Panasonic Matrix Switcher Wj Sx150a Operating Instructions
Here you can view all the pages of manual Panasonic Matrix Switcher Wj Sx150a Operating Instructions. The Panasonic manuals for Recording Equipment are available online for free. You can easily download all the documents as PDF.
Page 31
33 SYSTEM CONNECTION EXAMPLES ■Basic System Connection This is an example of basic system connection. Camera 16 Camera 1Camera 2Camera 3 CAMERA IN 1 to 16 ALARM IN 1 to 16 Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 Matrix Switcher Note:Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP MENU or WJ-SX150A Administrator Console. ■System Expansion Connection ●Connection with Digital Disk Recorder WJ-HD500 Series or...
Page 32
34 Notes: •Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP MENU or WJ-SX150A Administrator Console. •If an optional network board is installed inside the recorder and you are to control it from LAN (local area network) or the Internet, refer to a service manual procurable in your area. ●Connection with Digital Disk Recorder WJ-HD100 Series or Time-lapse VCR •With the Multiplexer board, the recorded images of Camera 1 to 16 can be multiplexed to...
Page 33
35 ●Master-slave Connection When applying this connection, up to 5 matrix switchers and 64 cameras can be connected in a surveillance control system. One of the matrix switchers is designated as Master and the others are designated as Slave. ALARM IN 1 to 16 Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 Matrix Switcher Camera 16 Camera 1 Camera 2Camera 3 CAMERA IN 1 to 16 ALARM IN 1 to 16 Camera 48 Camera 33 Camera 34Camera 35 CAMERA IN 1 to 16 ALARM IN 1 to 16 Matrix...
Page 34
36 Connect non-multiplex type cameras to the CAMERA IN connectors 1 to 16. For cameras equipped with RS-485 communication facilities, connect the RS-485 cable as fol- lows. Check the camera addresses when using RS-485 cameras. Operations from the system controller will be invalid if the camera addresses are set improperly. •Use addresses from 1 to 16 for individual cameras. •Do not set the same address for more than one camera in an RS-485 chain. •Before connecting the RS-485 camera(s) to DATA 1, 2...
Page 35
37 ■ Connection for RS-485 Type Camera There are two options to connect the camera with the matrix switcher, depending on the distance between them. One is Home Run wiring and the other is daisy chain wiring. Home Run wiring has the transmission stability with less transmission loss, and daisy chain wiring has connec- tion flexibility with less data ports occupied. For data-multi- plex type cameras, 900 meters (3 000 ft) is the limit to use coaxial cable such as RG-59/U, BELDEN 9259 or equiva- lent....
Page 36
38 ■ Connection with the Monitors Connect the monitors to the MONITOR OUT connectors at the units rear panel with the coaxial cable. The connectors MONITOR OUT 1 to 4 are associated to Monitor 1 to 4. When you control the monitors from a PS· Data controller, the connectors MONITOR OUT are associ- ated to Unit 1 to 4. Martix Switcher Monitor 1 Monitor 2 Monitor 4 Monitor 3 2 14 3MONITOR OUT (A)(B)GND OFF ON(A)(B)GND OFF ON WV-CPR450 and others Set it to 2 or 4 (the same as the connected equipment). The...
Page 37
39 ■ Connection with the Alarm Sensors Connect the sensor switches to the units alarm port, as shown in the example. Notes: •Alarm inputs that are simultaneous or with very short intervals will be ignored. Allow for at least 100 ms interval from one alarm input to the next. •Confirm the alarm sensor type (N.O. or N.C.) and con- figure the system through SETUP MENU (OSD) or WJ- SX150A Administrator Console. The factory setting is N.O. N.O.:Normally Open alarm contact N.C.:Normally Closed alarm contact...
Page 38
40 ■Connection with Digital Disk Recorder WJ-HD500 Series Note: Refer to a service manual procurable in your area, for details on the connection with a recorder (after the net- work board installation) to operate via LAN or the Internet. ●To Confirm the Images from a Recorder Connected to the Unit The following is the description of the connection between a recorder and this unit to confirm the images from the recorder. 1. Set the unit address of the recorder to 1. Then, confirm that the recorder’s...
Page 39
41 ●To Record the Camera Images in Maximum Recording Rate The following is the description of the connection between a recorder and this unit for the maximum-rate recording. 1.Set the unit address of the recorder to 1. Then, set the recorder’s CAMERA GENLOCK to ON in its SETUP MENU. (Refer to the recorders operating instructions.) 2.Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 3.Connect the unit’s EXT IN connector to the recorder’s...
Page 40
42 ●To Control a Recorder via the Network The following is the description of the connection between a recorder and this unit to control the recorder via the net- work. 1. Set the recorders unit address to a number 5 or larger . (Refer to the recorders operating instructions.) 2. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 3. Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA port with a daisy chain connec- tion...