Home > Panasonic > Recording Equipment > Panasonic Matrix Switcher Wj Sx150a Operating Instructions

Panasonic Matrix Switcher Wj Sx150a Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Matrix Switcher Wj Sx150a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							155
    PAN/TILT ItemTransmission Command
    (ASCII)Response (ASCII) Parameter (ASCII)CMD:CmmPTccxxyy — mm=Monitor No.
    cc=Camera No. 
    • Panning speed
    xx=00  STOP
    xx=01 to 40(HEX) + direction panning
    (Max is 40 and min is 01)
    xx=81 to C0(HEX) - direction panning
    (Max is C0 and min is 81)
    • Tilting speed
    yy=00  STOP
    yy=01 to 40(HEX) + direction tilting 
    (Max is 40 and min is 01)
    yy=81 to C0(HEX) - direction tilting
    (Max is C0 and min is 81)
    Camera Control
    CMD:CmmZMccn Zoom — mm=Monitor No.
    cc=Camera No. 
    n=0  STOP
    n=1  TELE
    n=2  WIDE
    Focus CMD:CmmFCccn — mm=Monitor No.
    cc=Camera No.
    n=0  STOP
    1  NEAR
    2  FAR
    3  AUTO FOCUS
    Iris CMD:CmmIRccn — mm=Monitor No.
    cc=Camera No.
    n=0  STOP
    n=1  OPEN
    n=2  CLOSE
    n=3  AUTO IRIS 
    						
    							156 156
    AUX2 CMD:CmmA2ccn —mm=Monitor No.
    cc=Camera No.
    n=0 OFF
    n=1 ON AUX1 CMD:CmmA1ccn —mm=Monitor No.
    cc=Camera No.
    n=0 OFF
    n=1 ON
    mm=Monitor No.
    cc=Camera No.
    n=0 OFF (Color)
    n=1 ON (BW)
    mm=Monitor No.
    cc=Camera No.
    n=0 STOP
    n=1 PLAY
    n=2 LEARN
    mm=Monitor No.
    cc=Camera No.
    nnn=Camera function No. (001 to 256) ItemTransmission Command
    (ASCII)Response (ASCII) Parameter (ASCII)
    Cameras SETUP MENU  CMD:CmmCMccn — mm=Monitor No.
    cc=Camera No.
    n=0 OFF
    n=1 ON
    The following commands are available in
    SETUP MENU:
    CMD:AmmJL (Move the cursor leftward)
    CMD:AmmJR (Move the cursor rightward)
    CMD:AmmJU (Move the cursor upward)
    CMD:AmmJD (Move the cursor downward)
    CMD:AmmST (SET)
    CMD:AmmES (ESC)
    CMD:AmmIN (RESET)
    CMD:AmmDE (ALL RESET)
    Program Preset Position CMD:CmmPSccnn —mm=Monitor No.
    cc=Camera No.
    nn=01 to 64 Preset position No. Call Preset Position CMD:CmmPMccnn — mm=Monitor No.
    cc=Camera No.
    nn=01 to 64 Preset position No.
    nn=00 Home position
    Color/BW CMD:CmmBWccn —
    Patrol CMD:CmmPAccn —
    Camera Function CMD:CmmCFccnnn —
    Auto Panning CMD:CmmAPccn —mm=Monitor No.
    cc=Camera No.
    n=0  AUTO PAN
    n=1  AUTO SORT
    n=2  AUTO SEQ
    Wiper CMD:CmmWPccn —mm=Monitor No.
    cc=Camera No.
    n=0  OFF
    n=1  ON
    Defroster CMD:CmmDFccn —mm=Monitor No.
    cc=Camera No.
    n=0  OFF
    n=1  ON 
    						
    							157157
    Transmission command toggles zoom.
    mm=Monitor No.
    n=0  Zoom OFF
    n=1 + mark display ON*
    n=2  Two-fold zoom
    n=4  x4Live image/Playback image
    n=8  x8Live image/Playback image
    *Available only with the Multiplexer board CMD:RmmZM Multiscreen segment switch-
    ing
    Recorder Control
    ItemTransmission Command
    (ASCII)Response (ASCII) Parameter (ASCII)
    CMD:RmmML ANS:RmmML mm=Monitor No.
    Electronic Zoom ANS:RmmZMn
    Play CMD:RmmPL ANS:RmmPL mm=Monitor No.
    Pause CMD:RmmPA ANS:RmmPA mm=Monitor No.
    Stop CMD:RmmSPn ANS:RmmSPn mm=Monitor No.
    n=0   Stop playback 
    n=1   Stop recording
    Recorder button CMD:HmmRSnn ANS:HmmRSnn nn=00 Master recorder selected
    nn=01 Slave 1 recorder selected
    nn=02 Slave 2 recorder selected
    nn=03 Slave 3 recorder selected
    nn=04 Slave 4 recorder selected
    nn=99 Recorder mode cancelled
    When nn is not entered, the Master recorder
    is selected.
    Live/Playback image CMD:RmmVS ANS:RmmVSn Necessary when using a non-Panasonic
    recorder with the Multiplexer board. 
    Transmission command changes the monitor
    display between live and playback image.
    n=0 Live image
    n=1 Playback image 
    						
    							158
    Available only with the Multiplexer board
    Transmission command toggles still display
    ON or OFF.
    mm=Monitor No.
    cc=Camera No.
    (cc=00 when toggling multiscreen still ON or
    OFF)
    n=0 OFF
    n=1 ON
    mm=Monitor No. FF ItemTransmission Command
    (ASCII)Response (ASCII) Parameter (ASCII)
    CMD:RmmFF ANS:RmmFF
    REW CMD:RmmRW ANS:RmmRW mm=Monitor No.
    Forward field advance CMD:RmmFA ANS:RmmFA mm=Monitor No.
    Backward field advance CMD:RmmRA ANS:RmmRA mm=Monitor No.
    Record CMD:RmmRC ANS:RmmRC mm=Monitor No.
    Index CMD:RmmSC ANS:RmmSC
    Still display CMD:RmmSTcc ANS:RmmSTccn
    Search editing area CMD:RmmTMn ANS:RmmTMn Available only for Record List and
    Thumbnail Display of WJ-HD500 Series
    Transmission command toggles search edit-
    ing area ON/OFF, or starts search.
    mm=Monitor No.
    n=0 OFF 
    n=1 ON
    n=2 Search startmm=Monitor No.
    Transmission command changes the monitor
    display between index and live image.
    Setup control commands (refer to p. 154) are
    available while the index is displayed.
    Group select CMD:RmmTG ANS:RmmTG Available only for Record List and
    Thumbnail Display of WJ-HD500 Series
    Transmission command selects group to be
    displayed.
    mm=Monitor No.
    Alarm search CMD:RmmAS ANS:RmmAS Available only for Record List and
    Thumbnail Display of WJ-HD500 Series
    Transmission command toggles alarm search
    ON or OFF.
    mm=Monitor No. 
    						
    							159
    Alarm historyItemTransmission Command
    (ASCII)Response (ASCII) Parameter (ASCII)
    Model  No QID qid:WJ-SX150A Matrix switchers model  No.
    Software version QRV qrv:*.**
    /*.**
    /*.**
    /*.**
    /*.**
    /*.**qrv:*.**=Unit firmware version
    /*.**= Master unit’s Multiplexer-board
    firmware version
    /*.**= Slave 1 unit’s Multiplexer-board
    firmware version
    /*.**= Slave 2 unit’s Multiplexer-board
    firmware version
    /*.**= Slave 3 unit’s Multiplexer-board
    firmware version
    /*.**= Slave 4 unit’s Multiplexer-board
    firmware version
    Inquiry
    Video loss historyQAD
    QVDqad:nnn:YYYYMMDD
    hhmmss:cc:ee:s
    qvd:nnn: YYYYMMDD
    hhmmss:cc:ee:snnn=alarm-event total number
    (000 to 100)
    *=Event of  alarm n (n is a number).
    Display pattern:
    YYYYMMDDhhmmss:cc:ee:s
    YYYY=Year
    MM=Month
    DD=Day
    hh=Hour
    mm= Month
    ss=Second
    cc=Alarm number (associated with the cam-
    era number: 00 when the alarm is suspended)
    ee= Event
    00=ALARM
    01=ACK
    02=RESET
    03=ALARM SUSPEND
    s=Daylight saving time
    0=OFF
    1=ON
    nnn=video-loss total number
    (000 to 100)
    *=Event of video loss n (n is a number).
    Display pattern:
    YYYYMMDDhhmmss:cc:ee:s
    YYYY=Year
    MM=Month
    DD=Day
    hh=Hour
    mm= Month
    ss=Second
    cc=Video loss number (associated with the
    camera number: 00  in case of  camera
    switching pulse loss/recovery)
    ee= Event
    00=Video loss
    01=Video loss recovery
    02=Camera switching loss
    03=Camera switching recovery
    04=SLAVE DOWN
    05=SLAVE RECOVER
    s=Daylight saving time
    0=OFF  1=ON 
    						
    							160
    Alarm display–ALM:cc:a:yyyymmdd:hhmm
    ss:ba=Event
    0=ALARM
    1=ACK
    2=RESET
    yyyy=Year
    mm=Month
    dd=Day
    hh=Hour
    ss=Second
    b=Daylight saving time
    0=OFF
    1=ON ItemTransmission Command
    (ASCII)Response (ASCII) Parameter (ASCII)
    Miscellaneous Control 
    						
    							161
    ■Error Code List
    Error code(ASCII) Error type Meaning
    ER000 No error There is no error.
    ER001 No associated command There is no associated command.
    ER002 Parameter invalid The parameters number, digit and range are invalid. 
    ER003 Receiver buffers overflow The receiver buffer has reached overflow capacity.
    ER301 Command invalid Invalid operation mode caused the command error.
    ER302 Parameter invalid The parameters number, digit and range are valid, but the operation mode
    is invalid.
    ER303 Gateway reception overflow Reception buffer overflow has occurred on the other device during the
    gateway communication.
    ER305 Gateway timeout error Timeout error has occurred during the gateway communication.
    ER309 Internal error The internal processing error has happened.
    Example:  The command is valid but it cannot be executed.
    (1)  The unit receives the zoom command while selecting a camera without electronic zoom function. 
    Transmission Command (ASCII)[STX] CMD:R01ZM [ETX]
    Transmission Command (ASCII)[STX] ANS:R01ZM:ER301 [ETX]
    ●Matrix switcher and external devices 
    						
    							162
    WORKSHEETS
    Gathering information for the initial configuration and recording on the following worksheets are recommended. Then, if set-
    tings need to be modified or updated later because of a change in surveillance needs or changes made in the systems com-
    ponents, those worksheets can be used to track revisions to your system.
    You should keep  all revised worksheets. Be sure to date them, in preparation for new entry or troubleshooting. Regardless of
    the system size, the worksheets can track past, current, and future configurations.
    ■Instruction
    Each worksheets title is the same as that of WJ-SX150A Administrator Console.
    For example, the Operator Registration worksheet supports the Operator Registration window.
    The worksheets rows, columns, and fields are arranged to match WJ-SX150A Administrator Console configuration require-
    ments.
    1. Reproduce the worksheets. You may need  dozens of copies.
    2. Reproduce instructions for the configuration windows . You can attach the portions of instructions to the worksheets.
    To keep record of the initial configuration of the system, date the Data Completed line on the top left of each sheet. 
    						
    							163
    ■Checklist
    It is recommended that the worksheets be completed in the following sequence:
    Date completed: ___/ ___/ ___
    ●Master-Slave 
    ●Logical Camera Number 
    Camera LCN
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    Master ON
    Slave 1 ON/OFF
    Slave 2 ON/OFF
    Slave 3 ON/OFF
    Slave 4 ON/OFF
    Master and Slave 1
    Camera Slave 1LCN
    Master
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    Normal connection (one unit only)
    Master, Slave 1 and Slave 2
    Camera Slave 1LCN
    Slave 2Master
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16 
    						
    							164
    Master and Slave 1 to 3
    Camera Slave 1LCN
    Slave 2Slave 3Master
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    Master and Slave 1 to 4
    Camera Slave 1LCN
    Slave 2Slave 3 Slave 4
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16 
    						
    All Panasonic manuals Comments (0)