Page 401
SM 5-13 B230/B237/D042 Service Tables 054 Thick 2: FC: Simplex *ENG [120 to 180 / 175 / 1°C/step] 055 Thick 2: BW: Simplex *ENG [120 to 180 / 175 / 1°C/step] 056 OHP: FC *ENG [120 to 180 / 175 / 1°C/step] 057 OHP: BW *ENG [120 to 180 / 165 / 1°C/step] 058 Special 1: FC: Simplex *ENG [120 to 200 / 165 / 1°C/step] 060 Special 1: FC: Duplex *ENG [120 to 200 / 165 / 1°C/step] 062 Special 1: BW: Simplex *ENG [120 to 200 / 165 / 1°C/step] 064 Special 1: BW: Duplex *ENG [120...
Page 402
B230/B237/D042 5-14 SM [0 to 30 / 10 / 1 °C/step] 089 Thick 3: FC: Simplex *ENG [120 to 180 / 180 / 1°C/step] 091 Thick 3: BW: Simplex *ENG [120 to 180 / 170 / 1°C/step] 109 Middle Thick: FC: Simplex *ENG [120 to 180 / 170 / 1°C/step] 110 Middle Thick: FC: Duplex *ENG [120 to 180 / 170 / 1°C/step] 111 Middle Thick: BW: Simplex *ENG [120 to 180 / 170 / 1°C/step] 112 Middle Thick: BW: Duplex *ENG [120 to 180 / 170 / 1°C/step] [Fusing Temperature Display] Fusing...
Page 403
SM 5-15 B230/B237/D042 Service Tables Stop Time * ENG [5 to 30 / 10 / 1 sec/step] 003 Specifies the time fo r measuring the nip. 111 2 [Environmental Correction: Fusing] Temp.: Threshold: Low *ENG [10 to 23 / 17 / 1 °C/step] 001 Specifies the threshold temperatur e for low temperature condition. Temp.: Threshold: High *ENG [24 to 40 / 30 / 1 °C/step] 002 Specifies the threshold temperature for high temperature condition. Low Temp. Correction *ENG [0 to 15 / 5 / 1 °C/step] 003...
Page 404
B230/B237/D042 5-16 SM after the machine has recovered from the energy save mode, it returns to the stand-by mode. 111 4 [First Print Correction] Correction Temp. *ENG [0 to 30 / 10 / 1 °C/step] 001 Specifies the additional temperat ure for the first print job. This temperature is added to the heati ng roller for the time specified with SP1114-002. Operation Time *ENG [0 to 60 / 2 / 1 sec/step] 002 Specifies the time for adding the first print additional temperature, which is...
Page 405
SM 5-17 B230/B237/D042 Service Tables 003 Idling Speed *ENG [0 to 3 / 1 / 1 mm/sec /step] Not used 111 6 [Ends Temp. Correction] Center Temp. 1: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 010 Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-018. Ends Temp. 1: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 011 Specifies the temperature correction for the heating roller (ends) when...
Page 406
B230/B237/D042 5-18 SM Specifies the temperature correction for the heating roller (center) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-021. Ends Temp. 4: –226 *ENG [–30 to 0 / –10 / 1°C/step] 017 Specifies the temperature correction for the heating roller (ends) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-021. Control Time 1: 226– *ENG [0 to 250 / 0 / 1 sec/step] 018 Specifies the...
Page 407
SM 5-19 B230/B237/D042 Service Tables Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-026. Ends Temp. 1 Duplex: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 023 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-026. Center Temp. 2 Duplex:...
Page 408
B230/B237/D042 5-20 SM 111 7 [Idling Time After Heater OFF] After Ready *ENG [0 to10 / 4 / 1 sec/step] DFU 001 Specifies the idling time without t he lamp on after reaching the ready temperature. After Job End *ENG [0 to10 / 4 / 1 sec/step] 002 Specifies the idling time without the lamp on after job end. This idling prevents the heating roller overheating after job end. 11 5 9 [Fusing Jam Detection] SC Display *ENG[0 or 1 / 0 / 1 /step] 0: Disable, 1: Enable 001 Enables...
Page 409
SM 5-21 B230/B237/D042 Service Tables 010 MCY Development: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 011 MCY Development: 138 *ENG [–4 to 4 / 0 / 0.01 %/step] 012 MCY Development: 77 *ENG [–4 to 4 / 0 / 0.01 %/step] 013 Fusing: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 014 Fusing: 138 *ENG 015 Fusing: 77 *ENG[–4 to 4 / 0.4 / 0.01 %/step] 016 Image Transfer: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 017 Image Transfer: 138 *ENG [–4 to 4 / 0.3 / 0.01 %/step] 018...
Page 410
B230/B237/D042 5-22 SM Counterclockwise 1907 [Paper Feed Timing Adj.] DFU 003 Feed Clutch OFF: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 004 Feed Clutch ON: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 005 Inverter Stop Position *ENG [–10 to 10 / 0 / 1 mm/step] 006 Exit Stop Position: 3rd Sheet *ENG [–10 to 10 / 0 / 1 mm/step] 011 Entrance Stop Position *ENG [–7 to 10 / 0 / 1 mm/step] 013 Feed Clutch OFF: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 014 Feed Clutch ON: Thick *ENG [–10 to...