Page 121

I 
- 
SATURN IIE EPABX 
A30808-X5130-BllO-l-8928 
Installation Procedures 
Issue 1, May 1986 
ASSEMBLY 
SLOTNO. 0 1 2 3 4 5 6 7 10  6 9 11 12 13 14 15 16 17 16 19 20 21 22 23 24 25 
CHANNEL -CH GP--, CH GP 
GROUP 0 
l 2 -CH GP-, CH GP ,-CH GP-, CH GP 1 2 3 4 5 CJ ( -cH6Gp- cH7Gp 
SLOT NO. O(21416 012 5 0121416 012 012 4 6 012 g 01214[6 012 
Figure 2.10 LTU Shelf Channel and Slot Number 
2-16 (16 pages)  

Page 122

I 
SATURN IIE EPABX A30808-X5130-8110-l-8928 
Installation Procedures Issue 1, May 1986 
SECTION 3.00 CUSTOMER SITE PREPARATION 
3.01 General. This section specifies the equipment room 
preparation and house cabling procedures used to install a 
SATURN IIE System. Included is a recommended MDF lay- 
out for the system. 
3.02 Equipment Room Preparation. The SATURN IIE Sys- 
tem may be located in a dedicated room. This room, desig- 
nated “equipment room” in this practice, must meet the 
environmental...

Page 123

‘I 
SATURN IIE EPABX A30808-X5130-8110-l-8928 
Installation Procedures Issue 1, May 1986 
feet on all sides of the SATURN IIE System cabinet. 
A connection must be made between the metal fila- 
ments and earth ground. This ground connection 
must not be the SATURN HE System ground. 
b. Cabinet Space and Floor Loading Specifications. The 
following specifications are presented to aid craft per- 
sonnel in selecting an adequate equipment room for 
the SATURN IIE System: 
1. Cabinet Space Specifications....

Page 124

. I 
SATURN IIE EPABX 
Installation Procedures A30808-X5130-8110-l-8928 
Issue 1, May 1986 
  42 Inches 
(I07 CM) 
__r 
44 Inches 
(111.7 CM) 
I 
1- 
Figure 3.01 Basic Cabinet Physical Dimensions (Rear View) 
Table 3.01 Basic and Exoanslon Cabinets AC lnout Power Reouirements 
I I NORMAL 
I BROWNOUT 8 EMERGENCY 
NOMINAL 
VOLTAGE FREQUENCY VOLTAGE FREQUENCY 
INPUT 
0-z) (Hz) 
MIN MAX MIN MAX 
IlO-Vat 100 127 
60 f 0.1 95 130 6Ok3.0 
3-3  

Page 125

I 
- 
SATURN IIE EPABX 
Installation Procedures A30808-X5130-6110-1-8928 
Issue 1, May 1986 
986.1.‘lWt)6 Figure 3.02 Basic and Expansion Cabinets Physical Dimensions  

Page 126

SATURN IIE EPABX 
Installation Procedures A30808-X5130-BllO-1-8928 
Issue 1, May 1986 
c. Cabinet Input Power and Grounding Requirements. 
The following information is presented to aid craft per- 
sonnel in selecting an adequate AC power source, as 
well as a ground source, for powering a SATURN IIE 
System cabinet. 
t. AC Input Power Requirements. One AC input source 
is required for the basic cabinet. A second AC in- 
put source is required when the expansion cabinet 
is added, as shown in Figure 3.03....

Page 127

SATURN IIE EPABX A30808-X5130-BllO-l-6928 
Installation Procedures Issue 1, May 1986 
Fuse Box Faci 
Fuse Box Facili 
A second AC power cord is required if 
an Expansion Cabinet is included. also 
Figure 3.03 SATURN IIE System Main Power/Ground Connections 
3-6  

Page 128

SATURN IIE EPABX A30808-X5130-BllO-l-6928 
Installation Procedures Issue 1, May 1986 
Table 3.02 Ground Conductor Length vs. Wire Gauge 
GAUGE 
6’ 4 
2 
1 
0 
00 
FEET 
126 
201 
320 
404 
509 
642 
METERS 
38 61 
98 
123 
155 
196 
(’ = Recommended first choice) 
I- T/R Leads - - E/M 
!i 
s L 
I T 
Leads - 
1 
I 
I J 
I 4 
I ’ 
Note: If E/M signaling or 
SLA16 PCBs are not 
used in the EPA% 
MDF cables J27, 
J29, J31, J33, J35, 
J37, J39, J41, J43 
and J45 are not re- 
quired. 
Figure 3.04 Suggested MDF...

Page 129

SATURN IIE EPABX 
Installation Procedures 
b. SATURN IIE Console, SDT Cabling Requirements. dard telephone cable (i.e.; quad cable or non-twisted 
When such SATURN ancillary equipment is to be in- cable). Quad cable may be used, but its usage is 
stalled, the following requirements must be observed: limited by the cable length limits listed in Table 3.03. 
1. Required House Cabling. The house cabling be- 
tween the SATURN IIE System and SATURN An- 
cillary Equipment can be any cable length up to and...

Page 130

SATURN IIE EPABX A30808-X5130-8110-l-8928 
installation Procedures Issue 1, May 1986 
SECTION 4.00 EQUIPMENT INSTALLATldN PROCEDURES 
4.01 General. The SATURN IIE System is shipped in kits 
and as individual items according to customer requirements. 
This section contains the necessary information to install the 
various equipment kits and items listed in Table 4.00. 
Table 4.00 SATURN IIE EPABX Orderable Items List 
AVAILABLE EQUIPMENT, PART NO. COMMENTS 
Basic-Cabinet (1lOVac 60Hz) L30808-X5130-Al- *...