Page 451
E- TRUNKS EI- NIGHT CALL ROUTING Instructions Step Step 1 Step 2 Step 3 Voice Mail Compatibility E- Extensions, Circuit Type When connected to OPX or P/N 89748, each Voice Messaging System port should have circuit type 05. W-hen connected to AS1 P/N 89749, each Voice Messaging System port should have circuit type 5 1. E- Extensions, ES- Hunt Type Program each Voice Messaging System port with hunt type 06. E- Extensions, EA- UCD Group Master Extension Number Program each Voice Messaging System...
Page 453
E- TRUNKS EI- TANDEM TRUNK Description Related Programming Feature Reference Instructions Step Step 1 Step Use this option to enable Tandem Trunking capability for a trunk. Remember, only one of the trunks on a Tandem Call must have this option enabled. Conditions a. This option only applies to CO trunks. b. Tandem Trunking requires either loop start trunks with disconnect supervision or ground start trunks. Default Value Tandem trunking disabled (N). None Tandem Trunk To enter data on the PRF:...
Page 454
TRUNKS E TOLL RESTRICTION Description Related Programming Use this option to enable/disable Toll Restriction for each trunk. This only applies to Toll Restriction programmed using the AP- Toll Restriction and CP- Class of options. It does not apply to LCR and ARS. Conditions This option only applies to CO trunks. Although this option appears for DID trunks, it is not used. Default Value Toll Restriction enabled Toll Restriction AI- Initialize Toll Restriction Initialize Toll Restriction before...
Page 455
E- TRUNKS E J- TOLL RESTRICTION Feature Reference Toll Restriction Instructions To enter data on the PRF: Step Enable (Y) or disable Toll Restriction for each trunk on Table 5. To enter data at the programming terminal: Step 1 lType EJ. You see: 300 Step Enter the trunk number want to program and press RETURN. You see: TOLL RESTRICT Step 3 lEnter data for this option from Table and press RETURN.You advance to next consecutive trunk. Issue 1-OSOFTWARE CONFIGURATION2-169
Page 456
E- TRUNKS EL- LOOP NUMBER (ONYX IV) Description Related Programming l l Feature Reference Instructions Step 1 l Step 1 l Step 2 l Step 3 l Use this option to assign trunks to one of four loop numbers (l-4). Trunks ring the Attendant Console loop keys according to the trunk loop number and the loop key loop number. See Related Programming below. This option only applies to ONYX IV. Conditions None Default Value No loop number assigned (0). Trunks ring the 0 loop keys (if any). Attendant Console To program...
Page 457
E- TRUNKS EP- PRIORITY (ONYX IV) Description Related Programming Feature Reference Instructions Step l Step 1 Step Step 3 Issue 1-OUse this option to set the priority for trunks queued for busy Automatic Call Distribution groups. The range 00 (lowest priority) to 99 (highest priority). When an agent becomes free. the higher priority trunks are answered first. If waiting trunks the same ACD accepts calls FIFO (first in queue first out of queue). This option only applies to ONYX IV. Conditions...
Page 459
F- MISCELLANEOUS SYSTEM DATA F- EPROM CHECKSU MS Description Related Programming Feature Reference Instructions Step Step l Use this option to display the EPROM (memory circuit) checksums. The checksums provide a quick check of the software version of each memory circuit. Your service technician may ask for this information. Note that System Status Display the level of the SIM and In the large systems. this option displays the checksums of the EPROMS in the software cartridge. In a 56x120 or...
Page 460
F- MISCELLANEOUS SYSTEM DAT.4 ‘RESET SYSTEM QUEUES Description Related Programming l l Use this option to initialize (reset) the system queue elements. (HC- System Queues lists these elements.) This option’s primary use is to initialize the queue elements of each group, based on the order defined in programming. You should reset the system queues after you: Complete system installation programming Add an extension to an ACD or group Install or change your Voice Messaging System programming...