Home > Ricoh > All in One Printer > Ricoh Mp C3000 Service Manual

Ricoh Mp C3000 Service Manual

Here you can view all the pages of manual Ricoh Mp C3000 Service Manual. The Ricoh manuals for All in One Printer are available online for free. You can easily download all the documents as PDF.

Page 361

 
SM 4-99 B230/B237/D042 
Trouble 
shooting 
  

Page 362

B230/B237/D042 4-100 SM 
(From the previous diagram) 
4.5.2 LINE POSITION ADJUSTMENT 
When there are color registration errors on the output, do the line position adjustment as 
follows. 
 
ƒ  Use A3/DLT size paper for this adjustment. 
Test 
1.  Do SP2-111-003 (Mode c: rough adjustment). 
2.  Use SP2-194-007 to check if the result  of the line position adjustment is correct 
(0: Completed successfully, 1: Not completed). If the result is 1, refer to 
‘Countermeasure list for color registration errors’....

Page 363

 
SM 4-101 B230/B237/D042 
Trouble 
shooting 
 
After Executing SP2-111-003 
Result (SP2-194)  
-007 -010, -011, 
-012  Test pattern check
 Possible cause/Countermeasure  
White image, 
Abnormal image, Low 
density 
ƒ Defective laser optics housing unit 
shutter 
ƒ Defective image processing unit 
ƒ Low density of test pattern 
ƒ Defective BICU 
1.  Replace the shutter motor. 
2.  Replace the high voltage power  supply unit. 
3.  Do the forced process control  (SP3-011-001) or supply some 
toner...

Page 364

B230/B237/D042 4-102 SM 
 
    The sub scan 
registrations of M, C, 
Y are shifted by more 
than ± 20 mm from 
the sub scan 
registration of Bk. 
ƒ Defective image transfer belt 
ƒ Defective drive units 
ƒ Defective BICU 
1.  Replace the image transfer belt. 
2.  Replace the drum motor. 
3. Replace the BICU.  

Page 365

 
SM 4-103 B230/B237/D042 
Trouble 
shooting 
 
The main scan 
registration is shifted 
by more than ± 0.66 
mm, but only at the 
central area of the 
image on the output. 
ƒ Defective ID sensor at center 
ƒ Deformed center area on the image 
transfer belt   
ƒ Defective BICU 
1.  Replace the ID sensor. 
2.  Replace the image transfer belt. 
3. Replace the BICU. 
The skew for M, C, Y 
is more than ± 0.75 
mm from the main 
scan registration of 
Bk  
ƒ  Defective PCU 
ƒ Defective laser optics housing unit...

Page 366

B230/B237/D042 4-104 SM 
 
After Executing SP2-111-001 
Result (SP2-194) 
-007 -010, -011, 
-012  Test pattern check
 Possible cause/Countermeasure  
White image, 
Abnormal image,   
Low density 
ƒ Defective laser optics housing unit 
shutter 
ƒ Defective image processing unit 
ƒ Low density of test pattern 
ƒ Defective BICU 
1.  Replace the shutter motor. 
2.  Replace the high voltage power  supply unit. 
3.  Do the forced process control  (SP3-011-001) or supply some 
toner (SP3-015-xxx).   
4. Replace...

Page 367

 
SM 4-105 B230/B237/D042 
Trouble 
shooting 
 
The main scan 
registrations of M, C, 
Y are shifted by more 
than ± 1.4 mm from 
the main scan 
registration of Bk. 
ƒ No defective component 
ƒ Defective laser optics housing unit
ƒ Defective BICU 
1.  Do SP2-111-003 again. 
2.  Replace the laser optics housing  unit. 
3. Replace the BICU. 
The sub scan 
registrations of M, C, 
Y are shifted by more 
than ± 1.4 mm from 
the sub scan 
registration of Bk. 
ƒ  No defective component 
ƒ Defective image...

Page 368

B230/B237/D042 4-106 SM 
(see the note at the bottom of the 
table). 
2. Replace the BICU. 
 
The main scan 
registration of Bk is 
shifted. ƒ  Abnormal SP setting value of 
main scan: Bk 
1.  Adjust the value with  SP2-101-001.  
No color 
registration 
errors  The main scan 
length of Bk is 
shifted. 
ƒ Abnormal SP setting value of 
main scan length detection: Bk 
1.  Adjust the value with  SP2-185-001. 
Low image density 
on the output 
ƒ Low pattern density 
1.  Do the forced process control...

Page 369

 
SM 4-107 B230/B237/D042 
Trouble 
shooting 
 
The main scan 
registrations of M, C, 
Y are shifted. 
ƒ Defective laser optics housing unit
ƒ Defective ID sensor 
ƒ Defective BICU 
ƒ Incorrect SP value 
1.  Replace the laser optics housing  unit. 
2.  Replace the ID sensor. 
3. Replace the BICU. 
4.  Adjust the value with  SP2-182-004 to -021. 
 
The sub scan 
registrations of M, C, 
Y are shifted. 
ƒ  Defective image transfer belt 
ƒ Defective drive units 
ƒ Defective ID sensor 
ƒ Defective BICU 
ƒ...

Page 370

B230/B237/D042 4-108 SM 
 
 
ƒ  For details about how to reset the skew correction value, s ee Recovery procedure 
for SC285 and no replacement preparation of  laser optics housing unit in “Laser 
Optics Housing Unit Replac ement” (in the Replacement  and Adjustment section  of 
the manual).  
Start reading Ricoh Mp C3000 Service Manual

Related Manuals for Ricoh Mp C3000 Service Manual

All Ricoh manuals