    SYSTEM CONNECTION EXAMPLES
    ■Basic System Connection
    This is an example of basic system connection. 
    Camera
    16 Camera
    1Camera
    2Camera
    3
    CAMERA IN 1 to 16
    ALARM IN 1 to 16 
    Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 Matrix Switcher
    Note:Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP
    MENU or WJ-SX150A Administrator Console.
    ■System Expansion Connection
    ●Connection with Digital Disk Recorder WJ-HD500 Series or WJ-HD200 Series
    When connecting the camera output connectors to Digital Disk Recorder WJ-HD500 or WJ-HD200 Series, the digital disk
    recorder can record all the camera channels. More than one camera images can be displayed in multiscreen segments on the
    desired monitor.
    Camera
    16 Camera
    1Camera
    2Camera
    3
    CAMERA IN 1 to 16
    ALARM IN 1 to 16
    Recorder
    Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4
    Available for live or play-backed camera images
    (GENLOCK OFF)
    Matrix Switcher 
    						
    							34
    Notes:
    •Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP MENU or
    WJ-SX150A Administrator Console.
    •If an optional network board is installed inside the recorder and you are to control it from LAN (local area network) or the
    Internet, refer to a service manual procurable in your area.
    ●Connection with Digital Disk Recorder WJ-HD100 Series or Time-lapse VCR 
    •With the Multiplexer board, the recorded images of Camera 1 to 16  can be multiplexed to Digital Disk Recorder, WJ-
    HD100 Series or a time-lapse VCR. 
    MUX
    Recorder or Time-lapse VCR
    Camera
    16 Camera
    1Camera
    2Camera
    3
    Max. 16
    Camera Inputs
    16 Alarm Inputs
    Multiplexer Board
    WJ-SXB151
    Max. 4 System Controllers 4 Monitor Outputs
    Available for surveillance or playback of the camera images Matrix Switcher
    To use WJ-HD100 Series or a time-lapse VCR as a recorder, you need to install a Multiplexer board inside the matrix
    switcher. 
    						
    							35
    ●Master-slave Connection
    When applying this connection, up to 5 matrix switchers and 64 cameras can be connected in a surveillance control system.
    One of the matrix switchers is designated as Master and the others are designated as Slave.
    ALARM IN 1 to 16 
    Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 Matrix Switcher
    Camera
    16 Camera
    1
    Camera
    2Camera
    3
    CAMERA IN
    1 to 16
    ALARM IN
    1 to 16 
    Camera
    48 Camera
    33
    Camera
    34Camera
    35
    CAMERA IN
    1 to 16
    ALARM IN
    1 to 16  Matrix Switcher
    Camera
    32 Camera
    17
    Camera
    18Camera
    19
    CAMERA IN
    1 to 16
    ALARM IN
    1 to 16 
    Camera
    64 Camera
    49
    Camera
    50Camera
    51
    CAMERA IN
    1 to 16
    ALARM IN
    1 to 16  Matrix Switcher Matrix Switcher Matrix Switcher
    Master Slave 1 Slave 2
    Slave 3 Slave 4 
    						
    							36
    Connect non-multiplex type cameras to the CAMERA IN
    connectors 1 to 16. For cameras equipped with RS-485
    communication facilities, connect the RS-485 cable as fol-
    lows.
    Check the camera addresses when using RS-485 cameras.
    Operations from the system controller will be invalid if the
    camera addresses are set improperly.
    •Use addresses from 1 to 16 for individual cameras.
    •Do not set the same address for more than one camera
    in an RS-485 chain.
    •Before connecting the RS-485 camera(s) to DATA 1, 2
    and/or 3, configure the system through WJ-SX150A
    Administrator Console.■ Connection with the Camera
    Sites
    Connect the data-multiplex type cameras (or camera site
    equipment) to the CAMERA IN connectors 1 to 16 on the
    matrix switchers rear panel.
    Notes:
    •Make sure that the cable length is less than 900 m
    (3 000 ft) between the camera site and the unit when
    using RG-59/U, BELDEN 9259 or equivalent cables. 
    •If you use locally procured cables, it is important to use
    only a data-grade cable, which is suitable for RS-485
    communication (shielded 2-wire twisted cable). 
    •When the cable length is extended, cable compensa-
    tion is available. (Refer to pp. 74 and 94.) 
    AUXAlarm
    Matrix Switcher 
    CAMERA1 12
    23
    3
    DATA  3 D ATA  2
    OUTIN
    4 45
    56
    67
    78
    89
    910
    1016
    16
    RS485(CAMERA)
    DATA  1
    24
    RS485(CAMERA)LINE
    SELECT
    CONNECTIONS 
    						
    							37
    ■ Connection for RS-485 Type Camera
    There are two options to connect the camera with the matrix
    switcher, depending on the distance between them. 
    One is Home Run wiring and the other is daisy chain
    wiring. Home Run wiring has the transmission stability with
    less transmission loss, and daisy chain wiring has connec-
    tion flexibility with less data ports occupied. For data-multi-
    plex type cameras, 900 meters (3 000 ft) is the limit to use
    coaxial cable such as RG-59/U, BELDEN 9259 or equiva-
    lent.
    Note: If more distance is required, use cameras and
    matrix switcher with RS-485 communication feature.
    Remote control becomes possible.
    ●Home Run Wiring
    1. Connect with a RS-485 camera in Home Run wiring as
    shown in the figure.
    2. Set the LINE SELECT switch to 2 or 4.
    Notes:
    •Before connecting RS-485 cameras to DATA1 to 3, data
    port setting through WJ-SX150A Administrator Console
    is necessary. (Refer to p. 96 Data Port.)
    •Recommended for RS-485 communication is AWG#22
    or thicker one. The cable should be shielded, two-wire,
    twisted pair, and with low impedance.
    •Set the LINE SELECT switch to 4 when programming
    preset position of WV-CSR600/650 Series camera is
    connected to the unit.●Daisy Chain Wiring
    1. Draw up a plan for connection between the cameras
    and the input channels of the matrix switcher, and the
    assignment of unit addresses to cameras.
    2. Set the LINE SELECT switch to 2. Also, set the connect-
    ed devices switch if required.
    3. Connect one end of the cable to RS-485 (CAMERA),
    and the other end to the first camera in the chain, as
    shown in the figure. Repeat this procedure for all cam-
    eras. 
    4. Set the termination switches of the cameras at the chain
    ends to ON. Cameras termination switches must be set
    to OFF except the ones at the chain ends.
    Notes:
    •Set the same number for the cameras unit address as
    and CAMERA IN.
    •Check the settings of the camera addresses when
    using RS-485 cameras. Operations from the system
    controller will be invalid if the camera addresses are set
    improperly.
    •Do not use addresses other than 1 to 16 for individual
    cameras (More than 17 cameras are not allowed).
    •Do not set the same address for more than one camera
    in an RS-485 chain.
    •Termination is the key to data transmission and recep-
    tion in the chain. While the other switches are set to
    OFF, only the switches at the chain ends must be set to
    ON.
    •The termination of this units RS-485 camera port is
    always set to ON. Connect the unit at the end of the
    daisy chain.
    •The more equipment there is in the chain, the slower
    the response may be.
    Matrix Switcher
    RS-485 type camera
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA)
    DATA  4
    PS•DATA DATA HDRDATA  1
    Set it to 
    position 4.
    WV-CPR450 and others  (For the 
    Termination Switch positions, refer 
    to the oprating instractions of the 
    camera.)
    (A)(B)GND
    OFF ON
    Matrix Switcher
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA)
    DATA  4DATA  1
    Set it to 
    position 2.
    DATA HDR
    PS•DATA
    RB
    RA
    TBTAGND
    NoneMatrix switchers rear panel
    TB
    TA
    RB
    RA
    RS485 Port 
    						
    							38
    ■ Connection with the Monitors
    Connect the monitors to the MONITOR OUT connectors at
    the units rear panel with the coaxial cable.
    The connectors MONITOR OUT 1 to 4 are associated to
    Monitor 1 to 4. When you control the monitors from a PS·
    Data controller, the connectors MONITOR OUT are associ-
    ated to Unit 1 to 4.
    Martix Switcher
    Monitor 1 Monitor 2 Monitor 4 Monitor 3
    2 14
    3MONITOR OUT
    (A)(B)GND
    OFF ON(A)(B)GND
    OFF ON
    WV-CPR450 and others
    Set it to 2 or 4
    (the same as
    the connected
    equipment).
    The switch on a daisy-
    chain-connected unit 
    other than the 
    extremities must be set 
    to OFF.The switch on the end 
    unit should be set to 
    ON.
    (For the termination 
    switch positions, refer 
    to the operating 
    instruction of the 
    corresponding unit.)
    Matrix Switcher
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA) PS•DATA
    DATA  4DATA  1DATA HDR
    Auto termination works inside the matrix switcher.  
    Matrix Switcher 
    CAMERA1 12
    23
    3
    DATA  3 D ATA  2
    OUTIN4 45
    56
    67
    78
    89
    910
    1016
    16
    RS485(CAMERA)
    DATA  1
    Unit address 1 Unit address 2 Unit address 3 Unit address 4
    Set the same 
    number for the 
    cameras unit 
    address as and 
    CAMERA IN. 
    						
    							39
    ■ Connection with the Alarm
    Sensors
    Connect the sensor switches to the units alarm port, as
    shown in the example.
    Notes:
    •Alarm inputs that are simultaneous or with very short
    intervals will be ignored.
    Allow for at least 100 ms interval from one alarm input to
    the next.
    •Confirm the alarm sensor type (N.O. or N.C.) and con-
    figure the system through SETUP MENU (OSD) or WJ-
    SX150A Administrator Console.
    The factory setting is N.O.
    N.O.:Normally Open alarm contact
    N.C.:Normally Closed alarm contact
    •Alarm pins assigned as the time adjusting (TIME) termi-
    nals cannot be used as alarm input terminals.
    •The specification of Recover Input:5 V DC / 0 V (low-
    active)
    Recover Input, which resets alarm signals, is Pin No. 13
    of the ALARM port. To reset alarm signals, contact GND
    and Recover Input. 
    When you connect Digital Disk Recorder WJ-HD100
    Series to the matrix switcher, set the recorders alarm
    polarity to Open-collector low by setting the MODE
    switch #6 to off.
    25 13141
    Alarm
    Sensor 1
    Alarm
    Sensor 2
    ALARMRecover
    Input
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13Alarm Input 1
    Alarm Input 3
    Alarm Input 5
    Alarm Input 7
    Alarm Input 9
    Alarm Input 11
    Alarm Input 13
    Alarm Input 15
    GND
    Alarm Output 1
    Alarm Output 3
    GND
    Recover Input Pin No. Designation
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25Alarm Input 2
    Alarm Input 4
    Alarm Input 6
    Alarm Input 8
    Alarm Input 10
    Alarm Input 12
    Alarm Input 14
    Alarm Input 16
    GND
    Alarm Output 2
    Alarm Output 4
    GND Pin No. Designation
    ■ Connection with the System
    Controllers
    Connect the system controller to the DATA 1 to 4 port at the
    units rear panel with the modular cable.
    Notes:
    •Up to four system controllers are connectable.
    •Connect them in home run.
    •In the factory default setting, the DATA 4 port is a
    PS·Data terminal. To connect a terminal-mode system
    controller to this port, you need to change the data port
    setting through SETUP MENU or WJ-SX150A
    Administrator Console. (Refer to pp. 74 or 96.)
    Matrix Switcher
    System controller System controller
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA) PS•DATA
    DATA  4 DATA HDRDATA  1
    RB
    RA
    TBTAGND
    GNDMatrix switchers rear panel
    DATA 1 to 4 
    TB
    TA
    RB
    RA
    DATA1 to DATA4 Port 
    						
    							40
    ■Connection with Digital Disk
    Recorder WJ-HD500 Series
    Note: Refer to a service manual procurable in your area, for
    details on the connection with a recorder (after the net-
    work board installation) to operate via LAN or the
    Internet.
    ●To Confirm the Images from a
    Recorder Connected to the Unit
    The following is the description of the connection between a
    recorder and this unit to confirm the images from the
    recorder.
    1. Set the unit address of the recorder to 1. Then, confirm
    that the recorder’s CAMERA GENLOCK is set to OFF in
    its SETUP MENU. (Refer to the recorders operating
    instructions.)
    2. Connect the unit’s CAM OUT 1 to 16 connectors to the
    recorder’s VIDEO IN 1 to 16 connectors with a coaxial
    cable.
    3. Connect the unit’s EXT IN connector to the recorder’s
    MULTI SCREEN OUT connector with a coaxial cable.
    4. Connect the unit’s DATA HDR connector to the
    recorder’s DATA port with a modular cable.
    (The control data and alarm signal will be output from
    the unit to the recorder.)
    Notes:
    •You cannot record the camera images in maximum
    recording rate through this connection. Refer to the next
    connection example in this page.
    Matrix SwitcherMonitor
    Recorder
    16
    1615
    1514
    1413
    1312
    1211
    1110
    109
    98
    87
    76
    65
    54
    432
    2
    3
    1
    1
    SIGNAL GND10/100BASE-TSPOT
    OUTIN EXT STORAGE COPY
    CONTROL ALARM
    VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL
    INOUT
    OUTMULTI SCREEN OUTAUDIO
    CAMERA1
    1
    2
    2
    3 3 2
    DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON4
    2
    1
    43
    EXT OUT
    (REC OUT)
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECTMONITOR OUT
    EXT IN
    (PLAY IN)
    OUT
    IN
    4
    4
    5
    5
    6
    6
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    15
    15
    16 16
    RS485(CAMERA)PS•DATA
    DATA  4 DATA HDRDATA  1
    EXT IN
    MULTI SCREEN 
    OUTDATA HDRMONITOR
    OUT
    ■Connection with the Alarm
    Output
    Pins #10, 11, 23 and 24 (open collector) turns to 0 V while
    the alarm is activated. These terminals can drive external
    warning devices such as a buzzer or lamp of up to 100 mA,
    16 V DC. If the rating exceeds 100 mA, 16 V DC use a relay
    as shown in Example 2.
    Alarm signals are output from the terminals until the reset.
    Example 1:Direct drive connection
    Example 2:Connection of devices exceeding drive
    Note:An alarm signal is output from the Master unit and a
    unit activated by the alarm. Be careful of connections
    as the Master unit outputs alarm signals to directly-con-
    nected devices any time when an alarm is activated.
    NO
    C NC
    To  Buzzer
    Relay
    +12V
    GND
    NC: Normally Closed Contact
    NO: Normally Open Contact
    C: Common
    Buzzer 
    						
    							41
    ●To Record the Camera Images in Maximum
    Recording Rate
    The following is the description of the connection between a
    recorder and this unit for the maximum-rate recording.
    1.Set the unit address of the recorder to 1. Then, set the
    recorder’s CAMERA GENLOCK to ON in its SETUP
    MENU. (Refer to the recorders operating instructions.)
    2.Connect the unit’s CAM OUT 1 to 16 connectors to the
    recorder’s VIDEO IN 1 to 16 connectors with a coaxial
    cable.
    3.Connect the unit’s EXT IN connector to the recorder’s
    GENLOCK OUT connector with a coaxial cable.
    4.Connect the unit’s DATA HDR connector to the
    recorder’s DATA port with a modular cable.
    (The control data and alarm signal will be output from
    the unit to the recorder.)
    5.After the connection, set the unit’s EXT IN to GENLOCK
    ON through SETUP MENU or WJ-SX150A Administrator
    Console (Refer to pp. 71 or 97).
    Notes:
    •You need WJ-HD500A or a newer model for the maxi-
    mum-rate recording.
    •The playback, multiscreen output or live images from the
    recorder are not displayed on Monitor 1 to 4. To confirm
    the images, you need to connect another monitor with
    the recorder. 
    •The recorder will not operate if its unit address is set to
    other than 1.
    •Make sure the recorder’s unit address is set to 1
    through SETUP MENU or WJ-SX150A Administrator
    Console. (Refer to pp. 71 or 97.) If another number is
    selected, you cannot control the recorder.
    Matrix Switcher
    Recorder
    16
    1615
    1514
    1413
    1312
    1211
    1110
    109
    98
    87
    76
    65
    54
    432
    2
    3
    1
    1
    SIGNAL GND10/100BASE-TSPOT
    OUTIN EXT STORAGE COPY
    CONTROL ALARM
    VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL
    INOUT
    OUTMULTI SCREEN OUTAUDIO
    EXT IN
    GENLOCK 
    OUT MULTI 
    SCREEN
    OUTDATA DATA HDR
    Monitor
    CAMERA1
    1
    2
    2
    3 3 2
    DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON4
    2
    1
    43
    EXT OUT
    (REC OUT)
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECTMONITOR OUT
    EXT IN
    (PLAY IN)
    OUT
    IN
    4
    4
    5
    5
    6
    6
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    15
    15
    16 16
    RS485(CAMERA)PS•DATA
    DATA  4 DATA HDRDATA  1
    •Make sure the recorder’s unit address is set to 1
    through SETUP MENU or WJ-SX150A Administrator
    Console. (Refer to pp. 71 or 97.) If another number is
    selected, you cannot control the recorder. 
    						
    							42
    ●To Control a Recorder via the
    Network
    The following is the description of the connection between
    a recorder and this unit to control the recorder via the net-
    work.
    1. Set the recorders unit address to a number 5 or larger .
    (Refer to the recorders operating instructions.)
    2. Connect the unit’s CAM OUT 1 to 16 connectors to the
    recorder’s VIDEO IN 1 to 16 connectors with a coaxial
    cable.
    3. Connect the unit’s DATA HDR and DATA4 connectors
    to the recorder’s DATA port with a daisy chain connec-
    tion cable kit (WV-CA48/10K).
    (The control data and alarm signal will be output from
    the unit to the recorder.)
    4. Select the recorder’s new unit address, which is set in
    Step 1, in 600 RECORDER (refer to p. 71 ) of SETUP
    MENU or the Recorder (refer to p. 97 ) window of WJ-
    SX150A Administrator Console.
    5. Through a browser, set the unit address of an optional
    network board (WJ-HDB502) to a number other than 1.
    (Refer to WJ-HDB502 Operating Instructions.) 
    6. Refer to p. 38, p. 40 and p. 41 for MONITOR OUT con-
    nection, MULTI SCREEN OUT connection, and EXT IN
    connection.
    Notes:
    •You will need WJ-HD500A or a newer model, in which
    an optional network board (WJ-HDB502) is installed.
    •Select the PS·Data protocol for the DATA 4 setting.
    (Refer to p. 74 CAMERA/DATA1 - 4 PORT or p. 96 Data
    Port.) If the terminal mode is selected, you cannot con-
    trol the recorder.
    •The recorder will not be operable if its unit address is
    set to 1/2/3/4.
    •If the recorders unit address in Step 1 and the recorder
    setting in Step 4 are different, the recorder will not be
    operable.
    •In these connections, you cannot use a PS·Data system
    controller.
    Matrix SwitcherMonitor
    Recorder*
    16
    1615
    1514
    1413
    1312
    1211
    1110
    109
    98
    87
    76
    65
    54
    432
    2
    3
    1
    1
    SIGNAL GND10/100BASE-TSPOT
    OUTIN EXT STORAGE COPY
    CONTROL ALARM
    VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL
    INOUT
    OUTMULTI SCREEN OUTAUDIO
    * WJ-HD500A or Newer Models with Network Board (WJ-HDB502)
    ** LAN : Local Area Network
    CAMERA1
    1
    2
    2
    3 3 2
    DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON4
    2
    1
    43
    EXT OUT
    (REC OUT)
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECT
    MONITOR OUT
    EXT IN
    (PLAY IN)
    OUT
    IN
    4
    4
    5
    5
    6
    6
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    15
    15
    16 16
    RS485(CAMERA)PS•DATA
    DATA  4 DATA HDRDATA  1
    EXT IN
    MULTI SCREEN 
    OUTDATA HDR
    DATA
    DATA4
    (PS·Data)
    MONITOR
    OUT
    Daisy Chain Connection Kit
    (WV-CA48/10K)
    HUB/Router
    LAN Cable
    10/100 BASE-T
    LAN** 
    						