T-1/ISDN Alarm Programming 2-293
Chapter 2 - Features and Operation
Minor Alarm
Description
If the error counter for an Alarm Code reaches the number programmed as a Minor Alarm 
within the time (in minutes) entered in the Time Period, the system reports a Minor Alarm 
condition. The Minor Alarm threshold setting is variable from 00 to 99 minutes.
Programming Steps
1. Press the MINOR ALARM flexible button (FLASH 47, Button #13). Button #13 LED is lit 
steady. The following message displays:
2. Enter a...

Page 322

2-294 T-1 /IS D N Al a rm  P ro g ram mi n g
Chapter 2 - Features and Operation
Time Period
Description
The Time Period option represents the length of time set for Minor and Major alarm 
conditions to occur.
Programming Steps
1. Press the TIME PERIOD flexible button (FLASH 47, Button #15). Button #15 LED is lit 
steady. The following message displays:
2. Enter a valid number (00-99) on the dial pad which represents the time period limit.
3. Press the HOLD button to save the entry. A confirmation tone...

Page 323

Text Messaging (Silent Response) 2-295
Chapter 2 - Features and Operation
Text Messaging (Silent Response)
Description
The Text Messaging feature allows a station user to use text messages to respond to a caller 
that has either camped-on or has used the off-hook voice over (OHVO) feature to alert a busy 
station of a waiting call or message. The camped-on station may respond to the caller via the 
canned, custom, and silent response text (LCD) messages. The text messages appear on the 
calling party LCD...

Page 324

2-296Toll Restriction
Chapter 2 - Features and Operation
» A station can receive only one message at a time.
» Text messages may be chained (i.e., multiple messages sent to one caller).
» Text message responses appear on the calling station and the receiving station (station 
activating text responses) LCD displays.
» If the calling station is a non-LCD telephone, the receiving station receives error tone 
when responding via text messaging.
» The receiving station may press a flexible button programmed...

Page 325

Toll Restriction2-297
Chapter 2 - Features and Operation
The Station COS interacts with CO Line COS assignments to provide several different types of 
dialing privileges.
The Allow and Deny tables enable entries of either general or specific allow and deny codes 
such as allowing all [1-800] type calls, and/or denying all [1]+ or [0]+ calls.
The Allow and Deny tables allow a maximum of 8 digits to be entered as allow or deny digits. 
This enables entry of certain area codes or office codes that can...

Page 326

2-298Toll Restriction
Chapter 2 - Features and Operation
A special Do Not Care character (D) may be entered to allow or deny any digit dialed in 
that digit sequence.
Special Reference Tables
The XTS system also offers four special tables that can be referenced from within the two 
Allow Tables.
Three of the special tables can be assigned to specific area codes that require further toll 
restriction definition.
The fourth Special Table is reserved for use as a home area code table (numbers within 
the...

Page 327

Toll Restriction2-299
Chapter 2 - Features and Operation
E n t e r i n g  To l l  Ta b l e
Description
All toll tables have been conveniently placed under one program code to allow entry of all 
toll restriction data.
The buttons on the digital terminal are defined as shown below when entering the Toll 
Restriction programming area (FLASH 70):
When the system searches the Allow and Deny tables, the entries are checked starting with 
Bin 01 and proceeding sequentially through the table to the last bin. In...

Page 328

2-300Toll Restriction
Chapter 2 - Features and Operation
3. To program Special Tables 1-3, it is necessary to associate an area code to the table. This is 
done by pressing the appropriate AREA CODE TABLE button and assign the area code.
4. To display entries in any of the tables, press the DISPLAY TABLES button (FLASH 70, 
Button #12). Entries in the Allow/Deny tables display two at a time. Entries in the Special 
tables display six at a time in ascending order.
Allow Table
Description
Each Allow Table...

Page 329

Toll Restriction2-301
Chapter 2 - Features and Operation
The entry into the Allow Table would be entered as follows:
Leading Digit [1]: Enter [BB] [1] [XXX] [DDD] [S]
-or-
Non-Leading [1]: Enter [BB] [XXX] [DDD] [S]
BB = Bin Number (Bins 17-19)
XXX = Area Code (must match AREA-X entry)
DDD = Do Not Care digit (three entries, DND button)
[S] = Search Special Table Command (TRANS button)
For an entry that references the Home Area Code table (Special Table 4) the entry may also be 
entered to expect or...

Page 330

2-302Toll Restriction
Chapter 2 - Features and Operation
To erase a bin number:
1. Enter a valid bin number.
2. Press the HOLD button.
Deny Table
Description
Each Deny Table contains ten bin numbers. Each bin number may be up to eight-digits 
including {Do Not Care} digits. Entries in the Deny Table represent numbers or codes that are 
to be denied or restricted. Common entries would be [1] for restricting all [1+] type of calls. 
Exceptions to this restriction would be entered into the Allow Table....