Table 4.14 Premium Instrument Module Digital (PIMD) PCB (S30810-Q432-X- * -8900) 
DESCRIPTION: The PIMD PCB serves as a special line interface circuit connecting attendant consoles to the system. 
The PIMD communicates with the system via digital data messages. Each PIMD PCB, shown in Figure 
4.28, contains two circuits. 
1. Indicators. None. 
2. Switches. None. 
3 Strapping Options. None. 
OBSERVATIONS: None. 
INSTALiATdN 
PROCEDURES: Locate in any...

Page 172

I 
- 
SATURN IIE EPABX 
Installation Procedures A30808-X5130-BllO-l-8928 
Issue 1. May 1986 
. 
Figure 4.28 PIMD PCB 
4-43  

Page 173

SATURN HE EPABX A3O808-X5130-f3110-1-B928 
Installation Procedures Issue 1, May 1986 
I Table 4.15 Subscriber Line Module Analog - Station (SLMA-S) PCB (S30810-Q1674-X- * -B900) 
I 
DESCRIPTION: 
OBSERVATIONS: 
INSTALLATION 
PROCEDURES: The SLMA-S PCB provides an interface between standard telephone sets (rotary dial and pushbutton) 
and the system. The SLMA-S PCB, shown in Figure 4.29 , contains eight circuits (0 - 7) and utilizes 
eight ports. Each circuit provides the required supervisory signaling...

Page 174

SATURN IIE EPABX 
Installation Procedures A30808-X5130-BllO-l-8928 
Issue 1, May 1986 
, 
Gieen LED 
Figure 4.29 SLMA-S PCB 
4-45  

Page 175

I 
- 
A30808-X5130-8110-l-8928 
Issue 1, May 1986 
Table 4.16 Subscriber Line Module Analog - Off-Premises (SLMA-0) PCB (S30810-Ql7’39-X- * -B900) 
DESCRIPTION: 
. . 
*’ The SLMA-C PCB provides an interface between standard telephone sets (rotary dial and pushbutton) 
which are Off-Premises and the system. The SLMA-CI PCB, shown in Figure 4.30 , contains four circuits 
(0, 2, 4, 6) and utilizes four ports. Each circuit provides the required supervisory signaling plus the analog 
toPCM and PCM-to-analog...

Page 176

SATURN HE EPABX 
installation Procedures A30808-X5130-8110-l-8928 
Issue 1, May 1986 
I 
Figure 4.30 SLMA-0 PCB 
4-47 
I 
-  

Page 177

I 
- 
SATURN HE EPABX 
installation Procedures A30808-X5130-Bllo-l-8928 
Issue 1, May 1986 
Table 4.17 Subscriber Line Module Digital (SLMD) PCB (S30810-Q1724-X-*-8900) 
DESCRIPTION: The SLMD PCB provides an interface between standard Siemens digital telephone (SDT) sets and the 
system. The SLMD PCB, shown in Figure 4.31 , contains eight circuits (O-7) and utilizes eight ports. 
1. Indicators. One red LED which indicates the following status conditions: 
a. LED lit steadily - One or more of the line...

Page 178

I 
- 
SATURN IIE EPABX 
Installation Procedures A30808-X5130-BllO-l-8928 
issue 1, May 1986 
Figure 4.31 SLMD PCB 
4-49  

Page 179

SATURN IIE EPABX 
Installation Procedures Issue 1, May 1986 
Table 4.18 Subscriber Line Analog - 18 Line(SLA16) PCB (S30810-Q1790X * -8900) 
DESCRIPTION: The SlAl6 PCB, shown in Figure 4.32, provides sixteen interfacing circuits (O-7 for upper half and O-7 
in virtual slot for lower half) between rotary dial and/or DTMF stations and the system. 
1. Indicators. One green LED which indicates the following status conditions: 
a. LED lit steadily - One or more of the line circuits are busy. 
b. LED...

Page 180

- 
SATURN HE EPABX 
Installation Procedures A30808-X5130-BllO-l-8928 
Issue 1, May 1986 
.’ 
P557&22.920186 Figure 4.32 SLA16 PCB 