SATURN IIE EPABX 
Installation Test Procedures A30808-X5130-B120-l-8928 
issue 1, May 1986 
W23 EXPANSION CABINET 
 
I 
--- --- 
: ] 1 
FDD : 
, i;wi! 
i-L--i-- - _-__ 
-- 
LiTJ-. - - 
-r----- * 
W22 
BASIC CA&NET 
A5040-2.313186 
Figure 2.01 Signal Cable Distribution for the SATURN IIE System (Expansion Cabinet) 
2-5  

Page 232

SATURN IIE EPABX 
tnstallation Test Procedures A30808-X5130-8120-1-8928 
Issue 1, May 1986 
LTUSO 
LINE TRUNK UNIT SHELF J42 
J43 r JP 
L 
Jl 
BASS 
BASIC SHELF El a---- 
J46 
J47 
E2 
05039.1..wmG 
Figure 2.02 Power/Ground Distribution for the SATURN IIE System (Basic Cabinet) 
2-6  

Page 233

A30808-X5130-B120-l-8920 
Issue 1, May 1986 
EXPANSION CABINET REF. 
L --M--e-- ---- -,-, 
------ 
----- 
BASIC‘CABINET REF. 
A5U38-1-4:3:86 Figure 2.03 Power/Ground Distribution for the SATURN IIE System (Expansion Cabinet) 
2-7 (2-8 blank)  

Page 234

SATURN IIE EPABX A30808-X5130-B120-l-8928 
Installation Test Procedures 
issue 1. May 1986 
3.01 General. The SATURN HE System must be connected 
to an earth ground (i.e., metallic cold water pipe or master ground 
busbar) in addition to the safety ground in the ac power cord. 
A G-gauge (twisted copper wire) conductor should be connect- 
ed between the grounding lug E5 located on the bottom of the 
cabinet frame and the snlccted earth ground (refer to Section 
3.00 in the SATURN HE EPABX Installation...

Page 235

SATURN IIE EPABX A30808-X5130-B120-l-8928 
Installation Test Procedures Issue 1, May 1986 
BASIC Cabinet 
GND 
LUG Fuse Box Facility 
(ES) , 
5, B D Power co 
PSU 
f llOVAC~$GOi-fZ 
El El Neulral 
Ground 
hlatn Cabmel 
(Rear View) 
Recommended: B-gauge 
(iwtsted Copper Wire) 
conductor not exceedmg 
i26 feet m length. 
I (Ootlonall 
I.1 
f Master Ground Busbar 
Earth Ground Note: Single Point Ground (SPG) configuration IS shown 
Figure 3.00 System Ground Test Connections 
3-2  

Page 236

SATURN IIE EPABX 
Installation Test Procedures A30808-X5130-8120-1-8928 
Issue 1, May 1986 
Busbar/ 
Backplane 
- 
Attaching 
Screws 
GND 
Lug 
No. E5 ’ 
7 
- 
Recommended: 6 Guage 
(twisted copper wire) conductor 
not exceeding 126 feet in length. I(Rear View) Busbar Grounded at 
Fuse Box Facility 
 I 
L 
---_ -I 
Power 
Cord Plug 
7 Master Ground Busbar 
Earth Ground 
Note: Single Point Ground (SPG) configuration is shown 
Figure 3.01 Shelf Ground Continuity Test Connections 
3-3 (3-4 blank)  

Page 237

I 
-_ 
SATURN IIE EPABX 
installation Test Procedures A30808-X5130-BlZO-l-8928 
Issue 1, May 1986 
SECTION 4.00 POWER-UP TESTS 
4.01 General. The SATURN IIE System makes use of dis- 
tributed power in the equipment cabinet. Several power sup- 
plies are used in the system. These power supplies provide 
+5Vdc, -SVdc, +12Vdc, -12Vdc, -48Vdc, 90Vac-20Hz ringing 
voltage and message waiting voltage, from a 11OVac 60Hz 
input power source. After satisfactorily performing the ground 
tests indicaied in Section...

Page 238

SATURN IlE EPABX 
Installation Test Procedures A30808-X5130-8120-1-8928 
issue 1, May 1986 
Table 4.00 Power-Up/Output Voltage 
Test (Continued) 
SE? 
PROCEDURE VEfiIFICATION IF VERIFICATION 
IS NOT OBTAINED 
c) On the PSU, place the circuit The red LED designated BATTERY If the red LED remains extinguished, 
breaker designated BASIC PS TEST.should be steadily lit. replace the MSM. 
in the off (down) position. 
The red BATTERY TEST LED should 
1 d) On the PSU, place the circuit If the red LED remains...

Page 239

I 
- 
SATURN IIE EPABX 
Installation Test Procedures A3G808-X5130-B120-1-B928 
Issue 1, May 1986 
lbb!c 4.00 Power-Up/Output Voltage Test (Continued) 
STEP FROCEDUEE VERIFICATION IF VERIFICATION 
IS NOT OBTAINED . 
f) Connect positive lead of digital Voltage measured should read + If reading is not 0.05 Vdc, adjust +5V 
multimeter to pin 5 of connec- 0.05Vdc. ADJUST potentiometer on PSU. If 
tor J48 and negative lead to adjustment is not effective, replace 
terminal El on basic back- PSU. 
plane. (Refer...

Page 240

SATURN IIE EPABX 
Installation Test Procedures A30808-X5130-B120-l-6928 
Issue 1, May 1986 
Table 4.00 Power-Up/Output Voliagc? Test (Continued) 
STEP PROCEDURE VEFllFlCATlON IF VERIFICATION 
IS NOT OBTAINED 
1) Pins 1 and 3. Voltage measured should read be- If reading is not within tolerance, ad- 
tween +4.5 and +5.5Vdc. just +5V ADJUST potentiometer on 
LTUPSO. If adjustment does not bring 
the voltage into tolerance, replace 
LTUPSO. 
2) Pins 1 and 2. Voltage measured should read be- If reading is not...