Siemens Saturn Iie Epabx General Description Manual
Here you can view all the pages of manual Siemens Saturn Iie Epabx General Description Manual. The Siemens manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 341
A30808-X5130-DllO-l-8920 Issue 1, May 1986 I SATURN ItE EPABX Maintenance and Troubleshoohng (2) If the circuit remains in the out-of-service - automatic state, continue with step 2. 2. Using the ALMDATA CMU Procedure, check the Failure History Memory for system alarm mes- sages. The corrective repair procedures for system alarm messages are provided in Table 4.02. 3. If more than one SDT fails at the same time, (a) If all affected SDTs are assigned to the same SLMD PCB, replace the PCB. (b)...
Page 342
, SATURN IIE EPABX Maintenance and Troubleshooting (b) 03 If out-of-service - craft, return the circuit to the in-service state (Table 4-lo), and verify opera- tion. Continue with step 2 if the SDT remains inoperative. If out-of-service - automatic, attempt to return the circuit to the in-service state (Table 4-10). (1) If circuit returns to the in-service state and the failure clears, the problem was tran- sient. If transient problems recur on the same circuit, continue with step 2. (2) If...
Page 343
SATURN IIE EPABX Maintenance and Troubleshooting Table 4.06 Tone Generator Test STEP PROCEDURE VERIFICATION IF VERIFICATION IS NOT OBTAINED , - 1 Place maintenance test phone off-hook. Dial tone returned. 2 Dial the Diagnostic Test Access Code. Recall dial tone returned. 3 Dial 1 for tone generator test. None. 4A Dial 00 if all tones are to be tested and All tones are returned in the sequence If any tone(s) is returned distorted, retry verify that all tones returned are un- shown in Table 4.07...
Page 344
A30808-X5130-DllO-l-6920 Issue 1, May 1986 Table 4.08 Outgoing Trunk Test STEP PROCEDURE VERIFICATION IF VERIFICATION IS NOT OBTAINED 1 Place maintenance test phone Dial tone is returned. off-hook. 2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 3 Dial 2 to enable trunk test. None. 4 Dial the two-digit trunk group number None. (00 through 31) containing the trunk circuit to be tested. 5 Dial the two-digit trunk number (00 - CO or PABX dial tone is returned. Also, If...
Page 345
+ I -. SATURN IIE EPABX Maintenance and Troubleshooting Table 4.09 DTMF Receiver Test STEP PROCEDURE VERIFICATION 6A 6B STEP PROCEDURE VERIFICATION 1 2 3 4A 4B Place maintenance test phone off-hook. Dial the Diagnostic Test Access Code. Dial #f for DTMF receiver test. Dial the four-digit PEN of the DTMF receiver circuit to be tested. Depress the maintenance test phone keypad buttons in the following se- quence. a. For 12-button phones: 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, * and #. b....
Page 346
-. Table 4.10 Placing Circuit(s) In-Service (Continued) STEP 5A STEP PROCEDURE VERIFICATION 1 2 3 4A 48 5A 58 PROCEDURE If additional tests or procedures are to be performed, hook-flash the main- tenance test phone and dial the next code ( Diagnostic Test Access Code is not redialed). If no additional tests or procedures are to be performed, place the main- tenance test phone on-hook. I VERlFlCATlON Recall dial tone is returned None. Table 4.11 Taking Circuit(s) Out-of-Service...
Page 347
, SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-8920 Issue 1, May 1986 Table 4.12 DTMF Dial Pad Test NOTES: 1. If the system option flag TSTDIAG has been enabled in the data base or the station under test is class-marked with the TSTAPP feature, the maintenance test phone is not required to enable or disable the Apparatus Test routines; therefore, perform steps 5 through 8. 2. If the system option flag TSTDIAG has been disabled in the data base or the station under test is...
Page 348
SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-8920 Issue 1, May 1986 Table 4.13 Station Line Test NOTES: 1. If the system option flag TSTDIAG has been enabled in the data base or the.station under test is class-marked with the TSTAPP feature, the maintenance test phone is not required to enable or disable the Apparatus Diag- nostic -Test routines; therefore, perform steps 5 through 10. 2. If the system option flag TSTDIAG has been disabled in the data base or the station...
Page 349
SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-6920 Issue 1, May 1986 pyyq 6 7 8 9 10 ==m -- l I I I Flb.5” = 31 T E 32 ANS IT , 1 a I I , 11 12 13 14 15 w 26 27 28 29 30 Figure 4.05 Attendant Console Keypad and Feature Button Depression Sequence 4-37
Page 350
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Table 4.14 Attendant Console Test , STEP PROCEDURE VERIFICATION IF tiERtFlcATi0~ IS NOT OBTAINED 1 Place maintenance test phone off-hook. Dial tone is returned. 2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 3 Dial 3 to enable the Apparatus Tests. Confirmation tone is returned. 4 Place maintenance test phone on-hook. None 5 At the Console under test, dial the At- Recall dial tone is...