e-STUDIO162/162D/151/151D SPECIFICATIONS 2 - 3 4. SPLC printer *1: Engine Resolution *2: Running change 5. Scan function *1: Running change ∗ADF/RADF: Optional Duplex: e-STUDIO162D/151D Print speed Max. 15ppm (A4 / with ROPM) / 16ppm (Letter / with ROPM) First print time 9.6 sec. (without data transfer time) Duplex Yes (e-STUDIO162D/151D) ROPM Yes CPU None Memory Share the memory with E-SORT function Interface IEEE1284 / USB 2.0 Network External NIC (Optional) Emulation SPLC (JBIG GDI) MIB support Yes (with GA-1170) Resolution 600dpi *1 Supported OS Win 95 / 98 / Me / NT 4.0 / 2000 / XP WHQL support Yes *2 Application Status window Type Flat Bed Color Scanner Scanning system Document glass / ADF / RADF ∗ Light source 3 CCDs (RGB) sensor scanning by lighting white lamp (2 pcs of CCFL) Resolution Optical: 600 x 1200dpi Setting range: 50 - 9600dpi (Preview resolution is fixed at 75dpi) Originals Sheet type / Book type Output data R, G, B 1 or 8 bits/pixel / A/D 16bit Scan range OC / RADF ∗: 8.5 (215.9mm) (L) x 14 (355.6mm) (W) Original position: Platen: Left center / ADF ∗: Right center Scan speed OC / ADF ∗: Max. 2.88ms/line (Color/Gray scale), Max. 0.96 ms/line (B & W) Protocol TWAIN / WIA (Only XP) / STI Support file format RAW Interface USB2.0 Scanner utility Button Manager / Desktop Document Manager Scan key/lamp Yes Duplex scan Yes (with RADF, TWAIN) Supported OS Win 98 / Me / 2000 / XP Void area No (User settable by PC) WHQL supported Yes *1 02_SPECI.fm 3 ページ 2004年12月22日 水曜日 午後1時10分
e-STUDIO162/162D/151/151D CONSUMABLE PARTS 3 - 1 [3] CONSUMABLE PARTS 1. Supply list A. Europe/SCA/SCNZ Note: Printing of the master/individual cartons is made in 2 languages, English/French. Packed together with the machine: DR 25K/Process UN 2. Environmental The environmental conditions for assuring the copy quality and the machine operations are as follows: (1) Normal operating condition Temperature: 20 °C to 25 Humidity: 65 ± 5%RH (2) Acceptable operating condition (3) Transportation condition(4) Supply storage condition 3. Production control number (lot No.) identification ∗: Destination code No. Item Content Life Product name Package Remark 1 Toner CA (Black) Toner (Toner: Net Weight 243g) × 10 8K× 10PLSPS-ZT1200 1∗Life setup is based on A4 6%. Polyethylene bag × 10 2 Developer Developer (Developer: Net Weight 170g) × 1 25K D-1200 1 3 Drum kit Drum × 1 25K OD-1200 10 Drum fixing plate × 1 Humidity (RH) 85% 60% 20% 10˚C 30˚C 35˚C Humidity (RH) 90% 60% 15% –25˚C30˚C40˚C Classification No. EX DestinationA packed with machine G B packed with machine H Option DestinationAP BQ Humidity (RH) 90% 20% –5˚C45˚C Production month Production day Destination code ∗ (Dealer, distributor, OEM, etc.) Production place End digit of year Version No. 03_CONSU.fm 1 ページ 2004年12月22日 水曜日 午後1時36分
e-STUDIO162/162D/151/151D CONSUMABLE PARTS 3 - 2 The label on the drum cartridge shows the date of production. (JAPAN production) ∗1 The production control label is not attached to the cartridge of a China product. 4. Toner cartridge replacement 1) Open the front and side cabinets of the copier. 2) Keep holding Toner lever, and 3) Carefully pull out Toner unit from the copier. 4) Put Toner unit in a collection bag immediately after removing it from the copier Note: Never carry exposed Toner unit. Be sure to put it in the collection bag. Division No. Option 2 Packed with machine 3 Production month Production day Destination code (Dealer, distributor, OEM, etc.) Production place End digit of year Version No. X 0001 1 9 Ver.A1 Production month (1 - 9 = Jan. - Sep. 0 = Oct. X = Nov. Y = Dec.) Serial number of month Fixed to 1. Pack division (See table below) End digit of year Version No. Production control label attachment position Production control label attachment position(*1) Sub lot Production day Production month End digit of year Production place 1 3 2 03_CONSU.fm 2 ページ 2004年12月22日 水曜日 午後3時38分
e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 1 [4] EXTERNAL VIEWS AND INTERNAL STRUCTURES 1. Appearance (With optional ADF/RADF installed) 2. Internal (With optional ADF/RADF installed)1 Document glass 2 Operation panel 3 Front cover 4 Paper tray 5 Side cover 6 Side cover open button 7 Bypass tray paper guides 8 Bypass tray 9 Reversing tray (RADF only) 10 Original guides 11 Document feeder cover 12 Document feeder tray 13 Exit area 14 Document cover 15 Paper output tray 16 Paper output tray extension 17 Power switch 18 Handles 19 Power cord 20 USB connector 21 Parallel connector 22 Paper holder arm 1 Front cover 2 Side cover 3 Fusing unit release lever 4 Transfer charger 5 Charger cleaner 6 Photoconductive drum 9 10 11 12 13 2 3 4 1 5 7 6 814 ADF/RADF (Option) 16 15 19 22 Interface 18 18 17 20 21 3 4 5 2 1 Toner cartridge 6 e-STUDIO162_151.book 1 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 2 3. Operation panel (e-STUDIO151/151D (Europe)) (e-STUDIO162/162D) 1[MODE SELECT] key / Mode indicators Press this key to select the mode. The indicator of the selected mode lights (copy, printer, scanner, fax mode indicators).2Display This shows messages indicating the machine status and any problems that occur, as well as user programs and function setting menus. 3Numeric keys Use these to enter the number of copies and other numerical settings. The keys can also be used to select items in function setting menus.4[CLEAR] key ( ) Use this to clear the set number of copies, as well as cancel a job that is in progress. When a setting menu appears, use this key to move back to the previous menu level. 5Power save indicator This lights up when the power save function is activated.6ADF/RADF indicator (Option) This lights up when an original is placed in the ADF/RADF. 7Error indicator This lights steadily or blinks when a paper misfeed or other error occurs.8[TRAY SELECT] key ( ) Use to select the paper tray that has the desired paper for copying. 9Tray location indicator Indicates the selected paper tray. The indicator blinks when the tray is out of paper or is not closed.10[MENU] key Press this key to select the paper size for copying, to configure a user program or to display the total count. 11[2-SIDED COPY ] key (e-STUDIO162D/151D) Press to select the automatic two-sided copying mode.12[E-SORT/SP.FUN ] key Press to select the sort function, 2 IN 1 copy function, or margin shift function. 13[ ] key ( ), [ ] key ( ), [OK (ENTER)] key Press the [ ] key ( ) or [ ] key ( ) to select an item in a function setting menu. Press the [OK (ENTER)] key to enter a selection.14[EXPOSURE ] key Use to switch from auto exposure adjustment to text mode or photo mode. 15[ZOOM (COPY RATIO)] key Press to select an enlargement or reduction ratio. To select a preset ratio setting, press the [ZOOM (COPY RATIO)] key and select the desired preset ratio. To select a ratio that is not preset, press the [ZOOM (COPY RATIO)] key, select the preset ratio that is closest to the desired ratio, and then press the [ ] key ( ) or [ ] key ( ) to increase or decrease the ratio in increments of 1%.16[START] key ( ) / Ready indicator The ready indicator lights up when copying or scanning is possible. To begin copying, press the [START] key ( ). The [START] key ( ) is also pressed to return to normal operation from auto power shut-off mode. 17[CLEAR ALL] key ( ) This returns all functions to the default settings. When pressed in a setting menu, this returns the settings and display to the initial state.18 Shows the current copy ratio. 19 Shows the selected paper size. 20 Shows the number of copies that has been entered with the numeric keys. 21 A checkmark appears when the exposure has been changed, or when two-sided copying, sort, 2 IN 1, or margin shift is selected. 6 7 8 9 10 11 12 13 14 15 12 1,2,3, 1,2,3,SP. FUNCZOOM MENUOKREADY TO COPY. 100% A4 0 Display 16 1718 19 20 21 345 READY TO COPY. 100% 8.5x11 0 Display 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 12345 04_EXTER.fm 2 ページ 2004年12月22日 水曜日 午後1時41分
e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 3 4. Motors and solenoids (With optional ADF/RADF installed) No. Part name Control signal Function / Operation 1 Main motor MM Drives the copier. 2 Scanner motor MRMT Drives the optical mirror base (scanner unit). 3 Toner motor TM Supplies toner. 4 Cooling fan motor VFM Ventilate the fuser section. 5 Resist roller solenoid RRS Resist roller rotation control solenoid 6 Paper feed solenoid CPFS1 Cassette Paper feed solenoid 1 7 Multi paper feed solenoid MPFS Multi manual pages feed solenoid 8 ADF motor SPFM Drives the single pass feeder 9 Duplex motor DMT Devices the duplex paper transport section (Duplex model only) 10 Original feed solenoid SPUS Original pick up solenoid 11 ADF paper feed solenoid SPFS Original feed solenoid (RADF only) 12 ADF gate solenoid SGS Controls the document reverse gate. (RADF only) 13 Shifter motor SFTM Drives the shifter. 1 4 8 11 2 12 139 10 5 76 3 e-STUDIO162_151.book 3 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 4 5. Sensors and switches (With optional ADF/RADF installed) No. Name Signal Type Function Output 1 Scanner unit home position sensorMHPS Photointerrupter Scanner unit home position detection H at home position 2 POD sensor POD Photointerrupter Paper exit detection H at paper pass 3 PPD2 sensor PPD2 Photointerrupter Paper transport detection 2 L at paper pass 4 Cassette detection switch CED1 Micro-switch Cassette installation detection H at cassette insertion 5 PPD1 sensor PPD1 Photointerrupter Paper transport detection 1 L at paper pass 6 Door switch DSW Micro-switch Door open/close detection (safety switch for 24V)1 or 0V of 24V at door open 7 ADF sensor SPID/ SD SWPhotointerrupter Paper entry detection Cover open/close detectionL at paper pass 8 SPPD sensor SPPD Photointerrupter Paper transport detection L at paper pass 9 PD1 sensor PD1 Micro-switch Paper width detect H at A4 size or less L at A4 size or more 1 8 7 2 3 4 5 9 6 04_EXTER.fm 4 ページ 2004年12月22日 水曜日 午後1時41分
e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 5 6. PWB unit (With optional ADF/RADF and FAX installed) No. Name Function 1 Exposure lamp inverter PWB Exposure lamp (CCFL) control 2 Main PWB (MCU) Copier control 3 Operation PWB Operation input/display 4 Power PWB AC power input, DC voltage control, High voltage control 5 CCD sensor PWB For image scanning 6 LSU motor PWB For polygon motor drive (In the LSU) 7 TCS PWB For toner sensor control 8 LSU PWB For laser control (In the LSU) 9 FAX-operation PWB FAX operation input (GD-1190 option) 10 Modem PWB FAX control (GD-1190 option) 15 2 8 6 7 3 4 9 10 e-STUDIO162_151.book 5 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 6 7. Cross sectional view (With optional RADF installed) No. Part name Function and operation 1 Scanner unit Illuminates the original with the copy lamp and passes the reflected light to the lens unit(CCD). 2 Exposure lamp Exposure lamp (CCFL) Illuminates original 3 LSU (Laser unit) Converts the original image signal into laser beams and writes onto the drum. 4 Paper exit roller Roller for paper exit 5 Main charger Provides negative charges evenly to the drum surface. 6 Heat roller Fuses toner on the paper. (Teflon roller) 7 Pressure roller Fuses toner on the paper. (Silicon rubber roller) 8 Drum Forms images. 9 Transfer unit Transfers images onto the drum. 10 Pickup roller Picks up the manual feed paper. (In multi feed only) 11 Manual paper feed tray Tray for manual feed paper 12 Manual paper feed roller Transport the paper from the manual paper feed port. 13 PS roller unit Takes synchronization between the lead edge and the rear edge of the paper. 14 Paper feed roller Picks up a sheet of paper from the cassette. 15 Pickup roller Picks up documents. (ADF/RADF) 16 Separation roller Separates documents to feed properly. (ADF/RADF) 17 PS roller Feeds documents to the scanning section. (ADF/RADF) 18 Paper exit roller Discharges documents. (ADF/RADF) 14 351815 6 7 8 9 10 11121413 1617 2 e-STUDIO162_151.book 6 ページ 2004年12月2日 木曜日 午後9時37分
e-STUDIO162/162D/151/151D UNPACKING AND INSTALLATION 5 - 1 [5] UNPACKING AND INSTALLATION 1. Copier installation Improper installation may damage the copier. Please note the following during initial installation and whenever the copier is moved. Caution: If the copier is moved from a cool place to a warm place, con- densation may form inside the copier. Operation in this condi- tion will cause poor copy quality and malfunctions. Leave the copier at room temperature for at least 2 hours before use. Do not install your copier in areas that are: • damp, humid, or very dusty exposed to direct sunlight poorly ventilated subject to extreme temperature or humidity changes, e.g., near an air conditioner or heater. The copier should be installed near an accessible power outlet for easy connection. Be sure to connect the power cord only to a power outlet that meets the specified voltage and current requirements. Also make certain the outlet is properly grounded. Be sure to allow the required space around the machine for servicing and proper ventilation. 2. Cautions on handling Be careful in handling the copier as follows to maintain the perfor- mance of this copier. Do not drop the copier, subject it to shock or strike it against any object. Do not expose the drum cartridge to direct sunlight. Doing so will damage the surface (green portion) of the drum cartridge, causing poor print quality. Store spare supplies such as drum cartridges and TD cartridges in a dark place without removing from the package before use. If they are exposed to direct sunlight, poor print quality may result. Do not touch the surface (green portion) of the drum cartridge. Doing so will damage the surface of the cartridge, causing poor print quality. 3. Checking packed components and accessories Open the carton and check if the following components and accesso- ries are included. 8(20cm)8 (20cm) 4 (10cm)4 (10cm)Drum cartridge (installed in machine) Software CD-ROM • Operation manual Installation manualPower cord