    							74
    SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to
    configure the parameters.
    * In normal connection, only MASTER is displayed.
    CAM:This stands for a camera channel of the unit.
    LCN:This stands for a logical camera number. 1 to 99 is
    selectable.
    COMP:This stands for cable compensation. Select the
    desired setting according to the cable length.
    S:Less than 400 m (1 300 ft)
    M:400 m (1 300 ft) to 700 m (2 300 ft)
    L:700 m (2 300 ft) to 900 m (3 000 ft)
    Refer to p. 36 for available cables.
    The factory default setting is S.
    VD2:To send the VD2 timing pulse with the camera output
    signal, select ON. Not to send the VD2 timing pulse with
    the camera output signal, select OFF. The factory
    default setting is ON.
    DATA:To send the control data with the camera output sig-
    nal, select ON. Not to send the control data with the
    camera output signal, select OFF. The factory default
    setting is ON.
    *The available camera numbers will differ depending on
    the total number of matrix switchers.
    Notes:
    •When moving the joystick to ▼at the bottom of COM-
    PENSATION/VD2/DATA, the monitor will display 2 of 2.
    •When moving the joystick to ▲at the bottom of COM-
    PENSATION/VD2/DATA, the monitor will display 1 of 2.
    •Camera channels of the Master unit which connect
    Slave units are displayed as a space. You cannot con-
    figure the parameters.
    • CAMERA/DATA1 – 4 PORT
    This menu links to the submenu.
    Move the cursor and press the CAM (SET) button to go into
    the menu.
    740 CAMERA/DATA1-4 PORT will appear on the monitor.
    Setting for normal connection 
     740 CAMERA/DATA1-4 PORT
      SWITCHER=SLAVE1(1 of 5)
         PORT      MODE           SPEED
         CAMERA    CAMERA         19200bps
         DATA1     CAMERA         19200bps
         DATA2     CAMERA         19200bps
         DATA3     CAMERA         19200bps
         DATA4     MASTER-SLAVE   38400bps
         HDR       HDR             9600bps
         SERIAL    --             38400bps
    When Master, Slave 1 to 3 are connected
    CAM12345678910111213141516
    Slave 112345678910111213141516
    Slave 2 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
    Slave 3 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
    Master - - - - - - - - - - - - - - - - - - - - - - - - 49 50 51 52
    CAM12345678910111213141516
    Slave 112345678910111213141516
    Slave 2 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
    Slave 3 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
    Slave 4 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64
    Master - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
    When Master, Slave 1 to 4 are connected
    Notes:
    •When you select logical camera numbers, the setting
    will be automatically activated in other menus.
    •Camera channels of the Master unit which connect
    Slave units are displayed as a space. You cannot con-
    figure the parameters.
    •You can select a logical camera number for only one
    channel. When you enter the same number second
    time, the newer is activated, but the older will be
    changed to a space.
    • COMPENSATION/VD2/DATA
    This menu links to the submenu.
    Move the cursor and press the CAM (SET) button to go into
    the menu.
    730 COMPENSATION/VD2/DATA will appear on the moni-
    tor.
     730 COMPENSATION/VD2/DATA         1 of 2
      SWITCHER=SLAVE1(1 of 4)
          CAM  LCN  COMP  VD2  DATA
            1    1  S     ON   ON
            2    2  S     ON   ON
            3    3  S     ON   ON
            4    4  S     ON   ON
            5    5  S     ON   ON
            6    6  S     ON   ON
            7    7  S     ON   ON
            8    8  S     ON   ON
             LCN:LOGICAL CAMERA NUMBER
     730 COMPENSATION/VD2/DATA         2 of 2
      SWITCHER=SLAVE1(1 of 4)
          CAM  LCN  COMP  VD2  DATA
            9    9  S     ON   ON
           10   10  S     ON   ON
           11   11  S     ON   ON
           12   12  S     ON   ON
           13   13  S     ON   ON
           14   14  S     ON   ON
           15   15  S     ON   ON
           16   16  S     ON   ON
             LCN:LOGICAL CAMERA NUMBER
     740 CAMERA/DATA1-4 PORT
      SWITCHER=MASTER(1 of 1)
         PORT      MODE           SPEED
         CAMERA    CAMERA         19200bps
         DATA1     TERMINAL-K1     9600bps
         DATA2     TERMINAL-K2     9600bps
         DATA3     TERMINAL-K3     9600bps
         DATA4     PS-DATA         9600bps
         HDR       HDR             9600bps
         SERIAL    PC             38400bps 
    						
    							75
    Port 740 CAMERA/DATA1-4 PORT
      SWITCHER=MASTER(5 of 5)
         PORT      MODE           SPEED
         CAMERA    TERMINAL-K1     9600bps
         DATA1     TERMINAL-K2     9600bps
         DATA2     TERMINAL-K3     9600bps
         DATA3     MASTER-SLAVE   38400bps
         DATA4     PS-DATA         9600bps
         HDR       HDR             9600bps
         SERIAL    PC             38400bps
    Master unit setting for Master-Slave connection 
    Slave unit setting for Master-Slave connection 
    SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to
    configure the parameters.
    * In normal connection, only MASTER is displayed.
    The factory default setting is same as the illustration.
    PORT:This stands for the type of a port.
    CAMERA:RS-485 Camera port
    DATA 1/2/3/4:DATA 1/2/3/4 ports
    HDR:DATA HDR port
    SERIAL:SERIAL port
    MODE:This stands for the operation mode of a port.
    CAMERA:Select this if a camera is connected.
    TERMINAL-K1/K2/K3/K4:Select this if a terminal-mode
    system controller is connected.
    PS·DATA:Select this if a PS·DATA system controller is
    connected.
    MASTER-SLAVE:The port used for the master-slave
    connection is fixed to this parameter.
    HDR:The HDR port is fixed to this parameter.
    PC:WJ-SX150A Administrator Console configuration
    and firmware update becomes available with a PC
    connection.
    VCR:Select this if a time-lapse VCR (Panasonic model)
    is connected.
    – – –:This port is unusable.
    The following are MODE parameters assigned to
    each port.
     740 CAMERA/DATA1-4 PORT
      SWITCHER=SLAVE1(1 of 5)
         PORT      MODE           SPEED
         CAMERA    CAMERA         19200bps
         DATA1     CAMERA         19200bps
         DATA2     CAMERA         19200bps
         DATA3     CAMERA         19200bps
         DATA4     MASTER-SLAVE   38400bps
         HDR       HDR             9600bps
         SERIAL    --             38400bps
    The factory default setting is same as the illustration.
    SPEED:This stands for the communication speed of a port.
    38400 bps*:Select this to set the speed to 38400 bps.
    19200 bps:Select this to set the speed to 19200 bps.
    9600 bps:Select this to set the speed to 9600 bps.
    4800 bps:Select this to set the speed to 4800 bps.
    * This parameter is available only for SERIAL.
    The factory default setting is same as the illustration.
    Notes:
    •If the DATA 4 is set to PS·DATA, SPEED of PS·DATA will
    be changed in conjunction with that of HDR.
    •When you change MODE, the default communication
    speed is automatically set. The SERIAL port is set to the
    default speed when CONTROL is changed in 600
    RECORDER. (Refer to p. 71.)
    The default communication speeds are shown in the dia-
    gram.
    MODE Factory default setting
    CAMERA 19200 bps
    TERMINAL 9600 bps
    PS·DATA 9600 bps
    HDR 9600 bps
    PC 38400 bps
    VCR (VTR) 9600 bps
    CAMERA
    DATA 1
    DATA 2
    DATA 3
    DATA 4
    HDR
    SERIALMaster
    Normal connection
    CAMERA
    TERMINAL-K1/K2/
    K3/K4
    CAMERA
    TERMINAL-K1/K2/
    K3/K4
    CAMERA
    TERMINAL-K1/K2/
    K3/K4
    CAMERA
    TERMINAL-K1/K2/
    K3/K4
    PS
    ·DATA
    HDR
    PC
    Master-slave connection
    TERMINAL-K1/K2/
    K3/K4
    CAMERA
    TERMINAL-K1/K2/
    K3/K4
    CAMERA
    TERMINAL-K1/K2/
    K3/K4
    CAMERA
    MASTER-SLAVE
    TERMINAL-K1/K2/
    K3/K4
    PS
    ·DATA
    HDR
    PCSlave 1
    to 4
    CAMERA
    CAMERA
    CAMERA
    CAMERA
    MASTER-
    SLAVE
    HDR
    – – –
    VCR VCR VCR 
    						
    							76
    • RS485 CAMERA
    This menu links to the submenu.
    Move the cursor and press the CAM (SET) button to go into
    the menu. 750 RS485 CAMERA will appear on the monitor.
    SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*)
    to configure the parameters.
    * In normal connection, only MASTER is displayed.
    CAM:This stands for a camera channel of the unit.
    LCN:This stands for a logical camera number.
    PORT:This stands for a port which connects the cam-
    era.
    RS485:Select this when the camera is connected
    to the RS-485 camera port.
    DATA1/2/3:Select this when the camera is con-
    nected to the DATA 1/2/3 port.
    You can select the parameters only for the ports whose
    mode is set to “CAMERA” in 740 CAMERA/DATA1-4 PORT.
    (Refer to pp.74 and 75.) If the mode is set to others, a
    space will be displayed for PORT.
    Notes: 
    •If five (Master and Slave 1 to 4) units are connected in
    the system, you can configure no parameters for MAS-
    TER.
    •If the mode is changed to “TERMINAL-K1/2/3/4” in 740
    CAMERA/DATA1-4 PORT, the PORT parameters will be
    deactivated even after set to RS485 or DATA1/2/3.
    • CAMERA CLEANING
    ON:Activates the manual cleaning for the cameras.
    OFF:Deactivates the manual cleaning.
    When you set CAMERA CLEANING to ON and exit from the
    SETUP MENU, camera cleaning will start.
    The factory default setting is OFF.
    Notes:
    •When the camera cleaning is active, cleaning will begin
    from CAM 1 in numerical order.
    •Surveillance is impossible during the cleaning.
    •The cleaning cannot be stopped after it is started.
    •Refer to pp. 37 and 38 for details on RS-485 connec-
    tions.
    •The camera address needs to be corresponding with
    the camera number.
    ■OPERATOR REGISTRATION
    ●How to Display
    To display this menu on the monitor, move the cursor to
    800 OPERATOR REGISTRATION in SETUP MENU by mov-
    ing the joystick to ▼.Then, press the CAM (SET) button. The
    submenu appears on the monitor.
    ●Parameters
    Move the joystick to move the cursor.
    Press the NEXT or PREV button to select the desired para-
    meters.
    Press the numeric button(s) to enter a number.
    • OPERATOR NO.
    This stands for an operator number. When you enter the
    number by pressing the NEXT, PREV or numeric button(s),
    this menu will display the associated operators information.
    1 to 16 is available.
    • ID
    This stands for an operator ID. 1 to 99999 is available.
    • PASSWORD
    This stands for an operators password. 1 to 99999 is avail-
    able. The password will be displayed as ∗∗∗∗∗ on the
    monitor.
    • PRIORITY
    This stands for an operators priority. 1 to 16 is available.
    (Refer to p. 15 for details on Priority Lock.)
    • LEVEL
    This stands for an operators restrict level. It is configurable
    through Level Table (refer to p. 91) of WJ-SX150A
    Administrator Console what kind of restriction is given to the
    operator. 1 to 3 is available. 
    SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*)
    to configure the parameters.
    * In normal connection, only MASTER is displayed.
    CAM:This stands for a camera channel of the unit.
    LCN:This stands for a logical camera number. 1 to 99
    is selectable. 
     750 RS485 CAMERA
      SWITCHER=SLAVE1(1 of 5)
      CAM LCN PORT        CAM LCN PORT
        1  21               9  51
        2  22              10  52
        3  23              11  53
        4  24              12  54
        5  25              13  55
        6  26              14  56
        7  27              15  57
        8  28              16  58
          LCN:LOGICAL CAMERA NUMBER
     800 OPERATOR REGISTRATION
     OPERATOR NO.=1
      ID         =150     PRIORITY= 1
      PASSWORD   =∗∗∗∗∗     LEVEL   = 1
      SWITCHER=SLAVE(1 of 5)
     CAM LCN             CAM LCN
       1  21 VIEW&CONTROL  9  51 VIEW&CONTROL
       2  22 VIEW ONLY    10  52 VIEW&CONTROL
       3  23 VIEW&CONTROL 11  53 VIEW ONLY
       4  24 VIEW ONLY    12  54 VIEW&CONTROL
       5  25 VIEW&CONTROL 13  55 VIEW&CONTROL
       6  26 VIEW&CONTROL 14  56 VIEW&CONTROL
       7  27 VIEW&CONTROL 15  57 PROHIBITED
       8  28 VIEW&CONTROL 16  58 PROHIBITED 
    						
    							77
    ■MULTIPLEXER
    ●How to Display
    To display this menu on the monitor, move the cursor to 900
    MULTIPLEXER in SETUP MENU by moving the joystick to
    Dor C. Then, press the CAM (SET) button. The submenu
    appears on the monitor.
    ●Parameters
    Move the joystick to move the cursor.
    Press the NEXT or PREV button to select the desired para-
    meters.
    SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to
    configure the parameters.
    * In normal connection, only MASTER is displayed.
    Ver. ∗. ∗∗:Firmware version of a Multiplexer board
    • ALARM
    EXT.:Select this to gen-lock the unit with the recorder
    when an alarm is input to the unit.
    002,004 to 128 (field):Select one of these alarm
    recording rates if the asynchronous unit is connect-
    ed to the unit.
    The factory default setting is EXT.
    MUX• CAM 01 to 16:
    These stand for an operators camera operation coverage.
    The following are the parameters.
    VIEW & CONTROL:The operator can display the cam-
    era image on the monitor and control panning/tilt-
    ing.
    VIEW ONLY:The operator can display the camera
    image on the monitor, but cannot control the pan-
    ning/tilting.
    PROHIBITED:The operator can neither display the
    camera image on the monitor nor control the pan-
    ning/tilting.
    The following is the factory default setting of this menu.
    Note:When you enter an invalid number, the parameter will
    return to the state before your numerical entry.
    6 OPERATOR NO. ID PASSWORD LEVEL PRIORITY
    1150 150 1 1
    2112345 1 2
    3100 100 1 3
    4101 101 1 4
    5102 102 2 5
    6103103 3
    CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to
    6)
     900 MULTIPLEXER
      SWITCHER=SLAVE1(1 of 5)        Ver.∗.∗∗
         VCR REC MODE
     910         ALARM     EXT.
     920         NORMAL    EXT.
     930 DYNAMIC REC       OFF
     940 DUMMY BLACK       ON
     950 CAM SW LOSS       ON
     900 MULTIPLEXER
      SWITCHER=MASTER(5 of 5)        Ver.∗.∗∗
         VCR REC MODE
     910         ALARM     ---
     920         NORMAL    ---
     930 DYNAMIC REC       ---
     940 DUMMY BLACK       ---
     950 CAM SW LOSS       --- 
    						
    							78
    • NORMAL
    EXT.:Select this to gen-lock the unit during the normal
    operation.
    002,004 to 255 (field):Select one of these normal
    recording rates if the asynchronous unit is connect-
    ed to the unit. 
    The factory default setting is EXT.
    • DYNAMIC REC
    PRI.:Select this to give recording priority to the camera
    channel with the alarm input.
    ONLY:Select this to record the images from the alarm-
    associated camera channel.
    GROUP:Select this to give recording priority to a group
    of up to 4 camera channels associated to the alarm
    input.
    OFF:Select this to deactivate the alarm priority mode.
    The factory default setting is OFF.
    • DUMMY BLACK
    ON:Select this to display the black picture for a camera
    channel that is not connected to the camera.
    OFF:Select this to skip the camera channels that are
    not connected to the camera in the sequence/spot
    mode.
    The factory default setting is ON.
    • CAM SW LOSS
    ON:Select this to make “CAMSW LOSS R∗” light up on
    the associated monitor when loss of the camera
    switching pulse is detected.
    OFF:Select this not to make “CAMSW LOSS R∗”
    appear on the associated monitor when loss of the
    camera switching pulse is detected.
    The factory default setting is ON.
    Note:If EXT. is selected for 910 ALARM/920 NORMAL,
    the playback images cannot be displayed on the
    monitors which are not connected to the EXT IN
    connector. Confirm the images on those which are
    connected to the recorder.
    ■MUX CAMERA TITLE
    ●How to Display
    To display this menu on the monitor, move the cursor to
    1000 MUX CAMERA TITLE in SETUP MENU by moving the
    joystick to Dor C. Then, press the CAM (SET) button. The
    submenu appears on the monitor.
    ●How to edit
    The factory default settings are same as the illustration.
    The editing procedure is the same as 500 CAMERA TITLE.
    (Refer to p. 71.)
    Notes:
    •Up to 8 alphanumeric characters are available for
    each Multiplexer board camera title.
    •When moving the joystick to Dat the last text box
    of CAM 8 TITLE, the cursor will move to the first text
    box of CAM 9 TITLE.
    •When moving the joystick to Cat the first text box
    of CAM 9 TITLE, the cursor will move to the last text
    box of CAM 8 TITLE.
    •If five units are connected in the system, you can
    configure no parameters for MASTER.
    MUX
     1000 MUX CAMERA TITLE
      SWITCHER=SLAVE1(1 of 3)
      CAM LCN TITLE       CAM LCN TITLE
        1   1 C01           9  09 C09
        2   2 C02          10  10 C10
        3   3 C03          11  11 C11
        4   4 C04          12  12 C12
        5   5 C05          13  13 C13
        6   6 C06          14  14 C14
        7   7 C07          15  15 C15
        8   8 C08          16  16 C16
        LCN:LOGICAL CAMERA NUMBER 
    						
    							79
    Trademarks
    •IBM is a trademark of International Business Machines
    Corporation.
    •Intel and Pentium are trademarks of Intel Corporation.
    •Microsoft
    ® Windows®are either registered trademarks
    of Microsoft Corporation in the United States and/or
    other countries.
    •VD2 is the original synchronization system of
    Matsushita Electric Industrial Co., Ltd.
    •Other company names and product names appearing
    in the manual are registered trademarks or trademarks
    of the company concerned.
    Platform
    To install WJ-SX150A Administrator Console, the PC should
    meet the following requirements.
    •Hardware requirements
    IBM PC or 100 % compatible, Pentium 3- equivalent
    or higher, 128 MB RAM, 5 MB hard drive space with
    additional space for configuration database (.sdt) and
    log.
    In addition, the PC must be equipped with a serial port.
    •Operating system requirements
    Microsoft
    ®Windows®98, 98 SE, 2000, XP Professional
    •Video display setting requirements
    *High color (16 bit) or higher
    *800 x 600 resolution
    When installing in the default system setting, the software is
    installed in the following directory:
    C: \Program Files\Panasonic\SX150A
    ■Installation/Uninstallation
    ●Installation
    Insert the CD-ROM program disk into the CD-ROM drive on
    the PC. The file is located in the following directory.
    E: \Admin\Setup.exe
    Double-click Setup.exe to begin the installation.  Respond
    to the dialog boxes by following the directions given.
    ●Uninstallation
    1. Select Start – Settings – Control Panel.
    2. Click on the Add/Remove Hardware button.
    3. Select WJ-SX150A Administrator Console and click on
    Add/Remove.
    4. Operate according to the direction in the window.
    ■Description of WJ-SX150A
    Administrator Console
    WJ-SX150A Administrator Console is a utility software
    which can configure the system settings and control data of
    this surveillance system.
    WJ-SX150A Administrator Console can configure the follow-
    ing settings.
    ●MASTER-SLAVE
    •Master-Slave (p. 81)
    •Logical Camera Number (p. 82)
    ●MANAGEMENT
    •Put a file to SX150A (p. 83)
    •Get a Configuration Data from SX150A (p. 83)
    ●SETUP
    Sequence Settings
    •Tour Sequence (p. 84)
    •Group Sequence (p. 85)
    Schedule Settings
    •Timer Event (p. 85)
    •Camera Cleaning (p. 86)
    •Daylight Saving Time/Summer Time (p. 87)
    Alarm Settings
    •Alarm Mode (p. 88)
    •Alarm Event (p. 89)
    •Alarm Port (p. 90)
    Operator Settings
    •Operator Registration (p. 90)
    •Level Table (p. 91)
    •Monitor Selection (p. 92)
    •Auto Login/Logout (Auto Log-in/Log-out) (p. 92)
    System Settings
    •Time & Date (p. 93)
    •Cable Compensation/VD2/DATA (p. 94)
    •Camera Title (p. 94)
    •Data Port (p. 96)
    •Recorder (p. 97)
    •Multiplexer Mode (p. 98) 
    •Multiplexer Title (p. 100) 
    WJ-SX150A Administrator Console
    •New (p. 101)
    •Select Setup Data File (p. 101)
    •Account Manager (p. 101)
    •Communication Port (p. 102)
    MUX
    MUX
    WJ-SX150A ADMINISTRATOR CONSOLE 
    						
    							80
    3. When terminating the software, click on the EXIT button
    or press the ESC button on the PC keyboard. The main
    window will close and WJ-SX150A Administrator
    Console will be terminated.
    Note: The operator name and password are changeable.
    Operator addition is also available. The configuration of
    each operator name, password and level are neces-
    sary. (Refer to p. 101 Account Manager.)
    ■The Main Window
    This window appears when starting up WJ-SX150A
    Administrator Console.
    Clicking on each button in the window will display the asso-
    ciated configuration window.
    Refer to the description of each window for details.
    ●Before Using WJ-SX150A
    Administrator Console
    1. Select Start – Program – Panasonic – WJ-SX150A
    Administrator Console x.xx* or double-click the WJ-
    SX150A Administrator Console x.x icon on the desktop.
    *x.xx is a version number.
    2. When you launch WJ-SX150A Administrator Console for
    the first time, the following window will appear on the
    PC screen.
    Select “Yes”.
    →The selection will be memorized to WJ-SX150A
    Administrator Console while launching it.
    Note:To change the selection you have done in the
    Startup Menu window, restart the WJ-SX150A
    Administrator Console while holding down the SHIFT
    key on the PC keyboard.
    ●Startup/Termination
    1. Select Start – Program – Panasonic – WJ-SX150A
    Administrator Console x.xx* or double-click the WJ-
    SX150A Administrator Console x.x icon on the desktop.
    *x.x: Software version
    →The User ID and Password Required window will
    appear on the PC screen.
    2. Enter admin and sx150 in the boxes Name and
    Password respectively.
    Then, click on the OK button.
    →WJ-SX150A Administrator Console starts up and the
    main window will appear on the PC screen.
    EXIT button
    Minimizing button 
    						
    							81
    (Multiplexer Mode): 
    Multiplexer Mode window (p. 98)
    (Multiplexer Title): 
    Multiplexer Title window (p. 100)
    In addition, the main window has the following buttons.
    (New):
    New window (p. 101)
    (File Open):
    Select Setup Data File window (p. 101)
    (Account Manager):
    Account Manager window (p. 101)
    (Communication Port):
    Communication Port window (p. 102)
    (Panasonic):
    Opens the version information window of WJ-
    SX150A Administrator Console. Clicking on OK
    button will close the window.
    Note:To reflect each configuration to the system, save the
    file by pressing the SAVE button before closing the win-
    dow. After that, be sure to put the file from the PC to the
    unit.
    ■Master-Slave
    This window configures the composition of master-slave
    connection. Recorders selected in the Recorder window (p.
    97) are activated/deactivated in the Master-Slave window.
    ●How to Display
    To display this window, click on the  (Master-Slave)
    button in the main window (p. 80).
    ●How to Display
    • Master
    The Master unit and the connected recorder are displayed.
    MUX
    MUXMASTER-SLAVE
    (Master-Slave):
    Master-Slave window (p. 81)
    (Logical Camera Number)
    Logical Camera Number window (p. 82)
    MANAGEMENT
    (Put to SX150A):
    Put a file to SX150A window (p. 83)
    (Get from SX150A):
    Get a Configuration Data from SX150A window
    (p. 83)
    SEQUENCE
    (Tour Sequence):  Tour Sequence window
    (p. 84)
    (Group Sequence):Group Sequence window
    (p. 85)
    SCHEDULE
    (Timer Event):
    Timer Event window (p. 85)
    (Camera Cleaning):
    Camera Cleaning window (p. 86)
    (Daylight Saving Time/Summer Time):
    Daylight Saving Time/Summer Time window
    (p. 87)
    ALARM
    (Alarm Mode):
    Alarm Mode window (p. 88)
    (Alarm Event):
    Alarm Event window (p. 89)
    (Alarm Port):
    Alarm Port window (p. 90)
    OPERATOR
    (Operator Registration):
    Operator Registration window (p. 90)
    (Level Table):
    Level Table window (p. 91)
    (Monitor Selection):
    Monitor Selection window (p. 92)
    (Auto Login/Logout):
    Auto Login/Logout window (p. 92)
    SYSTEM
    (Time & Date):
    Time & Date window (p. 93)
    (Cable Compensation/VD2/DATA):
    Cable Compensation/VD2/DATA window (p. 94)
    (Camera Title):
    Camera Title window (p. 94)
    (Data Port):
    Data Port window (p. 96)
    (Recorder Control): 
    Recorder window (p. 97) 
    						
    							82
    • Slave
    Slave units and connected recorders are displayed. To
    activate/deactivate Slave units, click the ON/OFF button of
    a desired Slave unit. When Slave units are set to ON, their
    unit names become selectable in SETUP MENU to config-
    ure the parameters. 
    (Save Exit) button
    Saves the configuration and closes the Master-Slave win-
    dow.
    (Cancel Exit) button
    Cancels the configuration and closes the Master-Slave win-
    dow.
    Notes:
    •If you configure the master-slave composition, settings
    concerning LCN (logical camera number) and
    Multiplexer Title (refer to p. 100) will be changed. When
    you click on the Save Exit button, a message window
    will appear to confirm you the change.
    •In WJ-SX150A Administrator Console, camera channels
    of the Master unit which are connected to MONITOR
    OUT 1/2/3/4 of Slave units are displayed in gray. You
    cannot configure the parameters.
    ■Logical Camera Number
    This window configures logical camera numbers assigned
    to camera channels of each unit. During operation, logical
    camera numbers are used for camera control and monitor
    display.
    To display this window, click on the  (Logical Camera
    Number) button in the main window (p. 80).
    ●How to Display
    • CAM 1 to 16
    This stands for a camera channel of the unit.
    • Logical Camera Number
    Click on each drop-down menu to select a desired logical
    camera number. 1 to 99 is selectable. For camera channels
    without camera connections, select “- -“.
    (Save Exit) button
    Saves the configuration and closes the Logical Camera
    Number window.
    (Cancel Exit) button
    Cancels the configuration and closes the Logical Camera
    Number window.
    Notes:
    •If logical camera numbers are not selected, the cam-
    eras’ LCNs are not displayed in each window of SETUP
    MENU and WJ-SX150A Administrator Console.
    •You can select a logical camera number for only one
    channel. When you select the same number more than
    one time, a message will appear. The message will noti-
    fy you that the number has been already used. If you
    click on “Yes”, the newer will be activated and the older
    will be changed to “- -“. If you click on “No”, the
    changed parameters will return to the former state.
    •If five units (Master and Slave 1 to 5) are connected in
    the system, you cannot select logical camera numbers
    for Master. 
    						
    							83
    ■Put a file to SX150A
    Pressing this button will start the putting of the configuration
    file from the PC to the unit.
    ●How to Display
    To display this window, click on the  (Put to
    SX150A) button in the main window (p. 80).
    ●Parameters
    The file name of the configuration data appears.
    (OK) button
    To put the configuration file from the PC to the unit, click on
    this button.
    (Cancel Exit) button
    To cancel the putting of the configuration file from the PC to
    the unit, click on this button.
    Notes:
    •The setup file has been configured at the factory, and
    the file names appear on the main windows title bar.
    •Put the file from the PC to the unit when the time with no
    necessary to the continuous system operation, such as
    after-hours. After the file putting, the system will auto-
    matically restart. Then, the system controllers will tem-
    porarily log out.
    •To change a file, select a file again. (Refer to p. 101
    Select Setup Data File.)
    •The configuration file cannot be put to the unit while
    opening SETUP MENU.
    •It takes a few seconds to put a file to SX150A, and you
    might assume the PC has been freezing.
    Wait until the message “Completed!” appears on the
    screen. If the message “Connection error” appears, the
    PC is incorrectly connected to the unit. Confirm the set-
    tings of WJ-SX150A Administrator Console and retry the
    file putting.
    (Refer to p. 74 CAMERA/DATA 1-4 PORT and p. 102
    Communication Port.)
    ■Get a Configuration Data from
    SX150A
    Pressing this button will start the getting of the configuration
    data from the unit to the PC.
    ●How to Display
    To display this window, click on the  (Get from
    SX150A) button in the main window (p. 80).
    ●Parameters
    The file name of the configuration data appears.
    (OK) button
    To get the configuration data from the unit to the PC, click
    on this button.
    (Cancel Exit) button
    To cancel the getting of the configuration data from the unit
    to the PC, click on this button.
    Notes: 
    •The configuration data getting is also possible during
    the surveillance, for it will not interfere with the system
    operation.
    •The past data will be overwritten when getting a new
    configuration data.
    •To change the getting directory, select it. (Refer to p.
    101 Select Setup Data File.)
    •When the file getting has been successfully executed,
    “Completed!” will appear. If “Connection Error”
    appears, confirm the connection and the serial port set-
    ting of the PC and the unit. (Refer to p. 74
    CAMERA/DATA 1-4 PORT and p. 102 Communication
    Port.) If “Failed!” appear, retry the file getting. 
    						