Page 201
SATURN IIE EPABX Installation Procedures A30808-X5130-8110-1-6928 issue 1. May 1986 PWiUW3ZTiE6 Figure 4.43 CIOP PCB 4-72
Page 202
SATURN IIE EPABX Installation Procedures A30808-X5130-6110-1-8928 Issue 1. May 1986 Table 4.29 Memory 1.0 Megabyte (MEM4) PCB (S30819-Ql775-X-*-8900) DESCRIPTION: The MEM4 PCB, shown in Figure 4.44, provide 1.0 megabyte of dynamic Random Access Memory (RAM) and its supporting logic to store system data. The memory is organized as 512K words X 16 bits/word, and divided into 64K byte pages. Memory write protection is provided in 1K word segments. MEM4 is arranged for battery backup memory protection...
Page 203
I - SATURN IIE EPABX installation Procedures A30808-X5130-BllO-l-B928 Issue 1. May 1986 P5m143120186 Figure 4.44 MEM4 PCB 4-74
Page 204
SATURN IIE EPABX A30808-X5130-BllO-l-8928 installation Procedures Issue 1, May 1986 Table 4.30 Memory 256 Kilobyte (MEM3) PCB (S30810-Q174O-X-e-8900) DESCRIPTION: . . The MEM3 PCB, shown in Figure 4.45, provide 256 kilobytes of dynamic Random Access Memory (RAM) and its supporting logic to store system data. The memory is organized as 128K words X 16 bits/ word, with memory write protection provided in 1K word segments. MEMB is arranged for battery backup memory protection to safeguard stored data...
Page 205
SATURN IIE EPABX A30808-X5130-BllO-l-8928 Installation Procedures Issue 1, May 1986 P5uiuW320166 Figure 4.45 MEM3 PCB 4-76
Page 206
I - SATURN IIE EPAEX A30808-X5130-8110-l-8928 Installation Procedures Issue 1, May 1986 Table 4.31 Line/lhmk Unit Control (LTUC) PCB (S30810-Q428-X- * -8900) DESCRIPTION: The LTUC PCB. shown in Figure 4.46, provides the tim.ing signals necessary to address a line/trunk unit. It multiplexes and demultiplexes both signal and voice highways. It also provides fault monitoring and reporting of failures associated with the 128.ports it handles. 1. Indicators. Three red LEDs, designated PRS, ALMO, and...
Page 207
SATURN IIE EPABX Installation Procedures A30808X5130-8110-1-8928 Issue 1, May 1986 Red LEDs Figure 4.46 LTUC PCB 4-78
Page 208
I - SATURN IIE EPABX Installation Procedures A30808-X5130-BllO-l-8928 Issue 1, May 1986 4.08 Attendant Console. The attendant console is used handling special system functions such as paging, message primarily to answer external calls (i.e., incoming trunk calls) and waiting and conference calling. A maximum of 12 attendant con- extend such calls to the appropriate internal stations. The con- soles can be interfaced with a particular system. Refer to Table sole may also be used to assist in...
Page 209
SATURN IIE EPABX Installation Procedures A30808-X5130-BllO-l-8928 issue 1, May 1986 Standard Modular Jack Duolex B-Contact 1 1 Modular Jack Termmation in the rear - bottom of Console internal Circuilry Designaflons I , / L TRRTL F XXXXF I MDF Assignments Via House Cabling -2 2 1 1 -1212+ I Modular Lme Cord bms?-%a386 Figure 4.47 Attendant Console Connections 4-80 (80 pages)
Page 210
- I - SATURN HE EPABX A30808-X5130-BllO-l-6928 Installation Procedures Issue 1, May 1988 SECTION 5.00 SYSTEM SIGNAL AND POWER/GROUND CABLING ARRANGEMENTS 5.01 General. This section provides the signal and pow- er/ground-cabling arrangements for the SATURN IIE System. Tables 5.00 and 5.01 list all the cable reference numbers used throughout this practice. The tables provide point-to-point ca- ble terminations and refer users to the appropriate cabling illustration for quick reference. The...