I - SATURN IIE EPABX A30808-X5130-B120-l-8928 Installation Test Procedures Issue 1, May 1986 NOTES: * These feature buttons are not testable. Buttons 9 through 13 do not contain LEDs. Figure 6.21 Siemeno JR-DYAD Telephone Button Depression Sequence 6-23
Page 272
I . I - SATURN IIE EPABX Installation Test Procedures A30808-X5130-B120-l-8928 Issue 1, May 1986 Table 6.09 Siemens Digital Telephone -DYAD Display Test NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the Siemens Digital Telephone under test is classmarked with TSTAPP feature, the maintenance test phone is not required to enable or disabie the Apparatus Diagnostic routines; therefore, perform only steps 5 through 9. 2) If the system option flag TSTDIAG has been...
Page 273
i . I SATURN IIE EPABX A30808-X5130-B120-l-6928 Installation Test Procedures Issue 1, May 1986 Table 6.10 Siemens Digital Telephone Displayable Characters ORDER CHARACTER ORDER CHARACTER 1. ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 33. AAAAAAAAAAAAAAAA 2. #P It It I, I, ,I 0 0 I, r, 0 I, 0 I, ,I I, 34, BBBBBBBBBBBBBBBB 3. #H#H#####,Y###### 35. cccccccccccccccc 4. $ssssss$s$s$s$s$ 36. DDDDDDDDDDDDDDDD 5. o/b 010 vo %%%% vo vo o/o %% o/o %% o/o 37. EEEEEEEEEEEEEEEE 6. &&&&&&&&&&.&&&&&& 38....
Page 274
SATURN IIE EPABX ‘nstallation Test Procedures Table 6.11 Outgoing Trunk Test A30808-X5130-8120-l-8928 Issue 1, May 1986 STEP 1 5 6 7 8A 8B PROCEDURE VERlFiCATlCN ?lace maintenance test phone off-hook. Dial the Diagnos?ic Test Access Code. Dial 2 to enable trunk test. Dial the two-digit trunk group number (00 through 31) coniaining the trunk circuit to be tested. Dial the two-digit trunk number (00 - 99) of the trunk circuit to be tested. For CO-type trunks (i.e., TMBM PCB), dial the...
Page 275
- SATURN IIE EPABX A30i308-X5130-B120-1-B928 Installation Test Procedures Issue 1, May 1986 . Table 6.12 Placing Circuit(s) In-Service STEP PROCEDURE VERIF!CATION IF VERlFlCATIOfl IS NOT OBTAiNED * 1 Place maintenance test phone Dial tone is returned. off-hook. 2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 3 Dial 7 for placing a circuit in-service. None. 4A If a single circuit is to be placed in- Coniirmation tone is returned. If reorder tone is returned, the seleci-...
Page 276
I ’ SATURN IIE EPABX installation Test Procedures Table 6.13 Takinq Circuit(s) Out-of-Service IContinucdl A30808-X5130-8120-1-8928 Issue 1, May 1986 . , STEP PROCEDURE VERIFICATION IF VERIFICATION IS NOT OBTAINED 5A If additional tests or procedures are Recall dial tone is returned. to be performed, hook-flash the main- tenance test phone and dial the next code (Diagnostic Test Access Code is not redialed). 5B If no additional tests or procedures are None. to be performed place the main-...
Page 277
I .-- SATURN IIE EPABX A30808-X5130-B120-143928 Installation Test Procedures Issue 1, May 1986 SECTKIN 7.00 INSTALLATION TEST PROCEDURES CHECKLlST 7.01 General. After performing the installation test proce- dures contained in this practice, each installation test proce- dure performed should be recorded to ensure that all tests have been completed satisfactorily. Use Table 7.00, Installa- iion Test. Procedures Checklist, for this purpose. This table can be used as a sign-off sheet, if required....
Page 278
Siemens Pracltces Maintenance Series A30808-X5130-DllO-18920 Issue 1, May 1986 SATURN” IIE EPABX MAINTENANCE AND TWQU ESH~O=~I Issued by Office Systems Group 5500 Broken Sound Boulevard N.W.. Boca Raton. Florida 33431 - - .-_ .~__- - Stemens lnformatlon Systems, Inc. (305) 994-8100 l Telex: 515052 Printed in U.S.A.
Page 279
Siemens Practices ,.’ Maintenance Series A30808-X5130-DIIO-l-8920 Issue 1, May 1986 0 Siemens Information Systems, inc., 1985 All rights reserved. - i I -: This material is proprietary to Siemens Information Systems, Inc. Any unauthorized reproduction, use or disclosure of this material, or any part thereof, is strictly prohibited. Siemens reserves the right to make changes in specifications at any time and without notice. The information furnished by Siemens in this material is believed to be...
Page 280
SAUTRN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 CONTENTS I --. SECTION PAGE FIGURE PAGE ................. ....... l-l Purpose.. ....................... ...... 1-l Scope ........................... ...... l-l Siemens SATURN IIE Practices ...... ...... 1-l Siemens Customer Support Services ...... l-l What to Do in Case of Trouble with FCC-Registered Equipment, ....... . l-l 2.00 MAINTENANCE OVERVIEW ...................