Page 401

 
SM 5-13 B230/B237/D042 
Service 
Tables 
054  Thick 2: FC: Simplex  *ENG  [120 to 180 / 175 / 1°C/step] 
055  Thick 2: BW: Simplex  *ENG 
[120 to 180 / 175 / 1°C/step] 
056 OHP: FC  *ENG 
[120 to 180 /  175 / 1°C/step] 
057 OHP: BW  *ENG 
[120 to 180 /  165 / 1°C/step] 
058  Special 1: FC: Simplex  *ENG 
[120 to 200 / 165 / 1°C/step] 
060  Special 1: FC: Duplex  *ENG 
[120 to 200 / 165 / 1°C/step] 
062  Special 1: BW: Simplex  *ENG 
[120 to 200 / 165 / 1°C/step] 
064  Special 1: BW: Duplex  *ENG 
[120...

Page 402

 
B230/B237/D042 5-14 SM 
[0 to 30 / 10 / 1 °C/step] 
089  Thick 3: FC: Simplex  *ENG 
[120 to 180 / 180 / 1°C/step] 
091  Thick 3: BW: Simplex  *ENG 
[120 to 180 / 170 / 1°C/step] 
109  Middle Thick: FC: 
Simplex  *ENG 
[120 to 180 /  170 / 1°C/step] 
110  Middle Thick: FC: Duplex *ENG 
[120 to 180 / 170 / 1°C/step] 
111   Middle Thick: BW: 
Simplex  *ENG 
[120 to 180 /  170 / 1°C/step] 
112  Middle Thick: BW: 
Duplex  *ENG 
[120 to 180 /  170 / 1°C/step] 
 
[Fusing Temperature Display] Fusing...

Page 403

 
SM 5-15 B230/B237/D042 
Service 
Tables 
Stop Time  * ENG 
[5 to 30 / 10 / 1 sec/step] 
003 
Specifies the time fo r measuring the nip. 
 
111 2   [Environmental Correction: Fusing]  
Temp.: Threshold: Low  *ENG 
[10 to 23 / 17 / 1 °C/step] 
001 
Specifies the threshold temperatur e for low temperature condition. 
Temp.: Threshold: High  *ENG 
[24 to 40 / 30 / 1 °C/step] 
002 
Specifies the threshold temperature for high temperature condition. 
Low Temp. Correction  *ENG  [0 to 15 / 5 / 1 °C/step] 
003...

Page 404

 
B230/B237/D042 5-16 SM 
after the machine has recovered from the energy save mode, it returns to the 
stand-by mode.   
 
111 4   [First Print Correction]  
Correction Temp.  *ENG
[0 to 30 / 10 / 1 °C/step] 
001  Specifies the additional temperat
ure for the first print job. 
This temperature is added to the heati ng roller for the time specified with 
SP1114-002. 
Operation Time  *ENG
[0 to 60 /  2 / 1 sec/step] 
002 
Specifies the time for adding the first print additional temperature, which is...

Page 405

 
SM 5-17 B230/B237/D042 
Service 
Tables 
003 Idling Speed  *ENG
[0 to 3 /  1 / 1 mm/sec /step]  Not used 
 
111 6   [Ends Temp. Correction]  
Center Temp. 1: 226–  *ENG
[–30 to 0 / 0 / 1 °C/step] 
010  Specifies the temperature correction 
for the heating roller (center) when the 
paper width is 226 mm or more.   
The start time of this SP can be adjusted with SP1116-018. 
Ends Temp. 1: 226–  *ENG [–30 to 0 / 0 / 1 °C/step] 
011  Specifies the temperature correction 
for the heating roller (ends) when...

Page 406

 
B230/B237/D042 5-18 SM 
Specifies the temperature correction for the heating roller (center) when the 
paper width is less than 226 mm.   
The start time of this SP can be adjusted with SP1116-021. 
Ends Temp. 4: –226  *ENG [–30 to 0 / –10 / 1°C/step] 
017  Specifies the temperature correction 
for the heating roller (ends) when the 
paper width is less than 226 mm. 
The start time of this SP can be adjusted with SP1116-021. 
Control Time 1: 226–  *ENG [0 to 250 / 0 / 1 sec/step] 
018  Specifies the...

Page 407

 
SM 5-19 B230/B237/D042 
Service 
Tables 
Specifies the temperature correction  for the heating roller (center) when the 
paper width is 226 mm or more in duplex mode. 
The start time of this SP can be adjusted with SP1116-026. 
Ends Temp. 1 Duplex: 
226–  *ENG
[–30 to 0 /  0 / 1 °C/step] 
023 
Specifies the temperature correction  for the heating roller (ends) when the 
paper width is 226 mm or more in duplex mode. 
The start time of this SP can be adjusted with SP1116-026. 
Center Temp. 2 Duplex:...

Page 408

 
B230/B237/D042 5-20 SM 
 
111 7   [Idling Time After Heater OFF]  
After Ready *ENG
[0 to10 /  4 / 1 sec/step]  DFU 
001 
Specifies the idling time without t he lamp on after reaching the ready 
temperature. 
After Job End  *ENG
[0 to10 /  4 / 1 sec/step] 
002 
Specifies the idling time without  the lamp on after job end.   
This idling prevents the heating roller overheating after job end. 
 
11 5 9   [Fusing Jam Detection]  
SC Display  *ENG[0 or 1 / 
0 / 1 /step] 
0: Disable, 1: Enable 
001  Enables...

Page 409

 
SM 5-21 B230/B237/D042 
Service 
Tables 
010  MCY Development: 154  *ENG [–4 to 4 / 0 / 0.01 %/step]  Not used 
011  MCY Development: 138  *ENG
[–4 to 4 / 0 / 0.01 %/step] 
012  MCY Development: 77  *ENG
[–4 to 4 / 0 / 0.01 %/step] 
013 Fusing: 154  *ENG
[–4 to 4 /  0 / 0.01 %/step]  Not used 
014 Fusing: 138  *ENG
015 Fusing: 77  *ENG[–4 to 4 / 
0.4 / 0.01 %/step] 
016 Image Transfer: 154  *ENG
[–4 to 4 / 0 / 0.01 %/step]  Not used 
017 Image Transfer: 138  *ENG
[–4 to 4 / 0.3 / 0.01 %/step] 
018...

Page 410

 
B230/B237/D042 5-22 SM 
Counterclockwise 
 
1907   [Paper Feed Timing Adj.] DFU  
003  Feed Clutch OFF: Plain  *ENG
[–10 to 10 / 0 / 1 mm/step] 
004  Feed Clutch ON: Plain  *ENG
[–10 to 10 / 0 / 1 mm/step] 
005  Inverter Stop Position  *ENG
[–10 to 10 / 0 / 1 mm/step] 
006  Exit Stop Position: 3rd 
Sheet  *ENG
[–10 to 10 /  0 / 1 mm/step] 
011  Entrance Stop Position  *ENG
[–7 to 10 / 0 / 1 mm/step] 
013  Feed Clutch OFF: Thick  *ENG
[–10 to 10 / 0 / 1 mm/step] 
014  Feed Clutch ON: Thick  *ENG
[–10 to...