A30806X5130-DllO-l-8920 Issue 1, May 1986 Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE (1) If eeee = 1405 CORRECTIVE ACTION Correctable memory parity error on a MEM3 or MEM4 PCB. A parity error was detected and corrected on the MEM3 or MEM4 PCB as identified by the slot number in this error message. If the problem occurs more than once in a single week, the identified memory PCB should be replaced. NOTE: The slot number identity of the faulty memory PCB is provided in the...
Page 322
SATURN IIE EPABX Maintenance and Troubleshooting Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE CORRECTIVE ACTION i. MEM PROT (pp) LOC=aaaa:bbbb The main processor attempted to write into protected ADDR=cccc:dddd mm/dd hh:mm memory. (PP)’ = ID of process If problem is repetitive, consult Siemens field service aaaa: representative. bbbb’ = error information cccc: dddd’ = error information mmldd = date of error hh:mm = time of error NOTE: For reference only, the error number...
Page 323
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Table 4.02 Alarm Reportinq and Processinq (Continued) - . ALARM TYPE CORRECTIVE ACTION NOTE: This error also occurs when a PIMD or SLMD PCB is removed without first taking it out-of-service. Possible trouble sources: (1) Faulty console, SDT, or DCI. (2) Faulty cabling between apparatus and PIMD or SLMD PCB. (3) Faulty PIMD or SLMD PCB. (4) Faulty SMXTG PCB if PEN indicates Basic Shelf; faulty LTUC...
Page 324
SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-B920 Issue 1, May 1986 Table 4.02 Alarm Reporting and Processing (Continued) r ALARM TYPE CORRECTIVE ACTION 1. RELOAD : MANUAL RESET (pp) A system reload,-initiated via the CIOP Reset pushbutton, mm/dd hh:mm has been completed. (PP)’ = ID of process mm/dd = date of error This message is followed by a ‘S&V TRAP” message in- hh:mm = time of error dicating the type of recovery (i.e., a reload). NOTE: For reference only, the error...
Page 325
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE CORRECTIVE ACTION s. RESTART : POWER FAILURE (pp) In an MSM equipped system, a hard restart has been in- mm/dd hh:mm itiated and completed due to a momentary power loss. The rn!ZZ = ID of process MSM maintained the +SVdc power input to the memory = date of error PCBS. hh:mm = time of error This message is followed by a “S/W TRAP” message in-...
Page 326
SATURN IIE EPABX Maintenance and Troubleshooting Table 4.02 Alarm Reporting and Processing (Continued) ALARM TYPE (2) If eeee = 1300 CORRECTIVE ACTION System restart marker. This error entry logs the date and time whenkver the system goes through a system restart (recovery). Analyze the errors preceding this error to determine the cause of the restart. NOTE: The type of restart is identified in the following error message: “SNV TRAP 1300 (05) aaaa bbbb cccc dddd mmldd hh:mm” aaaa = type of...
Page 327
I - SATURN IIE EPABX Maintenance and Troubleshoohng Table 4 rXJ Alarm Reoortino and Processino (Continued) A30808-X5130-DllO-l-8920 Issue 1, May 1986 _____ ..__ _.._.... .._r _..... ~ -..- ----- . .._ ,-- ---, ALARM TYPE CORRECTIVE ACTION If the prpbtem is intermittent, the system reload may clear the intermittent condition. If a hard failure (or repet&e intermittent failures) occurs, possible sources of the trouble are: (1) Faulty SMXTG PCB. . (2) Faulty CIOP PCB. (6) If eeee = 1444 Disk...
Page 328
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Table 4.02 Alarm Reporting and Processing (Continued) AI ARM TVPF CORRECTIVE ACTION . .-. . . . . . . . - This message is followed by “RELOAD : POWER FAILURE” and “S/W TRAP” messages (1489 and 1300) respectively, indicating the type and time of the recovery. If system reloads resulting in these error messages are repetitive: 1. Replace MEM3 and MEM4 PCBs. 2. Verify MSM operation. 3. Consult Siemens...
Page 329
I - SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-8920 Issue 1, May 1986 Table 4.03 Failure Indications on LTUC Printed Circuit Board LED PUS PRS ALMO ALMO LED STATUS Dark Lighted l Dark Lighted l ALMl Dark PROBABLE CAUSE No failures are detected LTUC is not communicating with common control: +12Vdc undervoltage, -5Vdc undervoltage, or -48Vdc undervottage NOTE: When the system is reloading and common control is inactive, the PRS LED on each LTUC PCB lights...
Page 330
A30808-X5130-DllO-l-6920 Issue 1, May 1986 I -- SATURN IIE EPABX Maintenance and Troubleshooting 4.06 Power Failures. When a loss of power is suspected to be the cause of failures in the system, the craftsperson should follow the guidelines described below. (Refer to para- graph 2.15, Power Distribution and Failures, for descriptive information on the power supplies.) l Visually check the PSU front panel (Figure 2.01) for blown fuses and tripped circuit breakers. Refer to para- graph 4.06a....