Page 341

A30808-X5130-DllO-l-8920 
Issue 1, May 1986 I 
SATURN ItE EPABX 
Maintenance and Troubleshoohng 
(2) If the circuit remains in the out-of-service 
- automatic state, continue with step 2. 
2. Using the ALMDATA CMU Procedure, check the 
Failure History Memory for system alarm mes- 
sages. The corrective repair procedures for system 
alarm messages are provided in Table 4.02. 
3. If more than one SDT fails at the same time, 
(a) If all affected SDTs are assigned to the same 
SLMD PCB, replace the PCB. 
(b)...

Page 342

, 
SATURN IIE EPABX 
Maintenance and Troubleshooting 
(b) 
03 If out-of-service - craft, return the circuit to the 
in-service state (Table 4-lo), and verify opera- 
tion. Continue with step 2 if the SDT remains 
inoperative. 
If out-of-service - automatic, attempt to return 
the circuit to the in-service state (Table 4-10). 
(1) If circuit returns to the in-service state and 
the failure clears, the problem was tran- 
sient. If transient problems recur on the 
same circuit, continue with step 2. 
(2) If...

Page 343

SATURN IIE EPABX 
Maintenance and Troubleshooting 
Table 4.06 Tone Generator Test 
STEP PROCEDURE VERIFICATION IF VERIFICATION 
IS NOT OBTAINED , 
- 
1 Place maintenance test phone off-hook. Dial tone returned. 
2 Dial the Diagnostic Test Access Code. Recall dial tone returned. 
3 Dial 1 for tone generator test. None. 
4A Dial 00 if all tones are to be tested and All tones are returned in the sequence If any tone(s) is returned distorted, retry 
verify that all tones returned are un- shown in Table 4.07...

Page 344

A30808-X5130-DllO-l-6920 
Issue 1, May 1986 
Table 4.08 Outgoing Trunk Test 
STEP PROCEDURE VERIFICATION IF VERIFICATION 
IS NOT OBTAINED 
1 Place maintenance test phone Dial tone is returned. 
off-hook. 
2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 
3 Dial 2 to enable trunk test. None. 
4 Dial the two-digit trunk group number None. 
(00 through 31) containing the trunk 
circuit to be tested. 
5 Dial the two-digit trunk number (00 - CO or PABX dial tone is returned. Also, If...

Page 345

+ 
I 
-. 
SATURN IIE EPABX 
Maintenance and Troubleshooting 
Table 4.09 DTMF Receiver Test 
STEP PROCEDURE VERIFICATION 
6A 
6B 
STEP PROCEDURE VERIFICATION 
1 
2 
3 
4A 
4B Place maintenance test phone 
off-hook. 
Dial the Diagnostic Test Access Code. 
Dial #f for DTMF receiver test. 
Dial the four-digit PEN of the DTMF 
receiver circuit to be tested. 
Depress the maintenance test phone 
keypad buttons in the following se- 
quence. 
a. For 12-button phones: 1, 2, 3, 4, 
5, 6, 7, 8, 9, 0, * and #. 
b....

Page 346

-. 
Table 4.10 Placing Circuit(s) In-Service (Continued) 
STEP 
5A 
STEP PROCEDURE VERIFICATION 
1 
2 
3 
4A 
48 
5A 
58 PROCEDURE 
If additional tests or procedures are 
to be performed, hook-flash the main- 
tenance test phone and dial the next 
code ( Diagnostic Test Access Code 
is not redialed). 
If no additional tests or procedures 
are to be performed, place the main- 
tenance test phone on-hook. 
I 
VERlFlCATlON 
Recall dial tone is returned 
None. 
Table 4.11 Taking Circuit(s) Out-of-Service...

Page 347

, 
SATURN IIE EPABX 
Maintenance and Troubleshooting A30808-X5130-DllO-l-8920 
Issue 1, May 1986 
Table 4.12 DTMF Dial Pad Test 
NOTES: 1. If the system option flag TSTDIAG has been enabled in the data base or the station under test is class-marked 
with the TSTAPP feature, the maintenance test phone is not required to enable or disable the Apparatus Test 
routines; therefore, perform steps 5 through 8. 
2. If the system option flag TSTDIAG has been disabled in the data base or the station under test is...

Page 348

SATURN IIE EPABX 
Maintenance and Troubleshooting A30808-X5130-DllO-l-8920 
Issue 1, May 1986 
Table 4.13 Station Line Test 
NOTES: 1. If the system option flag TSTDIAG has been enabled in the data base or the.station under test is class-marked 
with the TSTAPP feature, the maintenance test phone is not required to enable or disable the Apparatus Diag- 
nostic -Test routines; therefore, perform steps 5 through 10. 
2. If the system option flag TSTDIAG has been disabled in the data base or the station...

Page 349

SATURN IIE EPABX 
Maintenance and Troubleshooting A30808-X5130-DllO-l-6920 
Issue 1, May 1986 
pyyq 
6 
7 8 9 10 ==m 
-- 
l I I I Flb.5” 
= 
31 T 
E 
32 ANS 
IT 
, 1 a I 
I , 11 12 13 14 15 w 26 27 28 29 30 
Figure 4.05 Attendant Console Keypad and Feature Button Depression Sequence 
4-37  

Page 350

SATURN IIE EPABX A30808-X5130-DllO-l-8920 
Maintenance and Troubleshooting Issue 1, May 1986 
Table 4.14 Attendant Console Test 
, STEP PROCEDURE VERIFICATION IF tiERtFlcATi0~ 
IS NOT OBTAINED 
1 Place maintenance test phone off-hook. Dial tone is returned. 
2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 
3 Dial 3 to enable the Apparatus Tests. Confirmation tone is returned. 
4 Place maintenance test phone on-hook. None 
5 At the Console under test, dial the At- Recall dial tone is...