94
■Cable Compensation/VD2/DATA
This window configures the following parameters of each
camera: the cable length for transmission loss compensa-
tion and whether to send the VD2 timing pulse or control
data with the camera output signals.
●How to Display
To display this window, click on the  (Cable
Compensation/VD2) button in the main window (p. 80).
●Parameters
Cable Comp:Select the cable length for each camera.
S: Less than 400 m (1 300 ft)
M:400 m (1 300 ft) to 700 m (2 300 ft)
L: 700 m (2 300 ft) to...

Page 92

95
(Cancel Exit) button
Cancels the configuration and closes the Camera Title win-
dow. 
●Edit Camera Title
1. Select the desired camera in the drop-down menu to
edit its camera title. The cursor blinks at the first block
in the text box.
2. Click on the  button to move the cursor to the
desired position.
3. Click on the desired character button in the Fixed Font
or User Font box. The character will be entered in the
text box.
4. Repeat Step 2 and 3 to enter the camera title.
5. After the entry, click on...

Page 93

96
Note:The new character has not been saved in the
configuration data at this point. After closing the
Edit Font window, be sure to return to the Camera
Title window and click on the  (Save Exit) but-
ton.
• To Copy a Character
1. Click on the desired character in the User Font box.
2. Click on the Copy button.
3. Click on the blank in the User Font box to copy the
character.
4. Click the Paste button. 
• To Delete a Character
1. Click on the desired character in the User Font box.
2. Click on the...

Page 94

97
●Parameters (Slave 1 to 4)
The following are different from normal connection and
Master.
•RS485, DATA1 to 3 is fixed to Camera.
•DATA 4 is used for master-slave connection. Protocol is
fixed to Master-Slave and Baud Rate is fixed to 38400.
•When VCR is selected for 600 RECORDER in SETUP
MENU (refer to p. 71), the Protocol of SERIAL is fixed to
VCR. This parameter is activated when using a
Pananonic time-lapse VCR.
•When Protocol of SERIAL is displayed as “– – –“, Baud
Rate is set to the baud rate for...

Page 95

98
• EXT IN
This stands for the setting of the EXT IN connector at the
units rear panel. 
GEN LOCK ON: Select this mode to gen-lock the unit
with the recorder.
GEN LOCK OFF:Select this mode if the asynchronous
unit is connected to the recorder.
Notes:
•If GENLOCK ON is selected, the playback images can-
not be displayed on the monitors which are connected
to the connectors MONITOR OUT 1 to 4. Confirm the
images on those which are connected to the recorder.
•If GENLOCK OFF is selected, the maximum rate...

Page 96

99
Secret View:Select the desired setting by clicking on
the drop-down menu. 
ON:The adjoining drop-down menu becomes also
active so that you can designate the desired
monitor (MON 1 to 4) for the secret view func-
tion. If you designate MON 1 in the drop-down
menu, black image will be displayed in a seg-
ment of multiscreen monitor, instead of the spot
image of camera channel activated in MON 1.
OFF:Secret view function is unavailable. 
The factory default setting is OFF.
Sequence Mode:Select the...

Page 97

100
(Save Exit) button
Saves the configuration and closes the Multiplexer Mode
window.
(Cancel Exit) button
Cancels the configuration and closes the Multiplexer Mode
window.
●Mux Alarm Group
This is a submenu of the Multiplexer window. In this win-
dow, up to 4 cameras are given recording priority for each
alarm input.
•Click a drop-down menu to assign the camera numbers
(1 to 16) to each alarm group (Group1 to 16). The facto-
ry default setting is same as the illustration.
•To configure Group 9 to 16,...

Page 98

101
■New
●How to Display
To display this window, click on the  (New) button in the
main window (p. 80).
●Parameters
This window is used for new file creation.
File Name:Enter a desired name for a new file.
Files of type:The file extension is displayed here.
(OK) button
Saves the configuration and closes the New window.
(Cancel Exit) button
Saves the configuration and closes the New window.
■Select Setup Data File
The setup file is selectable by pressing this button.
Refer to the operating instructions of...

Page 99

102
(Add Account) button
To register a new operator, click on this button. The
Registration window will appear.
(EDIT) button:To configure the operator information,
click on this button.
(DELETE) button
To delete the operator selected in the Accounts group,
click on this button.
(Save Exit) button
Saves the configuration and closes the Account Manager
window.
(Cancel Exit) button
Cancels the configuration and closes the Account Manager
window.
●Edit Account Manager
Add a Registration Operator
1. Click on...

Page 100

103
OPERATING PROCEDURES
(TERMINAL MODE) 
Start reading Panasonic Matrix Switcher Wj Sx150a Operating Instructions