Page 331
SATURN IIE EPABX Maintenance and Troubleshooting - A30808-X5130-DllO-l-8920 Issue 1, May 1986 Table 4.05 Allowable Voltage Ranges MODULE/OUTPUT NOMINAL VOLTAGE VOLTAGE RANGE CONNECTOR-PIN LTUPS l + 5Vdc + 4.9 tp + 5.2 Jl-2, -3, -12, -13 (if system is equipped + 12Vdc +11.3 to +12.7 Jl-1, -11 with LTU shelf(s)) -12Vdc -11.3 to -12.7 Jl-5, -15 - 5Vdc - 4.9 to - 5.2 Jl-4, -14 PSU - 5Vdc - 4.9 to - 5.2 JlO-1 + 5Vdc l * * + 4.9 to f 5.2 J9-1, -2, -3, :4; Jll-1, -2; J6-3 + 12Vdc +11.3 to...
Page 332
A30808-X5130-DIIO-l-8920 Issue 1, May 1986 SATURN IIE EPABX Maintenance and Troubleshootrng (b) If the circuit breaker trips off (down) again, switch it on again. (1) If the circuit breaker does not trip to off im- mediately, continue to observe it for a peri- od of time to determine that it remains on. Also, check system for proper performance. (2) If the circuit breaker trips off again, replace the associated power supply as indicated below: BASIC PS circuit breaker: replace the PSU. (If...
Page 333
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1, May 1986 Jg,(I, j-J11w
Page 334
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting issue 1, May 1986 I J2/P2 Pin 1 -48Vdc (-488) 2 Ground 3 -48Vdc (-48P) 4 Ground Jl/Pl Junction LINE-AC IN LINE AC IN Pin Box (AC%@ IN) (AC#l IN) 1 AC Line Note 2 2 AC Neutral 3 AC Ground -48PSo Note 1 PSU J2 Notes: 1. When -48PSl is installed, voltages on connectors Jl and J2 are the same as those on -48PSfi. 2. Second AC input is required only when expansion cabinet is used and -48$PSl is installed....
Page 335
SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-6920 Issue 1, May 1986 (3) If the voltages return to normal after remov- ing all the PCBs, a PCB has probably short- ed. Reinsert the PCBs in the shelf, one at a time, and recheck the the PSU output vol- tages at the Basic Shelf after each PCB is inserted. If the low voltage readings return after inserting a PCB, the PCB is defective. Replace the PCB. (c) If all output voltages from the PSU are zero and ac is applied to the...
Page 336
A30808-X5130-DllO-l-8920 Issue 1, May 1986 El +5Vdc J46IP46 Pin 1 RAC/RMW 2 Ground 3 -48Vdc (-48P) J47IP47 Pin 1 -5Vdc 2 -48Vdc (-488) 3 Ground 4 Ground E2 + 5Vdc J48lP48 Pin 1 -12Vdc - 2 +12Vdc 3 +12Vdc 4 Ground 5 +5Vdc (a5B) ’ E3 -i- 5Vdc ’ E4 +5Vdc Figure 4.02 Basic Shelf Backplane Power Connections
Page 337
I SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-l-8920 Issue 1, May 1986 Raceway PI Pin 1 AC Line 2 AC Corn1 3 GND nor Jl Pin Pin Pin 1 +12v 6 RET 11 +12v 2 +5v 7 RET 12 +5v 3 +5v 8 Keying Plug 13 +5V 4 -5v 9 RET 14 -5v 5 -12V 10 RET 15 -12v Figure 4.03 LTUPS Module Power Connections 4-25
Page 338
SATURN IIE EPABX Maintenance and Trouhleshootlng J42 Pin 1 -k5v 2 RING S GND 4 -48P 5 -5v J43 Pin 1 GND 2 -488 3 +5v 4 +12v 5 -12v ’ J44 Pin 1 GND 2 +5v 3 +5v 4 GND AC (+-5Vdc) (RAC/RMV (Ground) (Ground) (-48Vdc) (+SVdc) (Ground) V) ! Figure 4.04 LTU Shelf Backplane Power Connections 4-16
Page 339
I _-. SATURN IIE EPABX Maintenance and Troubleshooting 4.07 Single-Line Telephone Related Failures. Step-by-step instructions for troubleshooting the single-line telephone (SLT) (i.e., 500-or 2500-type analog instrument) are provided below: a. If the SLT is completely inoperative (i.e., no talk battery), 1. Using the SERVICE CMU Procedure, check serv- ice state of the circuit serving this SLT (a) If in-service, continue with step 2. (b) If out-of-service-craft, return the circuit to the...
Page 340
SATURN IIE EPABX Maintenance and Troubleshooting I ’ A30808-X5130-DllO-l-8920 Issue 1, May 1986 in-service state (Table 4-lo), and verify opera- tion. Continue with step 2 if the SLT remains inoperative. (c) If out-of-service - automatic, attempt to return the circuit to the in-service state (Table 4-10). (1) If circuit returns to the in-service state and the failure clears, the problem was tran- sient. If transient problems recur on the same circuit, continue with step 2. (2) If the...