e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 22 46 29 Image contrast adjustment (600dpi) (GAMMA 600)[Function] Contrast is set for each mode. When this test command is executed, the current se value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to make a copy under the set value. When the set value is increased, the contrast becomes higher. When the set value is decreased, the contrast becomes lower. In this case, only Exp.3 copy is made. When, however, the setting is made to make higher contrast, Exp.1 and Exp.5 copies also become in higher contrast. When made to a lower contrast, Exp1. and Exp.5 copies become lower contrast, too. Press [ ←/→] key to switch the mode. The set value of the selected mode is displayed on the LCD. (Adjustment value: 1 – 99) ∗No density display on LCD. [Operation] The operation is similar to test command 46-01. 30 AE limit adjustment (AE LIMIT)[Function] Used to set the limit value in AE and AE (toner save). Change the setting and press [OK (ENTER)/START] key to write the setting into the EEPROM. The machine goes into the sub code entry standby mode. By pressing [ ←/→] key, setting is changed. (Setting range: 0 – 31, Default: 0) When test command 26-06 (Destination setting) or test command 46-19 Auto Exposure mode is changed, the setting of this test command is also changed to the default in connection. [Operation] The operation is similar to test command 46-19. 31 Image sharpness adjustment (SHARPNESS)[Function] Used to adjust sharpening/blurring of image in each mode. When this test command is executed, warm-up and shading are performed and the current set value is displayed. (Default: 1) Change the set value and press [START] key to make a copy under the set conditions. To change the mode, press [ ←/→] key. The code number of the selected mode is dip0slayed on the LCD. [Operation] The operation is similar to test command 46-01. Main codeSub codeContents Details of function/operation Mode Display item Default LED AE mode (600dpi) AE 50 COPY mode lamp TEXT mode (600dpi) TEXT 50 PRINT mode lamp PHOTO mode PHOTO 50 SCAN mode lamp TS mode (TEXT)(600dpi) TSTXT 50 PRINT mode lamp SCAN mode lamp TS mode (AE)(600dpi) TSAE 50 COPY mode lamp SCAN mode lamp Mode Display item Remark Limit value for AE AE Limit value for AE (toner save) TSAE Image quality Setting No Remark Blurring 0 Standard 1 Default Sharpening 2 Mode Display item Default setting LED AE mode AE 1 COPY mode lamp TEXT mode TEXT 1 PRINT mode lamp PHOTO mode PHOTO 1 SCAN mode lamp TS mode (TEXT) TSTXT 1 PRINT mode lamp SCAN mode lamp TS mode (AE) TSAE 1 COPY mode lamp SCAN mode lamp e-STUDIO162_151.book 22 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 23 46 32 Copier color reproduction setting (COLOR REAPPEAR)[Function] Used to set color reproduction in each mode. Colors easy to be copied and colors difficult to be copied can be switched. ∗This setting has virtually no effect on black-and-white documents. When this test command is executed, warm-up and shading are performed and the current set value is displayed. (Default: 0) Press [START] key to make a copy under the set conditions . At that time, color components are changed for used in copying. To change the mode, press [ ←/→] key. The code number of the selected mode is dip0slayed on the LCD. [Operation] The operation is similar to test command 46-01. 39 FAX mode sharpness adjustment (Executable only when the FAX is installed.)[Function] When [START] key is pressed, scan is started with the entered sharpness adjustment value, and the data of the selected mode stored on the FAX side is changed to the entered value. [Operation] Main codeSub codeContents Details of function/operation Set value Colors easy to be copied Colors difficult to be copied 0 Purple, Blue, Red Yellow, Green, Water blue 1 Water blue, Green, Blue Purple, Red, Yellow 2 Yellow, Red, Green Blue, Water blue, Purple Specification component Setting No Remark Green 0 Default Red 1 Blue 2 Mode Display item Default setting LED AE mode (including TS) AE 0 COPY mode lamp TEXT mode (including TS) TEXT 0 PRINT mode lamp PHOTO mode PHOTO 0 SCAN mode lamp Sharpness adjustment value data table When initializing each data: 1Mode Sharpness adjustment value 1: STD 2: FINE 3: S-FINE 4: FINE/PHOTO 5: S-FINE/PHOTO 1) Initial display 2) [ ←/→] or after 2sec Every time when [ →] key is pressed, the second line is changed in the sequence of No. 1 → 2 → 3 → 4 → 5 → 1. When [ ←] key is pressed, the sequence is reversed. 3) Select the arrow key 1-5, and the LED of [START] key is lighted. (ZZZZ is the mode selected among STD, FINE, S-FINE, FINE/PHOTO, and S-FINE/ PHOTO.) (X is the corresponding sharpness adjustment value of the selected mode stored on the FAX side.) ∗[CLEAR] key: Returns to “2)” display.4) Enter a one-digit value (0-2) as the sharp- ness adjustment value with [10KEY]. (Y is the entered sharpness adjustment value.) ∗[CLEAR] key: Returns to “2)” display. 5) Scan start (self print) 6) Print start (self print) After completion of printing, returns to “4)” display. SHARPNESS SETTING PRESS ←,→ SHARPNESS SET (1-5) 1:STD SHARPNESS SETTING ZZZZ(0-2) X SHARPNESS SETTING ZZZZ(0-2) Y SHARPNESS SETTING SCAN Y SHARPNESS SETTING PRINT Y e-STUDIO162_151.book 23 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 24 48 01 Main scan/sub scan direction magnification ratio (COPY MAG.)[Function] Used to adjust the magnification ratio in the main scan (front/rear) direction and sub scan direction. Enter the adjustment value with [10KEY]. Press [START] key to save the set value and make a copy. (When the adjustment value is increased by 1, the magnification ratio is increased by 0.1%.) The adjustment mode can be changed by pressing [ ←/→] key. (Adjustment range: 1 – 99, Default: 50) [Operation] The operation is similar to test command 46-01. 05 ADF/RADF mode sub scan direction magnification ratio in copying (ADF/RADF MAG.) (Disabled when set to OC) (Executable only when the ADF/RADF is installed.)[Function] Used to display the current ADF/RADF mode sub scan direction magnification ratio on the LCD. When [START] key is pressed, the entered data is acquired and saved into the EEPROM, and a copy is made. (When the set value is increased by 1, the magnification ratio is increased by 0.1%.) (Adjustment range: 1 – 99, Default: 50) When adjusting the RADF, use [2-SIDED COPY] key to select single/duplex after entering the one page print mode, performing 2-page single copy. For printing, regardless of the density mode and the density level, Density mode = MANUAL Density level = 3 ∗When there is no document in ADF, copy is inhibited. *1: Only when RADF is installed. If installed, skipped. [Operation] The operation is similar to test command 46-01. Main codeSub codeContents Details of function/operation Mode Display item Default value LED Main scan direction magnification ratio F-R 50 PRINT mode lamp OC mode sub scan direction magnification ratioSCAN 50 SCAN mode lamp Mode Display item Default LED Sub scan magnification ratio adjustment on the surface of ADF/RADF document SIDE1 50 COPY mode lamp Sub scan magnification ratio adjustment on the surface of RADF document *1SIDE2 50 PRINT mode lamp e-STUDIO162_151.book 24 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 25 49 01 Download mode (DOWNLOAD MODE)[Function] When this test command is executed, DLOWNLOAD MODE is displayed on the LCD and the machine goes into the program writing mode from PC to Flash ROM. Use the writing tool on the PC and write the program. During writing, the display shows as follows: After completion of download, turn OFF/ON the power to reset. In case of an error in download, the following message is displayed on the LCD. To enter the download mode, there is a method to use key operations as well as to use a test com- mand. With the power OFF, press and hold [CA] + [ ←], turn on the power. [Operation] Main codeSub codeContents Details of function/operation Status Display item Download data receiving RECEIVING Loader function transfer LOADER COPYING Date delete start FLASH ERASE Data write (Boot section) BOOT WRITING Data write (Program section) PROGRAM WRITING Data write (EEPROM) E2PROM WRITING Data write (LCD) LCD DATE WRITING During SUM CHECK FLASH ROM SUM CHECK During BOOT SUM CHECK BOOT SUM CHECK During EEPROM SUM CHECK EEPROM SUM CHECK Download complete DOWNLOAD COMPLETE! Error status Display item PC data receiving E-01 PC TRANS Loader function transfer E-02 LOADER COPY FLASH ROM delete E-03 FLASH ERASE Boot section FLASH ROM write E-04 BOOT WRITE Program section FLASH ROM write E-05 PROGRAM WRITE Loader section SUM CHECK E-06 LOADER SUM Boot section SUM CHECK E-07 BOOT SUM Program section SUM CHECK E-08 PROGRAM SUM E2PROM SUM CHECK E-09 E2PROM SUM E2PROM write E-10 E2PROM WRITE E2PROM read Verify E-11 E2PROM READ E2PROM collating Verify E-12 E2PROM COLLATE Boot section lens check E-13 BOOT LENGTH Program section lens check E-14 PROGRAM LENGTH E2PROM lens check E-15 E2PROM LENGTH Total data size check E-16 DATE SIZE IMC communication error E-17 IMC TRANS IMC FRASH ROM write E-18 IMC FLASH WRITE LCD section lens check E-19 LCD DATE LENGTH LCD section FLASH ROM write E-20 LCD DATE WRITE LCD section SUM CHECK E-21 LCD DATE SUM 1) Initial display DOWNLOAD MODE e-STUDIO162_151.book 25 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 26 50 01 Lead edge image position (LEAD EDGE)[Function] Used to adjust the copy image position and the lead edge void amount on copy paper. The adjust- ment is made by adjusting the image scan start position at 100% and the print start position (resist roller ON timing). When this test command is executed, the current set value is displayed in 2 digits. (Center value: 50) When [ ←/→] key is pressed, the setting mode and the display are changed. Enter the adjustment value and press [START] key to save the set value and make a copy. When the adjustment is made by the main cassette paper feed, the adjustment values of all the paper feed ports become the same. (When the set value is increased by 1, shift is made by 0.1mm.) (*): Support for the installation models. For non-installation models, skip. [Adjustment procedure] 1) Set the print start position (A: COPY mode lamp ON), the lead edge void amount (B: PRINT mode lamp ON), the scan start position (C: SCAN mode lamp) to zero, and make a copy of the scale at 100%. 2) Measure the image loss (Rmm) of the scale. Set C = 10 x R (mm). (Example: Set to 40.) When the value of C is increased by 10, the image loss is decreased by 1mm. (Default: 50) 3) Measure the distance (Hmm) from the paper lead edge to the image print start position. Set A = 10 x H (mm). (Example: Set to 50.) When the value of A is increased by 10, the image lead edge is moved to the paper lead edge by 1mm. (Default: 50). 4) Set the lead edge void amount to B = 50 (2.5mm). (Default: 50) When the value of B is increased by 10, the void is extended by about 0.1mm. (For 25 or less, however, the void amount is regarded as 0.) ∗The SFP adjustment is made by adjusting the ADF image scan start position after OC adjustment. ∗When paper is discharged, the shifter is operated. (Example) [Operation] The operation is similar to test command 46-01. Main codeSub codeContents Details of function/operation Mode Display item Default LED Print start position (Main cassette paper feed)TRAY1 50 COPY mode lamp Main cassette lamp (*) Print start position (2nd cassette paper feed)TRAY2 50 COPY mode lamp 2nd cassette lamp Print start position (Manual paper feed)MFT 50 COPY mode lamp Manual feed lamp Image lead edge void amount DEN-A 50 PRINT mode lamp Image scan start position RRC-A 50 SCAN mode lamp Image rear edge void amount DEN-B 50 COPY mode lamp PRINT mode lamp SCAN mode lamp 5mm 10mm Distance from the paper lead edge to the image lead edge, H = 5mm Image loss, R = 4mm e-STUDIO162_151.book 26 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 27 50 06 Copy lead edge position adjustment (ADF/RADF) (ADF/RADF EDGE) (Disabled when set to OC) (Executable only when the ADF/RADF is installed.)[Function] Used to adjust the ADF copy lead edge. When the adjustment value of the document scan position adjustment is increased by 1, the scan start timing is advanced by 0.1mm. The print result is shifted to the opposite direction of the scan start position. The adjustment mode can be changed by pressing [ ←/→] key. (Adjustment range: 1 – 99, Default:50) When scanning a back surface of document, the mode must be changed to operate the RADF by pressing [2-SIDED COPY] key. (*) : Support for the installation models. For non-installation models, skip. ∗When there is no document in the ADF, copy is inhibited. ∗When paper is discharged, the shifter is operated. [Operation] The operation is similar to test command 46-01. 10 Print center offset adjustment (PRT.OFF- CENTER)[Function] Used to adjust the center offset position of copy images on copy paper and that in scanning docu- ment. When this test command is executed, the current set value is displayed. Enter the adjustment value and press [START] key to save the setting and make a copy. (When the set value is changed by 1, the center is shifted by 0.1mm.) When the adjustment value is increased, the center is shifted to right. When decreased, the center is shifted to left. The modes can be selected by pressing [ ←/→] key. When the set value is changed largely, the area outside the shading area may be scanned to cause black streaks on the edges. When the RADF is used, select the mode for use of the RADF by [2- SIDED COPY] key. (*) : Support for the installation models. For non-installation models, skip. ∗In the 2nd print center offset adjustment, print is made forcibly as 1to2/Short Edge from OC regard- less of duplex setting. ∗When paper is discharged, the shifter is operated. [Operation] The operation is similar to test command 46-01. 12 Document feed off-center adjustment (ORG.OFF- CENTER)[Function] Used to adjust document scan off-center adjustment. The adjustment modes can be selected by pressing [ ←/→] key. (Adjustment range: 1 – 99, Default:50) When the adjustment value is increased, the print result is shifted to left. (*) : Support for the installation models. For non-installation models, skip. ∗When paper is discharged, the shifter is operated. [Operation] The operation is similar to test command 46-01. Main codeSub codeContents Details of function/operation Mode Display item Default LED Front surface document scan position adjustmentSIDE1 50 COPY mode lamp (*) Back surface document scan position adjustmentSIDE2 50 PRINT mode lamp Rear edge void adjustment (ADF) END 50 SCAN mode lamp Mode Display item Default LED Print center offset (Main cassette paper feed)TRAY1 50 COPY mode lamp Main cassette lamp (*) Print center offset (2nd cassette paper feed)TRAY2 50 COPY mode lamp 2nd cassette lamp Print center offset (Manual paper feed) MFT 50 COPY mode lamp Manual feed lamp (*) 2nd print center offset (Main cassette paper feed) SIDE2 50 PRINT mode lamp Main cassette lamp Mode Display item Default LED Platen document scan OC 50 COPY mode lamp (*) ADF document front scan ADF 50 PRINT mode lamp (*) RADF document back scan RADF 50 SCAN mode lamp e-STUDIO162_151.book 27 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 28 50 18 Memory reverse position adjustment in duplex copy (DPLX REVERSE) (Enabled when Duplex setting is ON with OC or ADF set) (Executable only when the RADF is installed.)[Function] When this test command is executed, the current set correction value is displayed. Enter the correction value and press [START] key to save the entered correction value. (Correction value range; 1 – 99, Default: 50) For S-D mode front surface print and print of even paged in D-S mode, reverse memory copy opera- tion is performed from the rear edge of documents. When, therefore, the print position adjustment of output images is required, adjust as follows: In the reverse memory coping, when the document scan is made in the arrow direction, the output image is printed from the rear edge of scan image, When, therefore, the print lead edge is shifted, set the reference chart so that the reference position is on the rear edge, and use this test command to adjust the set value so that the print lead edge is matched. Since printing is made from the image data most lately stored in memory to the lead edge data from the print start position, the image lead edge adjustment is made by changing the end data position stored in memory by the set value of this test command. Since it is performed by changing the scan end position, the image position adjustment is made by changing the scan end position and the end data stored in memory. ∗The initial value of duplex setting is 1to2/Long Edge for the duplex model, or 2to1 for the simplex model. ∗When paper is discharged, the shifter is operated. [Operation] The operation is similar to test command 46-01. 19 Duplex copy rear edge void adjustment (DPLX END EDGE) (Enabled when Duplex setting is ON) (Executable only when the RADF is installed.)[Function] Used to adjust the rear edge void amount in duplex copy. When this test command is executed, the current set value is displayed in 2 digits. (Center value: 50.) The adjustment modes can be selected by pressing [ ←/→] key. (Adjustment range; 1 – 99) Enter the adjustment value and press [START] key to save the set value and make a copy. (The paper information is cleared for every copy.) When the set value is increased by 1, the void amount is increased by about 0.1mm. ∗The initial value for duplex setting is 1to2/Short Edge for the OC/ADF setting, or 2to2 for the RADF setting. ∗When paper is discharged, the shifter is operated. [Operation] The operation is similar to test command 46-01. Main codeSub codeContents Details of function/operation *1: Only when ADF/RADF is installed. If installed, skipped.Mode Display item Default LED OC memory reverse output position OC 50 COPY mode lamp ADF memory reverse output position *1 ADF 50 PRINT mode lamp Document transport directionDocument transport direction Scan lead edge Print lead edge Lead edge void (1) Print start position Scan end position (Default: Scan cut by void (1)) Rear edge void Print rear edge Scan direction Scan rear edge Mode Display item Default LED Paper rear edge void amount DEN-B 50 PRINT mode lamp Print start position (Duplex back surface) RRC-D 50 SCAN mode lamp e-STUDIO162_151.book 28 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 29 51 02 Resist amount adjustment (RESIST ADJ.)[Function] Used to adjust the contact pressure of the main unit resist roller and the RADF resist roller onto paper. When this test command is executed, the current set value is displayed. The adjustment modes can be selected by pressing [ ←/→] key. Enter the adjustment value with [10KEY] and press [START] key to save the set value and make a copy. (*): Support for the installation models. For non-installation models, skip. [Operation] The operation is similar to test command 46-01. 53 08 ADF scan position automatic adjustment (ADF AUTO) (Disabled when set to OC) (Executable only when the ADF is installed.)[Function] Place a black chart so that it covers the ADF scan glass and the OC glass together, and close the OC cover. When this test command is executed, the current adjustment value is displayed as the initial display. ∗Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.127mm ∗If the values are kept as the default values, ADF scan is not performed properly. The front area of the proper scan position may be scanned. In case of AUTO, press [START] key, and the mirror unit scans from the home position to the ADF scan position with the adjustment value displayed. The ADF glass cover edge position is calculated from the difference between the SPFG glass cover edge and the OC side document glass CCD out- put level. If the adjustment is normal, the adjusted value is displayed. If abnormal, the error LED lights up with the current set value displayed. During the error LED is lighted, when [START] key is pressed again, execution is performed again. [Operation] The operation is similar to test command 46-01. (In MANUAL) OK/ERR display in AUTO 61 03 HSYNC output check (LSU CHK)[Function] When [OK (ENTER)/START] key is pressed, HSYNC is performed and the polygon motor is rotated for 30sec. At that time, the COPY mode lamp is lighted for 100msec every time when HSYNC is detected. [Operation] Main codeSub codeContents Details of function/operation Mode Display item Default LED Main cassette paper fed TRAY1 50 COPY mode lamp Main cassette lamp (*) 2nd cassette paper feed TRAY2 50 COPY mode lamp 2nd cassette lamp Manual paper feed MFT 50 COPY mode lamp Manual feed lamp (*) RADF document paper feed (Front surface)SIDE1 50 COPY mode lamp PRINT mode lamp SCAN mode lamp (*) RADF document paper feed (Back surface) SIDE2 50 COPY mode lamp PRINT mode lamp (*) Duplex back surface DUP-2 50 PRINT mode lamp SCAN mode lamp Mode Display item Default LED ADF scan position auto adjustment AUTO 1 COPY mode lamp ADF scan position manual adjustment MANU 1 PRINT mode lamp 53-08 ADF AUTO AUTO 100% ** OK53-08 ADF AUTO AUTO 100% ** ERR 1) Initial display 61-03 LSU CHK EXECUTING... e-STUDIO162_151.book 29 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 30 63 01 Shading check (SHADING CHK)[Function] Used to display the detection level of white plate for shading. When [OK (ENTER)/START] key is pressed, the mirror base unit moves to the white plate for shading and the copy lamp is lighted. When the light quantity is stabilized, revision is made for every second, and the level of one pixel at the center of CCD which is not corrected is detected and the value is displayed in decimal values on the LCD. (3 digits) [Operation] 02 Black level automatic correction (BLACK LEVEL)[Function] Used to acquire the black level target value used for the black level adjustment of white balance. When this test command is executed, the current correction value is displayed in 3 digits of 12bit hexadecimal number. Place the gray gradation chart used as the correction document so that the density 10 (black side) comes on the left side and that the chart is upside down at the center of the plate left center. When [OK (ENTER)/START] key is pressed, the mirror base unit scans the chart and calculates the correction value. After completion of correction, the corrected value is displayed on the LCD. ∗Default: 0 ∗If the value is set to the default, operation is made with 0x60. [Operation] Main codeSub codeContents Details of function/operation 1) Initial display 63-01 SHADING CHK EXECUTING... 000 Chart back surface 10 1) Initial display 2) [OK (ENTER)/START] Correction start 63-02 BLACK LEVEL 000 63-02 BLACK LEVEL EXECUTING... After canceling, the machine goes into the sub code entry standby mode. 3) After execution 3) In case of an errorTHE JOB IS BEING CANCELED. 63-02 BLACK LEVEL *** OK 63-02 BLACK LEVEL *** ERR 10_TESTCOMMAND.fm 30 ページ 2004年12月22日 水曜日 午後3時40分
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 31 64 01 Self print (1by2 mode) (SELF PRT.)[Function] The status of the optical section is ignored and printing of one page is made. Also when the print com- mand is received from the host, printing is made. When this test command is executed, warm-up is performed and the ready lamp is lighted. (Since, however, the scanner is disabled, initializing is not made.) Enter the code number and press [OK (ENTER)/START] key to start paper feed from the selected cassette and print in the selected pattern. ∗For 4 – 99, flip. [Operation] The operation is similar to test command 21-01. 66 01 FAX soft SW setting (Executable only when the FAX is installed.)[Function] Use to check the FAX soft SW setting. Every time when the key is pressed, the bit on the first line is switched 0 and 1. [Operation] 02 FAX soft SW initializing (excluding the adjustment values) (Executable only when the FAX is installed.)[Function] Use to initializing FAX soft SW. [Operation] Main codeSub codeContents Details of function/operation Code number Pattern Display item 0 1by2 1 BY 2 1 Grid pattern CHECK 2 White paper WHITE 3 Black background BLACK 1) Initial display ∗[CLEAR] key: FAX control is terminated. 2) Enter a 3-digit value of soft SW No. (To enter the fourth digit, shift to the left.), and the press [OK (ENTER)] key. xxxxxxxx is the set content. ∗Select 2: Returns to the soft SW No. entry dis- play.3) Select 1 4) Change with 1-8 of [10KEY] and the press [OK (ENTER)] key. xxxxxxxx is the set content. ∗Select 2: Returns to the soft SW No. entry dis- play. 5) Select 1 After 2sec, returns to 1) Initial display. ENTER FAX SOFT SW. # (3 DIGITS) SW.___ No.### xxxxxxxx CHANGE? 1:YES 2:NONo.### xxxxxxxx USE # KEY 12345678 No.### xxxxxxxx STORED? 1:YES 2:NO STORED 1) Initial display After 2sec, FAX control is terminated. INITIALIZED e-STUDIO162_151.book 31 ページ 2004年12月2日 木曜日 午後9時37分