SATURN IlE EPABX Maintenance and Troubleshooting SEC?‘lON 1.00 INTRODUCTION 1.01 Purpose. This maintenance series practice provides step-by-step instructions for troubleshooting and repairing a malfunctioning SATURN IIE (SATURN II - Expanded) Elec- tronic Private Automatic Branch Exchange (EPABX) System. The information contained in this practice allows maintenance personnel to locate and correct malfunctions during precutover and postcutover of the system. Figures 1.00 and 1.01 illustrate the...
Page 282
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting issue 1, May 1986 Figure 1.00 SATURN IIE System Basic Cabinet 1-2
Page 283
- A3~~0~-~513O-~i~o-~-8~~~ issue I, May 19% SATURN IIE EPABX Maintenance and Troubleshooting IN Ii E SIEMENS Q
Page 284
SATURN IiE EPABX Maintenance and Troubleshooting Table 1.00 Mnemonics Used in This Practice MNEMONIC DEFINITION AC6 Automatic Call Distribution ANA Assigned Night Answer ASCII American Standard Code for Information Interchange CE Common Equipment CIOP Controller/Input-Output Processor CMU Customer Memory Update co Central Office CONF Conference CRC Cyclic Redundancy Check CRT Cathode Ray Tube DCI Data Communications Interface DID Direct Inward Dialing DIP Dual lnline Package DISA Direct...
Page 285
I - SATURN IIE EPABX Maintenance and Troubleshooting Table 1.00 Mnemonics Used in This Practice (Continued) A30808-X5130-DllO-l-8920 Issue 1, May 1986 MNEMONIC I DEFINITION SLMA-S SLMD SLT SMDR SMXTG T&R TM BA-2 TMBA-4 TMBM TMIE TMS TTY -48PS Subscriber Line Module Analog - Station Subscriber Line Module Digital Single-Line Telephone Station Message Detail Recording Signal Multiplexer/Tone Generator Tip and Ring 2-Wire E&M Trunk 4-Wire E&M Trunk Central Office Trunk Direct...
Page 286
I - SATURN IIE EPABX Maintenance and Troubleshooting SECTION 2.00 MAINTENANCE OVERVIEW A30808-X5130-DllO-l-6920 Issue 1, May 1986 2.01 Introduction. This section describes the design con- siderations and maintenance facilities incorporated in the SATURN IIE EPABX. The maintenance concept for the EPABX is based on detecting and isolating failures to the Least Replaceable Unit (LRU), replacing the faulty LRU, and restor- ing normal service as soon as possible. The maintenance con- cept does...
Page 287
SATURN IIE EPABX Maintenance and Troubleshooting A30808-X5130-DllO-I-8920 Issue 1, May 1986 2.03 Design Considerations. The design considerations in- corporated in the SATURN IIE EPABX are discussed below. a. Component Packaging. The SATURN IIE EPABX ar- chitecture is modularly designed to allow maintenance personnel to quickly recognize and isolate failures. Modularity is achieved primarily by using Large Scale Integration (LSI) and Medium Scale Integration (MSI) techniques. Extensive use of...
Page 288
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting Issue 1. May 1986 Fuses I Battery Test On Battery Power Battery Test LED (Red) +5V Adjust LED (Gr7en) Switch I Potentl]ometer Major LED Minor LED Active LED MTCE Phone (Red) Jack (Yellow) Switch Figure 2.01 Power System Unit, (PSU) Front View 2-3
Page 289
A30808-X5130-DllO-l-8920 Issue 1, May 1986 SATURN IIE EPABX Maintenance and Troubleshootrng 2.06 Maintenance Phone. The maintenance phone can be either a portable test phone, test set, or a standard two-wire station instrument used to access the maintenance functions of the system, either locally or remotely. a. Local Maintenance Functions. The maintenance line is usually assigned as a Dual-Tone Multifrequency (DTMF) station type; however, a Dial Pulse (DP) or DTMF maintenance phone may be...
Page 290
SATURN IIE EPABX A30808-X5130-DllO-l-8920 Maintenance and Troubleshooting issue 1, May 1986 I Figure 2.02 Controller/Input-Output Processor Printed Circuit Board (CIOP) 2-5