Home > Siemens > Communications System > Siemens Saturn Iie Epabx General Description Manual

Siemens Saturn Iie Epabx General Description Manual

Here you can view all the pages of manual Siemens Saturn Iie Epabx General Description Manual. The Siemens manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 271

I 
- 
SATURN IIE EPABX A30808-X5130-B120-l-8928 
Installation Test Procedures Issue 1, May 1986 
NOTES: 
* These feature buttons are not testable. 
Buttons 9 through 13 do not contain LEDs. 
Figure 6.21 Siemeno JR-DYAD Telephone Button Depression Sequence 
6-23  

Page 272

I . I 
- 
SATURN IIE EPABX 
Installation Test Procedures A30808-X5130-B120-l-8928 
Issue 1, May 1986 
Table 6.09 Siemens Digital Telephone -DYAD Display Test 
NOTES: 1) If the system 
option flag TSTDIAG has been enabled in the data base or the Siemens Digital Telephone under 
test is classmarked with TSTAPP feature, the maintenance test phone is not required to enable or disabie the 
Apparatus Diagnostic routines; therefore, perform only steps 5 through 9. 
2) If the system option flag TSTDIAG has been...

Page 273

i . 
I 
SATURN IIE EPABX 
A30808-X5130-B120-l-6928 
Installation Test Procedures 
Issue 1, May 1986 
Table 6.10 Siemens Digital Telephone Displayable Characters 
ORDER CHARACTER 
ORDER CHARACTER 
1. ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 33. 
AAAAAAAAAAAAAAAA 
2. #P It It I, I, ,I 0 0 I, r, 0 I, 0 I, ,I I, 34, BBBBBBBBBBBBBBBB 
3. #H#H#####,Y###### 35. cccccccccccccccc 
4. $ssssss$s$s$s$s$ 36. DDDDDDDDDDDDDDDD 
5. o/b 010 vo %%%% vo vo o/o %% o/o %% o/o 
37. EEEEEEEEEEEEEEEE 
6. &&&&&&&&&&.&&&&&& 38....

Page 274

SATURN IIE EPABX 
‘nstallation Test Procedures 
Table 6.11 Outgoing Trunk Test A30808-X5130-8120-l-8928 
Issue 1, May 1986 
STEP 
1 
5 
6 
7 
8A 
8B PROCEDURE VERlFiCATlCN 
?lace maintenance test phone 
off-hook. 
Dial the Diagnos?ic Test Access Code. 
Dial 2 to enable trunk test. 
Dial the two-digit trunk group number 
(00 through 31) coniaining the trunk 
circuit to be tested. 
Dial the two-digit trunk number (00 - 
99) of the trunk circuit to be tested. 
For CO-type trunks (i.e., TMBM PCB), 
dial the...

Page 275

- 
SATURN IIE EPABX A30i308-X5130-B120-1-B928 
Installation Test Procedures Issue 1, May 1986 . 
Table 6.12 Placing Circuit(s) In-Service 
STEP PROCEDURE VERIF!CATION IF VERlFlCATIOfl 
IS NOT OBTAiNED * 
1 Place maintenance test phone Dial tone is returned. 
off-hook. 
2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 
3 Dial 7 for placing a circuit in-service. None. 
4A If a single circuit is to be placed in- Coniirmation tone is returned. If reorder tone is returned, the seleci-...

Page 276

I ’ 
SATURN IIE EPABX 
installation Test Procedures 
Table 6.13 Takinq Circuit(s) Out-of-Service IContinucdl 
A30808-X5130-8120-1-8928 
Issue 1, May 1986 
. , 
STEP 
PROCEDURE VERIFICATION IF VERIFICATION 
IS NOT OBTAINED 
5A 
If additional tests or procedures are Recall dial tone is returned. 
to be performed, hook-flash the main- 
tenance test phone and dial the next 
code (Diagnostic Test Access Code is 
not redialed). 
5B If no additional tests or procedures are None. 
to be performed place the main-...

Page 277

I 
.-- 
SATURN IIE EPABX 
A30808-X5130-B120-143928 
Installation Test Procedures Issue 1, May 1986 
SECTKIN 7.00 INSTALLATION TEST PROCEDURES CHECKLlST 
7.01 General. After performing the installation test proce- 
dures contained in this practice, each installation test proce- 
dure performed should be recorded to ensure that all tests have been completed satisfactorily. Use Table 7.00, Installa- 
iion Test. Procedures Checklist, for this purpose. This table 
can be used as a sign-off sheet, if required....

Page 278

Siemens Pracltces 
Maintenance Series A30808-X5130-DllO-18920 
Issue 1, May 1986 
SATURN” IIE EPABX 
MAINTENANCE AND TWQU 
ESH~O=~I 
Issued by Office Systems Group 
5500 Broken Sound Boulevard N.W.. Boca Raton. Florida 33431 
- - .-_ .~__- - 
Stemens lnformatlon Systems, Inc. (305) 994-8100 l Telex: 515052 
Printed in U.S.A.  

Page 279

Siemens Practices 
,.’ Maintenance Series A30808-X5130-DIIO-l-8920 
Issue 1, May 1986 
0 Siemens Information Systems, inc., 1985 
All rights reserved. 
- i 
I 
-: 
This material is proprietary to Siemens Information Systems, Inc. Any unauthorized 
reproduction, use or disclosure of this material, or any part thereof, is strictly prohibited. 
Siemens reserves the right to make changes in specifications at any time and without 
notice. The information furnished by Siemens in this material is believed to be...

Page 280

SAUTRN IIE EPABX  A30808-X5130-DllO-l-8920 
Maintenance  and Troubleshooting  Issue 
1, May  1986 
CONTENTS  I 
--. 
SECTION  PAGE 
FIGURE  PAGE 
................. ....... l-l 
Purpose..  .......................  ...... 
1-l 
Scope  ...........................  ......  l-l 
Siemens  SATURN  IIE Practices  ......  ......  1-l 
Siemens  Customer  Support Services  ...... 
l-l 
What  to Do  in Case  of Trouble  with 
FCC-Registered  Equipment, ....... 
. l-l 
2.00  MAINTENANCE  OVERVIEW ...................
Start reading Siemens Saturn Iie Epabx General Description Manual

Related Manuals for Siemens Saturn Iie Epabx General Description Manual

All Siemens manuals