33 SYSTEM CONNECTION EXAMPLES ■Basic System Connection This is an example of basic system connection. Camera 16 Camera 1Camera 2Camera 3 CAMERA IN 1 to 16 ALARM IN 1 to 16 Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 Matrix Switcher Note:Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP MENU or WJ-SX150A Administrator Console. ■System Expansion Connection ●Connection with Digital Disk Recorder WJ-HD500 Series or WJ-HD200 Series When connecting the camera output connectors to Digital Disk Recorder WJ-HD500 or WJ-HD200 Series, the digital disk recorder can record all the camera channels. More than one camera images can be displayed in multiscreen segments on the desired monitor. Camera 16 Camera 1Camera 2Camera 3 CAMERA IN 1 to 16 ALARM IN 1 to 16 Recorder Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 Available for live or play-backed camera images (GENLOCK OFF) Matrix Switcher
34 Notes: •Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP MENU or WJ-SX150A Administrator Console. •If an optional network board is installed inside the recorder and you are to control it from LAN (local area network) or the Internet, refer to a service manual procurable in your area. ●Connection with Digital Disk Recorder WJ-HD100 Series or Time-lapse VCR •With the Multiplexer board, the recorded images of Camera 1 to 16 can be multiplexed to Digital Disk Recorder, WJ- HD100 Series or a time-lapse VCR. MUX Recorder or Time-lapse VCR Camera 16 Camera 1Camera 2Camera 3 Max. 16 Camera Inputs 16 Alarm Inputs Multiplexer Board WJ-SXB151 Max. 4 System Controllers 4 Monitor Outputs Available for surveillance or playback of the camera images Matrix Switcher To use WJ-HD100 Series or a time-lapse VCR as a recorder, you need to install a Multiplexer board inside the matrix switcher.
35 ●Master-slave Connection When applying this connection, up to 5 matrix switchers and 64 cameras can be connected in a surveillance control system. One of the matrix switchers is designated as Master and the others are designated as Slave. ALARM IN 1 to 16 Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 Matrix Switcher Camera 16 Camera 1 Camera 2Camera 3 CAMERA IN 1 to 16 ALARM IN 1 to 16 Camera 48 Camera 33 Camera 34Camera 35 CAMERA IN 1 to 16 ALARM IN 1 to 16 Matrix Switcher Camera 32 Camera 17 Camera 18Camera 19 CAMERA IN 1 to 16 ALARM IN 1 to 16 Camera 64 Camera 49 Camera 50Camera 51 CAMERA IN 1 to 16 ALARM IN 1 to 16 Matrix Switcher Matrix Switcher Matrix Switcher Master Slave 1 Slave 2 Slave 3 Slave 4
36 Connect non-multiplex type cameras to the CAMERA IN connectors 1 to 16. For cameras equipped with RS-485 communication facilities, connect the RS-485 cable as fol- lows. Check the camera addresses when using RS-485 cameras. Operations from the system controller will be invalid if the camera addresses are set improperly. •Use addresses from 1 to 16 for individual cameras. •Do not set the same address for more than one camera in an RS-485 chain. •Before connecting the RS-485 camera(s) to DATA 1, 2 and/or 3, configure the system through WJ-SX150A Administrator Console.■ Connection with the Camera Sites Connect the data-multiplex type cameras (or camera site equipment) to the CAMERA IN connectors 1 to 16 on the matrix switchers rear panel. Notes: •Make sure that the cable length is less than 900 m (3 000 ft) between the camera site and the unit when using RG-59/U, BELDEN 9259 or equivalent cables. •If you use locally procured cables, it is important to use only a data-grade cable, which is suitable for RS-485 communication (shielded 2-wire twisted cable). •When the cable length is extended, cable compensa- tion is available. (Refer to pp. 74 and 94.) AUXAlarm Matrix Switcher CAMERA1 12 23 3 DATA 3 D ATA 2 OUTIN 4 45 56 67 78 89 910 1016 16 RS485(CAMERA) DATA 1 24 RS485(CAMERA)LINE SELECT CONNECTIONS
37 ■ Connection for RS-485 Type Camera There are two options to connect the camera with the matrix switcher, depending on the distance between them. One is Home Run wiring and the other is daisy chain wiring. Home Run wiring has the transmission stability with less transmission loss, and daisy chain wiring has connec- tion flexibility with less data ports occupied. For data-multi- plex type cameras, 900 meters (3 000 ft) is the limit to use coaxial cable such as RG-59/U, BELDEN 9259 or equiva- lent. Note: If more distance is required, use cameras and matrix switcher with RS-485 communication feature. Remote control becomes possible. ●Home Run Wiring 1. Connect with a RS-485 camera in Home Run wiring as shown in the figure. 2. Set the LINE SELECT switch to 2 or 4. Notes: •Before connecting RS-485 cameras to DATA1 to 3, data port setting through WJ-SX150A Administrator Console is necessary. (Refer to p. 96 Data Port.) •Recommended for RS-485 communication is AWG#22 or thicker one. The cable should be shielded, two-wire, twisted pair, and with low impedance. •Set the LINE SELECT switch to 4 when programming preset position of WV-CSR600/650 Series camera is connected to the unit.●Daisy Chain Wiring 1. Draw up a plan for connection between the cameras and the input channels of the matrix switcher, and the assignment of unit addresses to cameras. 2. Set the LINE SELECT switch to 2. Also, set the connect- ed devices switch if required. 3. Connect one end of the cable to RS-485 (CAMERA), and the other end to the first camera in the chain, as shown in the figure. Repeat this procedure for all cam- eras. 4. Set the termination switches of the cameras at the chain ends to ON. Cameras termination switches must be set to OFF except the ones at the chain ends. Notes: •Set the same number for the cameras unit address as and CAMERA IN. •Check the settings of the camera addresses when using RS-485 cameras. Operations from the system controller will be invalid if the camera addresses are set improperly. •Do not use addresses other than 1 to 16 for individual cameras (More than 17 cameras are not allowed). •Do not set the same address for more than one camera in an RS-485 chain. •Termination is the key to data transmission and recep- tion in the chain. While the other switches are set to OFF, only the switches at the chain ends must be set to ON. •The termination of this units RS-485 camera port is always set to ON. Connect the unit at the end of the daisy chain. •The more equipment there is in the chain, the slower the response may be. Matrix Switcher RS-485 type camera 2 DATA 3 D ATA 2 TERM OFF ON 4 RS485(CAMERA)LINE SELECT RS485(CAMERA) DATA 4 PS•DATA DATA HDRDATA 1 Set it to position 4. WV-CPR450 and others (For the Termination Switch positions, refer to the oprating instractions of the camera.) (A)(B)GND OFF ON Matrix Switcher 2 DATA 3 D ATA 2 TERM OFF ON 4 RS485(CAMERA)LINE SELECT RS485(CAMERA) DATA 4DATA 1 Set it to position 2. DATA HDR PS•DATA RB RA TBTAGND NoneMatrix switchers rear panel TB TA RB RA RS485 Port
38 ■ Connection with the Monitors Connect the monitors to the MONITOR OUT connectors at the units rear panel with the coaxial cable. The connectors MONITOR OUT 1 to 4 are associated to Monitor 1 to 4. When you control the monitors from a PS· Data controller, the connectors MONITOR OUT are associ- ated to Unit 1 to 4. Martix Switcher Monitor 1 Monitor 2 Monitor 4 Monitor 3 2 14 3MONITOR OUT (A)(B)GND OFF ON(A)(B)GND OFF ON WV-CPR450 and others Set it to 2 or 4 (the same as the connected equipment). The switch on a daisy- chain-connected unit other than the extremities must be set to OFF.The switch on the end unit should be set to ON. (For the termination switch positions, refer to the operating instruction of the corresponding unit.) Matrix Switcher 2 DATA 3 D ATA 2 TERM OFF ON 4 RS485(CAMERA)LINE SELECT RS485(CAMERA) PS•DATA DATA 4DATA 1DATA HDR Auto termination works inside the matrix switcher. Matrix Switcher CAMERA1 12 23 3 DATA 3 D ATA 2 OUTIN4 45 56 67 78 89 910 1016 16 RS485(CAMERA) DATA 1 Unit address 1 Unit address 2 Unit address 3 Unit address 4 Set the same number for the cameras unit address as and CAMERA IN.
39 ■ Connection with the Alarm Sensors Connect the sensor switches to the units alarm port, as shown in the example. Notes: •Alarm inputs that are simultaneous or with very short intervals will be ignored. Allow for at least 100 ms interval from one alarm input to the next. •Confirm the alarm sensor type (N.O. or N.C.) and con- figure the system through SETUP MENU (OSD) or WJ- SX150A Administrator Console. The factory setting is N.O. N.O.:Normally Open alarm contact N.C.:Normally Closed alarm contact •Alarm pins assigned as the time adjusting (TIME) termi- nals cannot be used as alarm input terminals. •The specification of Recover Input:5 V DC / 0 V (low- active) Recover Input, which resets alarm signals, is Pin No. 13 of the ALARM port. To reset alarm signals, contact GND and Recover Input. When you connect Digital Disk Recorder WJ-HD100 Series to the matrix switcher, set the recorders alarm polarity to Open-collector low by setting the MODE switch #6 to off. 25 13141 Alarm Sensor 1 Alarm Sensor 2 ALARMRecover Input 1 2 3 4 5 6 7 8 9 10 11 12 13Alarm Input 1 Alarm Input 3 Alarm Input 5 Alarm Input 7 Alarm Input 9 Alarm Input 11 Alarm Input 13 Alarm Input 15 GND Alarm Output 1 Alarm Output 3 GND Recover Input Pin No. Designation 14 15 16 17 18 19 20 21 22 23 24 25Alarm Input 2 Alarm Input 4 Alarm Input 6 Alarm Input 8 Alarm Input 10 Alarm Input 12 Alarm Input 14 Alarm Input 16 GND Alarm Output 2 Alarm Output 4 GND Pin No. Designation ■ Connection with the System Controllers Connect the system controller to the DATA 1 to 4 port at the units rear panel with the modular cable. Notes: •Up to four system controllers are connectable. •Connect them in home run. •In the factory default setting, the DATA 4 port is a PS·Data terminal. To connect a terminal-mode system controller to this port, you need to change the data port setting through SETUP MENU or WJ-SX150A Administrator Console. (Refer to pp. 74 or 96.) Matrix Switcher System controller System controller 2 DATA 3 D ATA 2 TERM OFF ON 4 RS485(CAMERA)LINE SELECT RS485(CAMERA) PS•DATA DATA 4 DATA HDRDATA 1 RB RA TBTAGND GNDMatrix switchers rear panel DATA 1 to 4 TB TA RB RA DATA1 to DATA4 Port
40 ■Connection with Digital Disk Recorder WJ-HD500 Series Note: Refer to a service manual procurable in your area, for details on the connection with a recorder (after the net- work board installation) to operate via LAN or the Internet. ●To Confirm the Images from a Recorder Connected to the Unit The following is the description of the connection between a recorder and this unit to confirm the images from the recorder. 1. Set the unit address of the recorder to 1. Then, confirm that the recorder’s CAMERA GENLOCK is set to OFF in its SETUP MENU. (Refer to the recorders operating instructions.) 2. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 3. Connect the unit’s EXT IN connector to the recorder’s MULTI SCREEN OUT connector with a coaxial cable. 4. Connect the unit’s DATA HDR connector to the recorder’s DATA port with a modular cable. (The control data and alarm signal will be output from the unit to the recorder.) Notes: •You cannot record the camera images in maximum recording rate through this connection. Refer to the next connection example in this page. Matrix SwitcherMonitor Recorder 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 3 1 1 SIGNAL GND10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL INOUT OUTMULTI SCREEN OUTAUDIO CAMERA1 1 2 2 3 3 2 DATA 3 D ATA 2SERIAL ALARM TERM OFF ON4 2 1 43 EXT OUT (REC OUT) CAMERA SW INRS485(CAMERA)LINE SELECTMONITOR OUT EXT IN (PLAY IN) OUT IN 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 RS485(CAMERA)PS•DATA DATA 4 DATA HDRDATA 1 EXT IN MULTI SCREEN OUTDATA HDRMONITOR OUT ■Connection with the Alarm Output Pins #10, 11, 23 and 24 (open collector) turns to 0 V while the alarm is activated. These terminals can drive external warning devices such as a buzzer or lamp of up to 100 mA, 16 V DC. If the rating exceeds 100 mA, 16 V DC use a relay as shown in Example 2. Alarm signals are output from the terminals until the reset. Example 1:Direct drive connection Example 2:Connection of devices exceeding drive Note:An alarm signal is output from the Master unit and a unit activated by the alarm. Be careful of connections as the Master unit outputs alarm signals to directly-con- nected devices any time when an alarm is activated. NO C NC To Buzzer Relay +12V GND NC: Normally Closed Contact NO: Normally Open Contact C: Common Buzzer
41 ●To Record the Camera Images in Maximum Recording Rate The following is the description of the connection between a recorder and this unit for the maximum-rate recording. 1.Set the unit address of the recorder to 1. Then, set the recorder’s CAMERA GENLOCK to ON in its SETUP MENU. (Refer to the recorders operating instructions.) 2.Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 3.Connect the unit’s EXT IN connector to the recorder’s GENLOCK OUT connector with a coaxial cable. 4.Connect the unit’s DATA HDR connector to the recorder’s DATA port with a modular cable. (The control data and alarm signal will be output from the unit to the recorder.) 5.After the connection, set the unit’s EXT IN to GENLOCK ON through SETUP MENU or WJ-SX150A Administrator Console (Refer to pp. 71 or 97). Notes: •You need WJ-HD500A or a newer model for the maxi- mum-rate recording. •The playback, multiscreen output or live images from the recorder are not displayed on Monitor 1 to 4. To confirm the images, you need to connect another monitor with the recorder. •The recorder will not operate if its unit address is set to other than 1. •Make sure the recorder’s unit address is set to 1 through SETUP MENU or WJ-SX150A Administrator Console. (Refer to pp. 71 or 97.) If another number is selected, you cannot control the recorder. Matrix Switcher Recorder 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 3 1 1 SIGNAL GND10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL INOUT OUTMULTI SCREEN OUTAUDIO EXT IN GENLOCK OUT MULTI SCREEN OUTDATA DATA HDR Monitor CAMERA1 1 2 2 3 3 2 DATA 3 D ATA 2SERIAL ALARM TERM OFF ON4 2 1 43 EXT OUT (REC OUT) CAMERA SW INRS485(CAMERA)LINE SELECTMONITOR OUT EXT IN (PLAY IN) OUT IN 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 RS485(CAMERA)PS•DATA DATA 4 DATA HDRDATA 1 •Make sure the recorder’s unit address is set to 1 through SETUP MENU or WJ-SX150A Administrator Console. (Refer to pp. 71 or 97.) If another number is selected, you cannot control the recorder.
42 ●To Control a Recorder via the Network The following is the description of the connection between a recorder and this unit to control the recorder via the net- work. 1. Set the recorders unit address to a number 5 or larger . (Refer to the recorders operating instructions.) 2. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 3. Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA port with a daisy chain connec- tion cable kit (WV-CA48/10K). (The control data and alarm signal will be output from the unit to the recorder.) 4. Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER (refer to p. 71 ) of SETUP MENU or the Recorder (refer to p. 97 ) window of WJ- SX150A Administrator Console. 5. Through a browser, set the unit address of an optional network board (WJ-HDB502) to a number other than 1. (Refer to WJ-HDB502 Operating Instructions.) 6. Refer to p. 38, p. 40 and p. 41 for MONITOR OUT con- nection, MULTI SCREEN OUT connection, and EXT IN connection. Notes: •You will need WJ-HD500A or a newer model, in which an optional network board (WJ-HDB502) is installed. •Select the PS·Data protocol for the DATA 4 setting. (Refer to p. 74 CAMERA/DATA1 - 4 PORT or p. 96 Data Port.) If the terminal mode is selected, you cannot con- trol the recorder. •The recorder will not be operable if its unit address is set to 1/2/3/4. •If the recorders unit address in Step 1 and the recorder setting in Step 4 are different, the recorder will not be operable. •In these connections, you cannot use a PS·Data system controller. Matrix SwitcherMonitor Recorder* 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 3 1 1 SIGNAL GND10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL INOUT OUTMULTI SCREEN OUTAUDIO * WJ-HD500A or Newer Models with Network Board (WJ-HDB502) ** LAN : Local Area Network CAMERA1 1 2 2 3 3 2 DATA 3 D ATA 2SERIAL ALARM TERM OFF ON4 2 1 43 EXT OUT (REC OUT) CAMERA SW INRS485(CAMERA)LINE SELECT MONITOR OUT EXT IN (PLAY IN) OUT IN 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 RS485(CAMERA)PS•DATA DATA 4 DATA HDRDATA 1 EXT IN MULTI SCREEN OUTDATA HDR DATA DATA4 (PS·Data) MONITOR OUT Daisy Chain Connection Kit (WV-CA48/10K) HUB/Router LAN Cable 10/100 BASE-T LAN**