Page 451

 
E- TRUNKS
EI- NIGHT CALL ROUTING
Instructions
Step 
Step 1 
Step 2 
Step 3 
Voice Mail Compatibility
E- Extensions, 
 Circuit Type  When connected to OPX or  P/N
89748, each Voice Messaging System port should have circuit type 05. W-hen
connected to AS1 P/N 89749, each Voice Messaging System port should have
circuit type 5 1.
E- Extensions, ES- Hunt Type  Program each Voice Messaging System port
with hunt type 06.
E- Extensions, EA- UCD Group Master Extension Number  Program
each Voice Messaging System...

Page 452

E- TRUNKS
EI- NIGHT CALL ROUTING
For  
2-1   JR   

Page 453

E- TRUNKS
EI- TANDEM TRUNK
Description
Related
Programming
Feature Reference
Instructions
Step  
Step 1 
Step  
Use this option to enable Tandem Trunking capability for a trunk.
Remember, only one of the trunks on a Tandem Call must have this option
enabled.
Conditions
a. This option only applies to CO trunks.
b. Tandem Trunking requires either loop start trunks with disconnect
supervision or ground start trunks.
Default Value
Tandem trunking disabled (N).
None
Tandem Trunk
To enter data on the PRF:...

Page 454

 TRUNKS
E 
 TOLL RESTRICTION
Description
Related
Programming
Use this option to enable/disable Toll Restriction for each trunk. This only
applies to Toll Restriction programmed using the AP- Toll Restriction and
CP- Class of 
 options. It does not apply to LCR and ARS.
Conditions
This option only applies to CO trunks. Although this option appears for DID
trunks, it is not used.
Default Value
Toll Restriction enabled 
Toll Restriction
AI- Initialize Toll Restriction 
 Initialize Toll Restriction before...

Page 455

E- TRUNKS
E 
J- TOLL RESTRICTION
Feature Reference
Toll Restriction
Instructions
To enter data  on  the  PRF:
Step 
 Enable (Y) or disable  Toll Restriction for each trunk on Table 5.
To enter data at the programming terminal:
Step 1 lType EJ. You see:  300
Step  Enter the trunk number  want to program and press RETURN. You see:
TOLL RESTRICT
Step 3 lEnter data for this option from Table  and press RETURN.You advance to  next consecutive trunk.
Issue 1-OSOFTWARE CONFIGURATION2-169 

Page 456

E- TRUNKS
EL- LOOP NUMBER (ONYX IV)
Description
Related
Programming
l
l
Feature Reference
Instructions
Step 1 l
Step 1 l
Step 2 l
Step 3 l
Use this option to assign trunks to one of four loop numbers (l-4). Trunks
ring the Attendant Console loop keys according to the trunk loop number and
the loop key loop number. See Related Programming below. This option
only applies to ONYX IV.
Conditions
None
Default Value
No loop number assigned (0). Trunks ring the 0 loop keys (if any).
Attendant Console
To program...

Page 457

E- TRUNKS
EP- PRIORITY (ONYX IV)
Description
Related
Programming
Feature Reference
Instructions
Step  l
Step 1 
Step  
Step 3 
Issue 1-OUse this option to set the priority for trunks queued for busy Automatic Call
Distribution groups. The range 
 00 (lowest priority) to 99 (highest priority).
When an agent becomes free. the higher priority trunks are answered first. If
waiting trunks 
 the same  ACD accepts calls FIFO (first in queue
 first out of queue).
This option only applies to ONYX IV.
Conditions...

Page 458

E- TRUNKS 
EP- PRIORITY (ONYX IV)
 For   
   Issue  

Page 459

F- MISCELLANEOUS SYSTEM DATA
F- EPROM CHECKSU
MS
Description
Related
Programming
Feature Reference
Instructions
Step  
Step  l
Use this option to display the  EPROM (memory circuit) checksums.
The checksums provide a quick check of the software version of each memory
circuit. Your service technician may ask for this information. Note that 
System Status Display  the  level of the   SIM
 and 
In the large systems. this option displays the checksums of the EPROMS in
the software cartridge.
In a 56x120 or...

Page 460

F- MISCELLANEOUS SYSTEM DAT.4
 ‘RESET SYSTEM QUEUES
Description
Related
Programming
l
l
Use this option to initialize (reset) the system queue elements. (HC- System
Queues lists these elements.) This option’s primary use is to initialize the
queue elements of each 
 group, based on the order defined in
programming.
You should reset the system queues after you:
 Complete system installation programming
 Add an extension to an ACD or  group
 Install or change your Voice Messaging System programming...