Page 381
SM 4-119 B230/B237/D042 Trouble shooting 4.7 ELECTRICAL COMPONENT DEFECTS 4.7.1 SENSORS ƒ The CN numbers in the following table ar e the connector numbers on the BICU. No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom Open Open Cover is displayed SW01 Right Cover Open Switch L CN211/35 Shorted Right cover open cannot be detected. S01 ID Sensor A CN213 Open/ Shorted SC400 Open Jam A (Jam8, 17) S02 Registration Sensor L CN212/2 Shorted Jam A, B (Jam1) S03 Drum...
Page 382
B230/B237/D042 4-120 SM No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom Toner End Sensor - K toner. S11 Image Transfer Belt Rotation Sensor H/L CN233/15 Open/ Shorted SC443 Open Jam A (Jam3, 11) S12 Paper Feed Sensor 1 L CN281/2 Shorted Jam A, B (Jam1) Open Paper end is not detected when there is no paper in the paper tray. S13 S16 Paper End Sensor 1, 2 L CN281/5, 14 Shorted Paper end is detected when there is paper in the paper tray. S14 S17 Paper Lift Sensor...
Page 383
SM 4-121 B230/B237/D042 Trouble shooting No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom tray is not detected when paper is set. Detection Sensor Shorted Paper on the by-pass tray is detected when paper is not set. Open Jam C (Jam 18) S24 Fusing Entrance Sensor L CN283/B6 Shorted Jam C (Jam 1) Open Jam Z (Jam 27) S25 Duplex Entrance Sensor L CN283/B9 Shorted Jam Z (Jam 1) Open Jam Z (Jam 25) S26 Duplex Exit Sensor L CN283/B12 Shorted Jam Z (Jam 1) S27 TD...
Page 384
B230/B237/D042 4-122 SM No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom cannot be detected when the waste toner bottle is nearly full. Open Waste toner bottle is not detected when the waste toner bottle is set. SW03 Waste Toner Bottle Set Switch L CN251/A4 Shorted Waste toner bottle is detected when the waste toner bottle is set. S33 Tray 2 Paper Size Switch L CN251/B8, B9, B10, B12 Open/ Shorted Paper size error S34 Temperature/ Humidity Sensor A CN286/1, 3Open/...
Page 385
SM 4-123 B230/B237/D042 Trouble shooting No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom Open Paper overflow message is not displayed when the paper overflow condition still remains. S37 Paper Overflow Sensor L CN218/15 Shorted Paper overflow message is displayed when the paper overflow condition does not remain. S38 Original Width Sensor 1 A CN313/2 Open/ Shorted Original paper size cannot be detected. S39 Original Width Sensor 2 A CN313/5 S40 Original...
Page 386
B230/B237/D042 4-124 SM No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom Contact Sensor Shorted 4.7.2 BLOWN FUSE CONDITIONS Power Supply Unit Rating Fuse 115V 220V - 240V Symptom when turning on the main switch FU1 5A/250V 5A/250V 5VE power to the SIO and IOB not supplied. FU2 5A/250V 5A/250V No response. (5V power to the BICU and controller is not supplied.) FU3 5A/250V 5A/250V 5V power to t he IOB and finisher is not supplied. FU4 10A/125V 10A/125V 24V power to t he...
Page 387
SERVICE TABLES SECTION 5 SERVICE TABLES (SP MODES) REVISION HISTORY Page Date Added/Updated/New 29 03/30/2007 SP 2103 226 ~ 227 07/27/2007 SP modes 275 ~ 276 09/16/2009 SP5985 278 02/19/2009 SP6009-002 283 ~ 285 11/29/2006 SP6136 395 ~ 429 04/07/2009 SP1001 405 03/30/2007 Firmware Update
Page 389
SM 5-1 B230/B237/D042 Service Tables 5. SERVICE TABLES 5.1 SERVICE PROGRAM MODE ƒ Make sure that the data-in LED ( ) is not on before you go in to the SP mode. This LED indicates that some data is coming to the machine. When the LED is on, wait for the copier to process the data. 5.1.1 ENTERING AND EXITING SERVICE PROGRAM MODE ƒ The Service Program Mode is for use by se rvice representatives only. If this mode is used by anyone other than service repr esentatives for any reason, data...
Page 390
B230/B237/D042 5-2 SM SP Mode Button Summary Here is a short summary of the touch-panel buttons. Opens all SP groups and sublevels. Closes all open groups and sublevels and re stores the initial SP mode display. Opens the copy window (copy mode) so y ou can make test copies. Press SP Mode (highlighted) in the copy window to return to the SP mode screen, Enter the SP code directly with the number keys if you know the SP number. Then press . (The required SP Mode number w ill be...