Home > Toshiba > Copier > Toshiba Estudio 162 Owners Manual

Toshiba Estudio 162 Owners Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Estudio 162 Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							e-STUDIO162/162D/151/151D CIRCUIT DIAGRAM  14 - 35
    10
    22 18 161
    239 2
    8
    213
    20
    24 176
    MCU
    PWB
    CN16
    145
    12
    154
    11
    137
    191
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    26 25 MDM_IRQ
    PB_NAE0
    PB_ADDR1
    PB_ADDR6
    PB_DATA1
    PB_DATA5
    PB_DATA7 PB_ADDR5
    PB_DATA0
    PB_DATA4 D-GND
    PB_MOE
    PB_NWE
    D-GND
    PB_ADDR0
    PB_ADDR3
    D-GND (/FAX_RST)
    PB_NCS1
    PB_ADDR2
    PB_ADDR4
    PB_ADDR7
    D-GND
    PB_DATA2
    PB_DATA3
    PB_DATA6CN37
    5
    D7 D-GND
    17 EN5V
    D-GND16 D1
    D4
    15
    18 VCC3
    19 14
    D-GND D3
    MSU_ST1 2
    D0
    VCC36
    129 /RD
    P-GND D23
    MODEM_IN
    24V4
    208 7 CN38
    13 D5 /CS4
    D61
    11 10
    Personal Computer (IEEE1284 port)
    TO TEL
    DIR3
    P3 /PACK PBSY
    P0 P4
    D-GND P2 PERR
    5V P6 /STB
    /FLT /IT3
    /SELIN3
    P7 /AFEED3 D-GND
    VCC3 P1
    /RESETSLCT
    5V P5MDM_IRQ
    PB_NAE0
    PB_ADDR1
    PB_ADDR6
    PB_DATA1
    PB_DATA5
    PB_DATA7 PB_ADDR5
    PB_DATA0
    PB_DATA4 D-GND
    PB_MOE
    PB_NWE
    D-GND
    PB_ADDR0
    PB_ADDR3
    D-GND (/FAX_RST)
    PB_NCS1
    PB_ADDR2
    PB_ADDR4
    PB_ADDR7
    D-GND
    PB_DATA2
    PB_DATA3
    PB_DATA6
    FA X
    PWB
    24
    18 20 26
    25
    23
    22
    21
    19
    17
    6 7
    4 12
    9 16
    5
    3 8 10 14 15
    13
    11
    2
    1VOUT1
    VOUT2CN10
    D7 D-GND
    EN5V
    D-GND D1
    D4
    VCC3 D-GND D3 MSU_ST1
    D0
    VCC3 /RD
    P-GND D2 MODEM_IN
    24V D5 /CS4
    D6 10
    8
    7
    2 5 13
    9 19
    18
    14
    4 6 17 20
    1 3 11 16
    15
    12CN2
    1
    2
    SPEAKER
    CN1
    OPTIONAL
    1
    2
    3
    45V USB
    D ATA  + D ATA  -
    D-GNDCN33
    Personal Computer(USB PORT)
    (3) I/F & FAX (Optional) SECTION (3/3)
    14_CIRCUTDIAGRAM.fm  35 ページ  2004年12月2日 木曜日 午後7時16分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 1
    [15] FIRMWARE DOWNLOAD 
    PROCEDURES
    [Preparation]
    Write the download data (extension .dwl) into the main unit.
    A USB port is required for the PC.
    Create MaintenanceTool  flooder in the PC, and copy the following
    files to the folder.
    Necessary for program download
    • Maintenance.exe (← Tool program)
     ProcModelB.mdl
     ProcModelC.mdl
     ProcModelE.fmt
     ProcModelE.ini
     ProcModelE.mdl
    Driver
     Drivers/2kXP/Mainte.inf (For Windows XP/2000)
     Drivers/Win9xME/Mainte.inf (For Windows Me/98SE)
     Drivers/Win9xME/UsbScan.sys (For Windows Me/98SE)
    Download file
     Download file (extension .dwl)
    Note: Copy the download data file (extension .dwl) to the folder in
    which the maintenance program is included.
    When making a folder for the maintenance tool in the PC, do not
    put a long folder name in the absolute path.
    [Example]
    Erroneous case: c:\Mainte nance Tool Download
    Proper case: c:\MaintenanceTool
    1. Initial setting 
    (Serial number setting procedures)
    The serial number is set to the PC which is used for downloading. Set-
    ting is required once only, and there is no need to set again when
    rebooting the program.
    Note: This setting is required only when downloading the default data
    of E2PROM, and is not required when downloading firmware
    only.
    1) PC side: Boot Maintenance.exe and select e-STUDIO162/151
    series in the Select Model menu.
    (Only to set the serial number, the PC should not be connected to
    the machine.)2) Select Option 
    → Serial Number Setting on the menu bar.
    3) Set the serial number according to the following.
    After completion setting, press [OK] key.
    4) The serial number has been assigned.
    2. Download procedures
    1) Main unit side: Execute Test command No. 49-01 (Flash ROM pro-
    gram write mode).
    Check that DOWNLOAD MODE is displayed on the LCD of the
    operation panel. (Press and hold [CA] key and [DOWN] key (left
    key) together, and turn on the power simultaneously.)
    2) Connect machine and the PC with a USB cable. (Connect it to the
    USB port on the main unit without fail.
    3) PC side: Boost Maintenance.exe and select e-STUDIO162/151
    series in the Select Model menu.
    Product Code (P): Enter number (0 – 99)
    Enter the product code of “3.”
    ID Code(I): Enter number (0 – 99)
    Assign an individual code to each PC uses
    “Maintenance.exe.”
    e-STUDIO162_151.book  1 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 2 4) PC side: Check that the Simulation Command List tree is dis-
    played on the integration maintenance program.
    5) PC side: When the integration maintenance program is boosted
    and The copier is not turned on. is displayed at the bottom of dis-
    play, select File 
    → Reconnect on the menu bar.
    6) PC side: Check that trees are displayed in the Special (MCU/
    IMC2/Facsimile) folder in the integration maintenance program. (If
    trees are not displayed, check that the USB connector is con-
    nected, and select Reconnect in procedure 5) again.)
    7) PC side: Double-click Special (MCU/IMC2/Facsimile) in the main
    tree to develop its sub trees, and double-click Download DWL
    Data Area in the sub trees.8) PC side: Specify the download file (*****.dwl) to be used.
    9) PC side: When a download file is specified, downloading is per-
    formed automatically.
    10) PC side: When download is completed, the following message is
    displayed.
    Note: Since, however, the machine enters the download data write
    state, do not turn OFF the power of the machine at this moment.
    11) Main unit side: Wait until DOWNLOAD COMPLETE! is displayed
    on the LCD of the operation panel. When DOWNLOAD COM-
    PLETE! is displayed, download is completed.
    Turn OFF the power of the machine, and disconnect the USB
    cable.
    12) Terminate the integration maintenance program, and turn ON the
    machine again.
    Download is completed with the above procedures.
    e-STUDIO162_151.book  2 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 3 Note: When another machine is connected, connect the USB cable
    again and select File 
    → Reconnect on the menu bar of the
    integration maintenance program. Repeat the above procedures
    from 5).
    ∗
    ∗∗ ∗Inhibition during download (Important)
    If download is failed, the next download may not be executed. Use
    great care not to execute the following items during download.
    Never turn off the machine.
    Never disconnect the download cable (USB cable).
    * If the above inhibition item occurs during downloading, 
    turn OFF/ON the power.
    1) When DOWNLOAD MODE is displayed on the operation panel,
    execute the download procedure again.
    2) If DOWNLOAD MODE is not displayed on the operation panel,
    turn OFF the power and press and hold [CA] key and [DOWN] key
    (left key) and turn ON the power. Check that DOWNLOAD MODE
    is displayed on the operation panel, and execute the download pro-
    cedure again.
    If DOWNLOAD MODE is not still displayed, replace the MCU with
    a new one.
    3. Version acquisition procedures
    1) Main unit side:  Execute Test command No. 49-01 (Flash ROM pro-
    gram write mode).
    Check that DOWNLOAD MODE is displayed on the operation
    panel of the main unit. (Press and hold [CA] key and [DOWN] key
    (left key) together, and turn on the power simultaneously.)
    2) Connect the machine and the PC with a USB cable.
    3) PC side: Boost Maintenance.exe and select e-STUDIO162/151
    series in the Select Model menu.4) PC side: Check that the Simulation Command List tree on the
    integration maintenance program.
    5) PC side: Boot the integration maintenance program. If The copier
    is not turned on. is displayed, select File 
    → Reconnect on the
    menu bar.
    6) PC side: Check that trees are displayed on Special (MCU/IMC2/
    Facsimile in the integration maintenance program. (If trees are not
    displayed, check that the USB cable is connected and select
    Reconnect again in procedure 5).
    e-STUDIO162_151.book  3 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 4 7) PC side: Double-click Special (MCU/IMC2/Facsimile) in the main
    tree items to develop its sub trees. Select Get Version in the sub
    trees.
    8) Check that the following display is shown.
    With the above procedures, version acquisition is completed.
    The display of **.** means its version is not downloaded. The
    downloaded versions are displayed in a version number as shown in
    “MCU Boot Version” and “MCU program Version”.
    4. EEPROM data acquisition procedure
    EEPROM data is acquired to the PC. Use this procedure as data main-
    tenance of EEPROM.
    1) Main unit side: Execute Test command No. 49-01 (Flash ROM pro-
    gram write mode). 
    Check that DOWNLOAD MODE is displayed on the operation
    panel of the main unit. (Press and hold [CA] key and [DOWN] key
    (left key) together, and turn on the power simultaneously.)
    2) Connect the machine and the PC with a USB cable.
    3) PC side: Boot Maintenance.exe and select e-STUDIO162/151
    series in the Select Model menu.4) PC side: Check that Simulation Command List tree is displayed in
    the integration maintenance program.
    5) PC side: Boot the integration maintenance program. If The copier
    is not turned on. is displayed on the lower side of the display,
    select File 
    → Reconnect on the menu bar.
    6) PC side: Check that trees are displayed on Special (MCU/IMC2/
    Facsimile in the integration maintenance program. (If trees are not
    displayed, check that the USB cable is connected and select
    Reconnect again in procedure 5).
    e-STUDIO162_151.book  4 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 5 7) PC side: Double-click Special (MCU/IMC2/Facsimile) to develop
    its sub trees, and select Upload EEPROM Data Area in the sub
    trees.
    8) PC side: Enter a desired file name, and select Save.
    9) PC side: When upload is completed, the complete message is dis-
    played.
    With the above procedure, the EEPROM data acquisition is completed.
    Data acquired by the EEPROM data acquisition procedure are saved
    in a file with extension of .eep.
    5. Installing procedures
    
    Driver installation is made on plug-and-play.
    
    1) Main unit side: Execute Test command No. 49-01 (Flash ROM pro-
    gram write mode).
    Check that DOWNLOAD MODE is displayed on the LCD of the
    operation panel. (Press and hold [CA] key and [DOWN] key (left
    key) together, and turn on the power simultaneously.)
    2) Connect the machine and the PC with a USB cable.
    3) The following display is shown.
    Select [Install from a list or specific location] and press  but-
    ton.
    4) Select [Include this location in the search;]. If the search location is
    not the folder which includes the maintenance tool driver
    (Mainte.inf), select . If the search location is the folder
    which includes the maintenance tool driver, press  button to
    go to procedure 7).
    e-STUDIO162_151.book  5 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 6 5) Select the folder which includes the maintenance tool driver
    (Mainte.inf) and press  button.
    (Suppose that the driver is included in C:\MaintenanceTool\Drivers\
    2kXp folder.)
    6) Check the path to the folder which includes the maintenance tool
    driver (Mainte.inf), and press  button.
    7) When the following display is shown, press [Continue Anyway] but-
    ton.8) When the following display is shown, installation is completed.
    Press  button.
    With the above procedures, installation (on Windows XP) of the inte-
    gration maintenance program is completed.
    
    1) Main unit side: Execute Test command No. 49-01 (Flash ROM pro-
    gram write mode).
    Check that DOWNLOAD MODE is displayed on the LCD of the
    operation panel. (Press and hold [CA] key and [DOWN] key (left
    key) together, and turn on the power simultaneously.)
    2) Connect the machine and the PC with a USB cable.
    3) Check that the Found New Hardware Wizard is displayed, and
    press  button.
    4) Select [Search for a suitable driver for my device] and press 
    button.
    e-STUDIO162_151.book  6 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 7 5) Select [Specify a location] and press  button.
    6) Select [Include this location in the search;]. If the search location is
    not the folder which includes the maintenance tool driver
    (Mainte.inf), select . If the search location is the folder
    which includes the maintenance tool driver, press  button to
    go to procedure 9).
    7) Specify the folder which includes the maintenance tool driver
    (Mainte.inf), and press  button.8) Check that the path to the folder which includes the maintenance
    tool driver (Mainte.inf) is displayed, and press  button.
    (Suppose that the maintenance tool driver is included in 
    C:\MaintenanceTool\Drivers\2kXp folder.)
    9) Press  button to start installation.
    10) When the following display is shown, installation is completed.
    Press  button.
    11) Restart the PC.
    With the above procedures, installation (on Windows 2000) of the inte-
    gration maintenance program is completed.
    e-STUDIO162_151.book  7 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							e-STUDIO162/162D/151/151D FIRMWARE DOWNLOAD PROCEDURES  15 - 8 
    1) Main unit side: Execute Test command No. 49-01 (Flash ROM pro-
    gram write mode).
    Check that DOWNLOAD MODE is displayed on the LCD of the
    operation panel. (Press and hold [CA] key and [DOWN] key (left
    key) together, and turn on the power simultaneously.)
    2) Connect the machine and the PC with a USB cable.
    3) The following display is shown on the PC side.
    Select [Specify the location of the driver], and press  button.
    4) Select [Specify a location], specify the folder which includes the
    maintenance tool driver (Mainte.inf) as the search location, and
    press  button.
    If the search location does not include the maintenance tool driver
    (Mainte.inf), press  button to specify the folder which
    includes the maintenance tool driver (Mainte.inf).
    (Suppose that the maintenance tool driver is included in 
    C:\MaintenanceTool\Drivers\Win9xMe folder.)
    5) Select the folder which includes maintenance tool driver
    (Mainte.inf), and press  button.
    (Suppose that the driver is included in 
    C:\MaintenanceTool\Drivers\Win9xMe folder.)6) Check that the path to the folder which includes the maintenance
    tool driver (Mainte.inf) is displayed, and press  button.
    7) When the following display is shown, installation is completed.
    Press  button.
    8) Restart the PC.
    With the above procedures, installation (on Windows ME) of the inte-
    gration maintenance program is completed.
    e-STUDIO162_151.book  8 ページ  2004年12月2日 木曜日 午後9時48分 
    						
    							Memo
    memo.fm  1 ページ  2004年12月3日 金曜日 午前9時50分 
    						
    All Toshiba manuals Comments (0)