL CHK 0:CPFS1 06-01 PSOL CHK 1:CPFS206-01 PSOL CHK 2:MPFS 06-01 PSOL CHK EXECUTING... 1) Initial display 06-02 RES.R SOL CHK EXECUTING... 1) Initial display 2) After 10sec 07-01 W-UP/AGING 007-01 W-UP/AGING 10 1) Initial display (Basic display of copy) READY TO COPY 100% A4 0 1) Initial display 2) After 10sec 07-08 W-UP C-MODE 007-08 W-UP C-MODE 10 e-STUDIO162_151.book 6 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 7 8 01 Developing bias output (DVLP BIAS SET.)[Function] When [OK (ENTER)/START] key is pressed, the developing bias signal is turned ON for 30sec. When, however, an actual output value is measured, use test command 25-01. After completion of this process, the machine goes into the sub code entry standby mode. [Operation] 02 Main charger output (Grid HIGH) (MHV(H) SET.)[Function] When [OK (ENTER)/START] key is pressed, the main charger is outputted for 30sec in the grid volt- age HIGH move. After completion of this process, the machine goes into the sub code entry standby mode. [Operation] 03 Main charger output (Grid LOW) (MHV(L) SET.)[Function] When [OK (ENTER)/START] key is pressed, the main charger is outputted for 30sec in the grid volt- age LOW move. After completion of this process, the machine goes into the sub code entry standby mode. [Operation] 06 Transfer charger output (THV SET.)[Function] When [OK (ENTER)/START] key is pressed, the transfer charger is outputted for 30sec. After completion of this process, the machine goes into the sub code entry standby mode. [Operation] 9 01 Duplex motor normal rotation check (DPLX ROT.) (Enabled when Duplex setting is ON) (Executable only when the RADF is installed.)[Function] Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction) for 30sec. After completion of this process, the machine goes into the sub code entry standby mode. [Operation] 02 Duplex motor reverse rotation check (DPLX ROT.REV.) (Enabled when Duplex setting is ON) (Executable only when the RADF is installed.)[Function] Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec. After completion of this process, the machine goes into the sub code entry standby mode. [Operation] 04 Duplex motor rotating speed adjustment (DPLX ROT.SPEED) (Enabled when Duplex setting is ON) (Executable only when the RADF is installed.)[Function] When this Test Command is executed, the currently set value is displayed. Enter the adjustment value with [10KEY] and press [START] key. The entered value is stored and the machine goes into the sub code entry standby mode. The greater the set value is, the higher the speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 8) [Operation] Main codeSub codeContents Details of function/operation 1) Initial display 08-01 DVLP BIAS SET. EXECUTING... 1) Initial display 08-02 MHV(H) SET. EXECUTING... 1) Initial display 08-03 MHV(L) SET. EXECUTING... 1) Initial display 08-03 THV SET. EXECUTING... 1) Initial display 09-01 DPLX ROT. EXECUTING... 1) Initial display 09-02 DPLX ROT.REV. EXECUTING... 1) Initial display 2) [10KEY] 3) [OK (ENTER)/START] 09-04 DPLX ROT.SPEED 8( 1-13)09-04 DPLX ROT.SPEED 7( 1-13)09-04 DPLX ROT.SPEED 7( 1-13) e-STUDIO162_151.book 7 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 8 10 00 Toner motor operation (TONER MOTOR)[Function] When [OK (ENTER)/START] key is pressed, the toner motor is rotated for 30sec. After completion of this process, the machine goes into the main code entry standby mode. [Operation] 14 00 Cancel of trouble other than U2 (TRBL CANC.)[Function] Used to cancel troubles other than U2. ∗Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware reset. [Operation] 16 00 U2 trouble cancel (U2 TRBL CANC.)[Function] Used to cancel U2 trouble. When [OK (ENTER)/START] key is pressed, check sum of the total counter in the EEPROM is rewrit- ten and hardware reset is made. [Operation] 20 01 Maintenance counter clear (M-CNT CLR.)[Function] When [OK (ENTER)/START] key is pressed, the maintenance count value is cleared and 000,000 is displayed. [Operation] 21 01 Maintenance cycle setting (M-CYCLE)[Function] The code of the currently set maintenance cycle value is displayed (initial display) and the set data are saved. [Operation] 22 01 Maintenance counter display (M-CNT)[Function] The maintenance counter is displayed. [Operation] Main codeSub codeContents Details of function/operation 1) Initial display 10-00 TONER MOTOR EXECUTING... 1) Initial display 14-00 TRBL CANC. CLEARED 1) Initial display 16-00 U2 TRBL CANC. CLEARED 1) Initial display 20-01 M-CNT CLR. CLEARED 000,000 Code Setting Remark 0 3,000 sheets 1 6,000 sheets 2 9,000 sheets 3 13,000 sheets 4 25,000 sheets Default 5 Free (999,999 sheets) 1) The current set value is displayed.2) [→/10KEY] 2) [ ←/10KEY]3) [OK (ENTER)/START] 21-01 M-CYCLE 4:25,000 ( 0-5 ) 21-01 M-CYCLE 5:FREE ( 0-5 ) 21-01 M-CYCLE 3:13,000 ( 0-5 )21-01 M-CYCLE 5:FREE ( 0-5 ) 1) Initial display 22-01 M-CNT ***,*** e-STUDIO162_151.book 8 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 9 22 02 Maintenance preset display (M-CNT PRESET)[Function] The quantity (25,000 sheets, etc.) corresponding to the code set with TC21-01 is displayed. [Operation] 04 JAM total counter display (JAM TTL CNT)[Function] The JAM total counter is displayed. [Operation] 05 Total counter display (TTL CNT)[Function] The total counter value is displayed. [Operation] 06 Developer counter display (DVLP CNT)[Function] The developer counter data is acquired and displayed on the LCD. [Operation] 08 ADF counter display (ADF CNT) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] The ADF counter is displayed. [Operation] 11 FAX-related counter display (Executable only when the FAX is installed.)[Function] The FAX-related counter is displayed. [Operation] 12 Drum counter display (DRUM CNT)[Function] The drum counter is displayed. [Operation] Main codeSub codeContents Details of function/operation 1) Initial display 22-02 M-CNT PRESET ***,*** 1) Initial display 22-04 JAM TTL CNT ***,*** 1) Initial display 22-05 TTL CNT ***,*** 1) Initial display 22-06 DVLP CNT ***,*** 1) Initial display 22-08 ADF CNT ***,*** 1) Initial display ∗[CLEAR] key: FAX control is terminated. 2) Select 1 (xxx,xxx is the current value.) ∗[CLEAR] key: Returns to 1) Initial display.2) Select 2 (xxxx: xxx. xx is the current value.)∗[CLEAR] key: Returns to 1) Initial display. SELECT COUNTER 1:PAGE 2:TIME SEND PAGE:xxx,xxx RECV PAGE:xxx,xxxTX TIME:xxxx:xx.xx RX TIME:xxxx:xx.xx 1) Initial display 22-12 DRUM CNT ***,*** e-STUDIO162_151.book 9 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 10 22 14 ROM version display (ROM VER.)[Function] The P-ROM version is displayed. Press [ ←/→/10KEY] to switch the display version. [Operation] 16 Duplex counter display (DPLX CNT) (Enabled when Duplex setting is ON) (Executable only when the RADF is installed.)[Function] The duplex counter is displayed. [Operation] 17 Copy counter display (COPIES CNT)[Function] The copy counter is displayed. [Operation] 18 Printer counter display (PRT.CNT)[Function] The printer counter is displayed. [Operation] 19 Scanner mode counter display (S-MODE CNT)[Function] The scanner mode counter is displayed. [Operation] Main codeSub codeContents Details of function/operation Code number Version Display item 0 Main unit Program MAIN PROG. 1 F-IMC Program F-IMC PROG. 2 LCD DATA LCD DATA 1) Initial display 2) [→/10KEY] 2) [ ←/10KEY] 22-14 ROM VER. MAIN PROG. 00.00 22-14 ROM VER. F-IMC PROG. 00.00 22-14 ROM VER. LCD DATA 00.00 1) Initial display 22-16 DPLX CNT ***,*** 1) Initial display 22-17 COPIES CNT ***,*** 1) Initial display 22-18 PRT.CNT ***,*** 1) Initial display 22-19 S-MODE CNT ***,*** 10_TESTCOMMAND.fm 10 ページ 2004年12月22日 水曜日 午後1時49分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 11 22 21 Scanner counter display (SCAN CNT)[Function] The scanner counter is displayed. [Operation] 22 ADF JAM counter display (S JAM CNT) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] The ADF JAM counter is displayed. [Operation] 24 01 JAM total counter clear (JAM TTL CLR.)[Function] When [OK (ENTER)/START] key is pressed, the JAM total counter is cleared to 0 and 000,000 is displayed on the LCD. [Operation] 04 ADF counter clear (ADF CLR.) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] When [OK (ENTER)/START] key is pressed, the ADF counter value is cleared to 0 and 000,000 is displayed on the LCD. [Operation] 05 Duplex counter clear (DPLX CLR.) (Enabled when Duplex setting is ON)[Function] When [OK (ENTER)/START] key is pressed, the duplex counter value is cleared to 0, and 000,000 is displayed on the LCD. [Operation] 06 Developer counter clear (DVLP CLR.)[Function] When [OK (ENTER)/START] key is pressed, the developer counter value is cleared to 0, and 000,000 is displayed on the LCD. [Operation] 07 Drum counter clear (DRUM CLR.)[Function] When [OK (ENTER)/START] key is pressed, the drum counter value is cleared to 0, and 000,000 is displayed on the LCD. [Operation] 08 Copy counter clear (COPIES CLR.)[Function] When [OK (ENTER)/START] key is pressed, the copy counter value is cleared to 0, and 000,000 is displayed on the LCD. [Operation] Main codeSub codeContents Details of function/operation 1) Initial display 22-21 SCAN CNT ***,*** 1) Initial display 22-22 S JAM CNT ***,*** 1) Initial display 24-01 JAM TTL CLR. CLEARED 000,000 1) Initial display 24-04 ADF CLR. CLEARED 000,000 1) Initial display 24-05 DPLX CLR. CLEARED 000,000 1) Initial display 24-06 DVLP CLR. CLEARED 000,000 1) Initial display 24-07 DRUM CLR. CLEARED 000,000 1) Initial display 24-08 COPIES CLR. CLEARED 000,000 e-STUDIO162_151.book 11 ページ 2004年12月2日 木曜日 午後9時37分