Page 51
53 ●Video Cable Connection Connect the camera input connectors of Master and the monitor output connectors of Slave with coaxial cables as described in the diagram. ●DATA Port Connection •Connect the DATA 3 port of the Master unit and the DATA 4 port of the Slave units. •Connect the Master and Slave units with the supplied crossing cable. •Connect Slave and Slave with Cable Kit WV-CA48/10K. •Set the termination selectors of the Master and terminal Slave unit to ON. •Set the termination selectors of other...
Page 52
54 Connect the cameras and the Master/Slave 1 to 4 with the coaxial cables according to the diagram. ●Recorder Connection Connect recorders to each Master/Slave units. Refer to pp. 40 to 47 for connection procedures. Example:Master, Slave 1 and 2 are connected in the system. Notes: •Recorders and/or the Multiplexer board cannot be connected to the Master unit when Slave 1 to 4 are connected in the system. •The Master unit’s camera channels which loop thru Slave units cannot be connected to the recorder....
Page 53
55 ●Connection with the PC Connect the PC and the Master unit. (Refer to p. 48 for the connection procedure.) ●Software Setup After connecting the PC to the Master unit, do the setup procedure with SETUP MENU or WJ-SX150A Administrator Console. • With SETUP MENU 1. Turn the power of each unit to ON. 2. Log-in the system with a system controller. (Refer to p. 104.) 3. Open SETUP MENU. (Refer to p. 63.) 4. Open “700 SYSTEM” - “710 MASTER-SLAVE”. (Refer to pp. 72 and 73.) 5. Set the connected Slave units to...
Page 55
58 FIRMWARE UPDATE This setting is required when there is a firmware version dif- ference among each unit in the master-slave connection. Before the procedure, confirm the versions written on the label on each CD-ROM. ■Installation of SX150A Program Writer Note:Refer to p. 79 for the platform necessary for installa- tion. 1. Insert the supplied CD-ROM into the PC. 2. Open the CD-ROM drive window. The file is located in the following directory. E: \PWriter\SetupPWriter.exe (E is the CD-ROM drive.) 3....
Page 56
59 5.Click on the OK button in Version confirmation mode win- dow. Note:If the selector settings are wrong when you do Step 5, the following message will appear to notify that version confirmation was failed. In this case, confirm the connections and do Step 1 to 5 again. 6. Turn off the Master unit. 7. Set the mode selector as shown in the Firmware update mode window. 8. Turn on the unit again. 9. Click on the OK button. The unit will be set to the firmware update mode. 10. The Program Writer for...
Page 57
60 ■Error List The following error messages are displayed through SX150 Program Writer. ●File Error This error message is displayed during the following occa- sions. •You have selected a wrong file (whose file extension is not “. mot”) in Step 13 of p. 59. •The “.mot” file is broken. To solve this problem, select the correct file. (Refer to p. 59.) ●Not Ready This error message is displayed when the matrix switcher’s mode is not “SX150 SOFTWARE UPLOAD”. To solve this problem, do the following. 1. Power...
Page 58
61 SETUP PROCEDURES ■Setup Procedures This unit has two setting procedures. The one is SETUP MENU, which is the units on-screen dis- play (OSD). The other is WJ-SX150A Administrator Console, which operates on the PC. •SETUP MENU (OSD) The basic functions, which are essential for the operation, are configurable. However, some items are not config- urable. The settings about group sequences, operators and schedules, etc.•WJ-SX150A Administrator Console (PC) All the functions of this unit (except camera...
Page 59
62 ●Alarm Settings The operation parameters when an alarm is input to the unit are configurable. •Alarm mode: The operation mode activated along with an alarm input is configurable. Sequence mode or hold mode is selectable. Alarm mode can be set to OFF when not using it. •Alarm event: The sequence number or spot camera is selectable for the alarm event. •Alarm input (Alarm port): The alarm polarity (N. O. or N. C.) is assignable to each alarm input terminal. •It is also selectable whether to activate...
Page 60
63 WJ-SX150A SETUP MENU (OSD) The WJ-SX150A SETUP MENU (SETUP MENU) enables function controls that are not available by direct operation. Note: Only one operator can enter SETUP MENU. ■Displaying SETUP MENU To display SETUP MENU, follow the procedure below. 1. Confirm that the camera and peripherals are correctly and securely connected and that all components are turned on. 2. To execute the selection, select one of the monitors (1 to 4) by pressing the numeric button, then press the MON (ESC) button....