Ricoh Mp C3000 Service Manual
Here you can view all the pages of manual Ricoh Mp C3000 Service Manual. The Ricoh manuals for All in One Printer are available online for free. You can easily download all the documents as PDF.
Page 411
SM 5-23 B230/B237/D042 Service Tables 007 Feed Clutch ON: Thick *ENG [–10 to 10 / 0 / 1 mm/step] SP2-XXX (Drum) 2005 [Charge DC Voltage] Charge Roller DC Voltage Adjustment (Paper Type, Process Speed, Color) Paper Type –> Plain, Thick 1, Thick 2 Adjusts the DC component of the charge ro ller bias in the various print modes. Charge bias (DC component) is automatically adjusted during process control; therefore, adjusting thes e settings does not effect while process control mode...
Page 412
B230/B237/D042 5-24 SM Charge bias (AC component) is adjusted by environment correction (SP2-007-xxx to SP2-011-xxx). Thes e SPs are activated only when SP2-012-1 is set to 1: manual control. 001 Plain: Bk *ENG 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG 005 Thick 1: Bk *ENG 006 Thick 1: M *ENG 007 Thick 1: C *ENG 008 Thick 1: Y *ENG 009 Thick 2&FINE: Bk *ENG 010 Thick 2&FINE: M *ENG 011 Thick 2&FINE: C *ENG 012 Thick 2&FINE: Y *ENG [0 to 3000 / 2100 / 10 V/step] [Charge...
Page 413
SM 5-25 B230/B237/D042 Service Tables [Charge AC Current: ML] Charge Roller AC Current Adjustment for MM (Color) 2008 Displays/sets the AC current target of the charge roller for ML environment (Meddle temperature and Low humidity). DFU 001 Environmental Target: Bk *ENG [0 to 3000 / 1040 / 10 μA/step] 002 Environmental Target: M *ENG 003 Environmental Target: C *ENG [0 to 3000 / 1030 / 10 μA/step] 004 Environmental Target: Y *ENG [0 to 3000 / 1070 / 10 μA/step] [Charge AC...
Page 414
B230/B237/D042 5-26 SM [Charge AC Current: HH] Charge Roller AC Current Adjustment for HH (Color) 2011 Displays/sets the AC current target of the charge roller for HH environment (High temperature and High humidity). DFU 001 Environmental Target: Bk *ENG [0 to 3000 / 940 / 10 μA/step] 002 Environmental Target: M *ENG 003 Environmental Target: C *ENG [0 to 3000 / 930 / 10 μA/step] 004 Environmental Target: Y *ENG [0 to 3000 / 960 / 10 μA/step] 2012 [Charge Output Control]...
Page 415
SM 5-27 B230/B237/D042 Service Tables 1: LL, 2: ML, 3: MM, 4: MH, 5: HH 003 Absolute Humidity: Threshold 1 *ENGChanges the humidit y threshold between LL and ML. [0 to 100 / 4.3 / 0.01 g/m 3/step] 004 Absolute Humidity: Threshold 2 *ENGChanges the humidit y threshold between ML and MM. [0 to 100 / 11 . 3 / 0.01 g/m 3/step] 005 Absolute Humidity: Threshold 3 *ENGChanges the humidit y threshold between MM and MH. [0 to 100 / 18.0 / 0.01 g/m 3/step] 006 Absolute Humidity:...
Page 416
B230/B237/D042 5-28 SM [Color Registration Correction] FA 2101 These values are the parameters for t he automatic line position adjustment and are adjusted at the factory. However, you must input a value for SP2101-001 after replacing the laser optics housing unit. For deta ils, see Laser Optics Housing Unit in the Replacement and Adjustment section. The value should be provided with the new laser optics housing unit. 001 Main Dot: Bk *ENG 002 Main Dot: M *ENG 003 Main Dot: C...
Page 417
SM 5-29 B230/B237/D042 Service Tables 006 Main Mag.: Low Speed: M *ENG 007 Main Mag.: High Speed: C *ENG 008 Main Mag.: Medium Speed: C *ENG 009 Main Mag.: Low Speed: C *ENG 010 Main Mag.: High Speed: Y *ENG 011 Main Mag.: Medium Speed: Y *ENG 012 Main Mag.: Low Speed: Y *ENG 2103 [Erase Margin Adjustment] (Area, Paper Size) Adjusts the erase margin by del eting image data at the margins. 001 Lead Edge Width *ENG 002 Trail. Edge Width *ENG [0 to 9.9 / 4.2 / 0.1...
Page 418
B230/B237/D042 5-30 SM 2105 [LD Power Adj .] (Process Speed, Color) Displays the LD power of each color for each process speed. Each LD power setting is dec ided by process control. 001 High Speed: Bk *ENG 002 High Speed: M *ENG 003 High Speed: C *ENG 004 High Speed: Y *ENG 005 Middle Speed: Bk *ENG 006 Middle Speed: M *ENG 007 Middle Speed: C *ENG 008 Middle Speed: Y *ENG 009 Low Speed: Bk *ENG 010 Low Speed: M *ENG 011 Low Speed: C *ENG 012 Low Speed: Y...
Page 419
SM 5-31 B230/B237/D042 Service Tables 002 Shading Correction Flag *ENG [0 or 1 / 1 / 1 /step] [Test Pattern] 2109 Generates the test pattern usi ng COPY Window tab in the LCD. 003 Pattern Selection - [0 to 23 / 0 / 1/step] 0 None 1: 1-dot line pattern (Vertical) 2: 2-dot line pattern (Vertical) 3: 1-dot line pattern (Horizontal) 4: 2-dot line pattern (Horizontal) 5: 1-dot grid pattern (Vertical) 6: 1-dot grid pattern (Horizontal) 7: 1-dot grid pattern (Fine) 8: 1-dot grid...
Page 420
B230/B237/D042 5-32 SM 007 Density: M - 008 Density: C - 009 Density: Y - pattern. [0 to 15 / 15 / 1 /step] 0: Lightest density 15: Darkest density 2111 [Forced Line Position Adj.] 001 Mode a - Executes the fine li ne position adjustment twice. If this SP is not completed (NG is displayed), do SP2111-003 first and then try this SP again. 002 Mode b - Executes the fine li ne position adjustment once. If this SP is not completed, do SP2111-003 first and then try this SP again....