Page 311
SATURN IIE EPABX Maintenance and TroubleshootIng A30808-X5130-DllO-l-6920 Issue 1, May 1986 I - 5. Memory Support Module (MSM). The MSM is an optional module which provides +SVdc (+5VB) with internal battery back-up for the memory chips in the memory (MEMS and MEM4) PCBs in the common equipment section of the Basic Shelf. The MSM contains a linear regulator and battery charg- er, a battery, and sensing circuits to detect power failure, battery overvoltage, and battery failure. Pro- tection...
Page 312
I - SATURN IIE EPAEX Maintenance and Troubleshooting A30808-X5130-DllO-l-6920 Issue 1, May 1986 SECTION 3.00 PREVENTIVE MAINTENANCE 3.01 General. The following general-type service routines are suggested for proper upkeep of the SATURN IIE EPASX. The service routines should be performed on an annual ba- sis unless otherwise specified. a. Hardware and Cabling. Check for general mechani- cal integrity, no loose or broken parts and connectors. Tighten or repair as necessary. b. Cabinet...
Page 313
I - SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 SECTION 4.00 TROUBLESHOOTING AND REWUR PROCEDURES 4.01 General. This section of the practice provides step-by- step instructions for the troubleshooting and repair of mal- functions or failures during precutover or postcutover of the SATURN IIE EPABX. WARNING Hazardous voltages exist wirhin the equipment cabinet. Be extremely careful when performing maintenance and troubleshooting procedures wirh...
Page 314
P SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Table 4.00 PCB and Power Supply Removal Guidelines MODULE OR UNIT SERVICE STATE SPECIAL INSTRUCTIONS CIOP NA CONF NA DTMF 00s FDDO, FDDl NA LTUC . NA LTUPS l NA MCA NA MEM3 NA MEM4 NA MSM . NA MSM Battery l ES PIMD PSC PSU K RAUP NA SlAl6 00s SLMA-0 00s SLMA-S 00s SLMD 00s SMXTG NA TM BA-2 00s TMBA-4 00s TMBM 00s TMIE 00s -48PS0 NA -48PSl . NA . Optional depending upon...
Page 315
- SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-8920 Issue 1, May 1986 ,,- Table 4.01 Failure Indications on Controller/Input-Output Processer Printed Circuit Board, CIOP ZTO ’ ST1 ST2 ’ ST3 HEX LED /’ LED 3, LED LED CODE ERROR DETECTED ACTION / OFF OFF OFF 0 Start of self test noi halted None OFF OFF ON 1 Main processor error Note 1 OFF OFF OFF :: ON 2 EPROM checksum error Note 1 OFF OFF 3 MEMO slot low 64k test error Notes 1 and 2 OFF ON OFF OFF 4 8k by 8static...
Page 316
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting issue 1. May 1986 Table 4.02 Alarm Reporting and Processing ALARM TYPE CORRECTIVE ACTION a. AUDIT eeee(pp) aaaa bbbb cccc dddd mm/dd hh:mm eeee = error number (PP)’ = ID of process aaaa’ = error information bbbb’ = error information cccc* = error information dddd’ = error information mm/dd = date of error hh:mm = time of error (1) If eeee = 1428 The memory contents audit routine has detected a check- sum error in...
Page 317
I - SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE CORRECTIVE ACTION aa = l/O device and associated PCB identity number bb = Device return code (4) If eeee = 1468 l * aa I/O Device PCB 00 Floppy Disk Drive 1 CIOP 01 Floppy Disk Drive 2 CIOP 02 Floppy Disk Drive 3 _ CIOP 03 Service Term’l(TTY) CIOP 04 RS232C CH 0 (TTYO) RAUP 05 RS232C CH 1 (TTYl) RAUP 06 Modem RAUP...
Page 318
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE (7) If eeee = 1472 ** CORRECTIVE ACTION Data device audit error (bad path). The identified data device passed the peripheral interface loopback (LB5) test run by the data device audit routine, but failed the remote channel loopback (LB3) test. Possible trouble sources: (1) Faulty data device (DCI). (2) Faulty cabling from SLMD to DCI....
Page 319
SATURN IIE EPABX Maintenance and Troubleshooting Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE c. DISCONNECT 1440(18) PEN = wxyz mm/dd hh:mm 1440 = error number WY = ID of process wxyz = PEN mm/dd = date of error hh:mm = time of error CORRECTIVE ACTION MTS audit failure. The MIS (time switch) audit routine has detected a possi- ble port failure on the MCA PCB when attempting to con- nect the specified port to quiet tone. If the problem is repetitive, the MCA PCB should...
Page 320
Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE CORRECTIVE ACTION f. LTU FAILURE (18) PEN’S LTU (or Basic Shelf) clock failure error. aaaa TO bbbb mm/dd hh:mm The identified shelf and LTUC (where applicable) has lost (W’ = ID of process communication with the CE. The error may be a result of aaaa = 1st number in range of PENS affected the following: by failure bbbb = last number in range of PENS affect- (1) Blown shelf fuse on the PSU front panel. ed by failure mm/dd = date of...