Page 431
E- TRUNKS El- PORT NUMBER Description Use this option to change the port assignment for a trunk. The port is the hardware location of the trunk. When you change a trunk’s port number, all programming for the trunk goes to the new port assignment (location). All trunks use a single port. Keep the following in mind when programming ports: oUse HH- Port/Extension Checker to make sure each port has only one assigned trunk Do not swap an extension port with a trunk port. o You can optionally Use...
Page 432
E- TRUNKS CIRCUIT TYPE Description Use this option to identify the type of trunk connected to each trunk port. The trunk circuit type choices are: 05 OPX, and ports (see E- Extension programming) 07 DID trunk 08 CO trunk. ground start. 09 CO trunk, ground start, DP (Dial Pulse)’ 10 CO trunk, loop start. DTMF 11 CO trunk, loop start, DP 12 DISA trunk. DTMF, day or night* 13 DISA trunk, DP. day or 14 DISA trunk. DTMF. night only’ 15 DISA trunk. DP, night 16 Tie trunk, DTMF, wink 17 Tie trunk, DP,...
Page 433
E- TRUNKS CIRCUIT TYPE Feature Reference Instructions Step Step l Step 2 Step 3 l Refer to Programming in the following features: Background Music Centralized Attendant Central Office Calls. Answering Central Office Calls. Placing DP and DTMF Compatibility Direct Inward Dialing Direct Inward System Access Music On Hold Off-Premise Extension Paging Private Line Special Services and OCC Compatibility Tenant Service Tie Lines Voice Mail Compatibility To enter data on the PRF: Enter the circuit type...
Page 434
E- TRUNKS CIRCUIT NUMBER Description Related Programming l l l l Z-152 CONFIGURATIONIssue Use this option to assign the associated circuit number for each DID and tie trunk. Refer to the Installation and Programming Manual for charts and drawings that explain this association. This option does not . Conditions This option only applies to OPX. DID and tie trunks. Default Value No circuit number assigned (00). Centralized Attendant Service CP- Allow Bell Standard for CAS (BYO:O) Enable this...
Page 435
TRUNKS CIRCUIT NUMBER Related l l P P P Feature Reference Instructions Step Step l Step Issue 1-O KS- Programming for Each extension should have a line key for DID trunks or a loop key. Off-Premise Extension E- Trunks, Circuit Type OPX extensions use circuit type 05. Remember that OPX extensions use trunk numbers. Tie Lines CP- Absorb 1st Digit for DID and Tie Trunks For incoming wink start tie trunk calls, enable/disable 1st digit absorption. If enabled, system ignores first incoming...
Page 436
E- TRUNKS CLASS SERVICE Description Related Programming Feature Reference Instructions Step l Step Step 2 l Step 3 l Use this option to assign a Class of Service (COS) to each DID, DISA and tie trunk. You can use COS to put dialing restrictions on incoming DISA and tie trunk callers. Conditions This option only applies to DID, DISA and tie trunks. Default Value All trunks have COS 00. Refer to Programming in the features listed below. Refer to Programming in the following features: Centralized...
Page 437
E- TRUNKS NEXT TRUNK IN OUTBOUND ROTARY (HYBRID ONLY) Description Use this option to determine the selection sequence for trunks within a trunk rotary. The trunk rotary the order of the list vou create using this option. When entering data. make sure the last in the rotary not loop back to the first. You can program CO, DISA and tie trunks into an outbound rotary. Normally. only trunks of the same are in the same rotary. For example, to program a trunk rotary using trunks 480, 481 and 482: For...
Page 438
E- TRUNKS NEXT TRUNK IN OUTBOUND (HYBRID ONLY) Related Programming (Cont’d) l l Feature Reference Instructions Step 1 l Step 1 Step 2 Step 3 l Centralized Attendant Service CP- Allow Standard for Enable this option if hub system is using Bell Standard Centralized Attendant Service. Disable this option if hub is a PBX. E- Trunks, Circuit Type Assign each tie trunk used for CAS one of the following circuit types: 16 DTMF Wink Start tie line 17 Dial Pulse Wink Start tie line 18 DTMF Immediate...
Page 439
E- TRUNKS TRUNK SERVICE NUMBER Description Related Programming l If the system has ARS or LCR. use this option to assign a Service Number to trunks. Trunks of the same type should have the same Service Number. You can assign a trunk one of 10 Numbers (l-10). When routing calls, ARS and LCR will: Analyze the digits a user dials Choose a Number for the call Route the call on the first available trunk with the selected Service Number. You can also use this option to designate a trunk as a PBX trunk...
Page 440
E- TRUNKS TRUNK SERVICE NUMBER Related Programming (Cont’d) l Feature Reference Instructions Step l Step Step 2 l Step 3 QL- Codes, of Service Enter the type of service number (O-5). For example. for DDD or WATS, enter QL- Codes. Access Code For dial-up services. enter the access code (telephone number) for the service. QL- Codes, Code For dial-up services, enter the security code the service requires. QB- PBX Access Codes Designate up to 11 PBX access codes. Automatic Route Selection...