74 SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters. * In normal connection, only MASTER is displayed. CAM:This stands for a camera channel of the unit. LCN:This stands for a logical camera number. 1 to 99 is selectable. COMP:This stands for cable compensation. Select the desired setting according to the cable length. S:Less than 400 m (1 300 ft) M:400 m (1 300 ft) to 700 m (2 300 ft) L:700 m (2 300 ft) to 900 m (3 000 ft) Refer to p. 36 for available cables. The factory default setting is S. VD2:To send the VD2 timing pulse with the camera output signal, select ON. Not to send the VD2 timing pulse with the camera output signal, select OFF. The factory default setting is ON. DATA:To send the control data with the camera output sig- nal, select ON. Not to send the control data with the camera output signal, select OFF. The factory default setting is ON. *The available camera numbers will differ depending on the total number of matrix switchers. Notes: •When moving the joystick to ▼at the bottom of COM- PENSATION/VD2/DATA, the monitor will display 2 of 2. •When moving the joystick to ▲at the bottom of COM- PENSATION/VD2/DATA, the monitor will display 1 of 2. •Camera channels of the Master unit which connect Slave units are displayed as a space. You cannot con- figure the parameters. • CAMERA/DATA1 – 4 PORT This menu links to the submenu. Move the cursor and press the CAM (SET) button to go into the menu. 740 CAMERA/DATA1-4 PORT will appear on the monitor. Setting for normal connection 740 CAMERA/DATA1-4 PORT SWITCHER=SLAVE1(1 of 5) PORT MODE SPEED CAMERA CAMERA 19200bps DATA1 CAMERA 19200bps DATA2 CAMERA 19200bps DATA3 CAMERA 19200bps DATA4 MASTER-SLAVE 38400bps HDR HDR 9600bps SERIAL -- 38400bps When Master, Slave 1 to 3 are connected CAM12345678910111213141516 Slave 112345678910111213141516 Slave 2 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Slave 3 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Master - - - - - - - - - - - - - - - - - - - - - - - - 49 50 51 52 CAM12345678910111213141516 Slave 112345678910111213141516 Slave 2 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Slave 3 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Slave 4 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Master - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - When Master, Slave 1 to 4 are connected Notes: •When you select logical camera numbers, the setting will be automatically activated in other menus. •Camera channels of the Master unit which connect Slave units are displayed as a space. You cannot con- figure the parameters. •You can select a logical camera number for only one channel. When you enter the same number second time, the newer is activated, but the older will be changed to a space. • COMPENSATION/VD2/DATA This menu links to the submenu. Move the cursor and press the CAM (SET) button to go into the menu. 730 COMPENSATION/VD2/DATA will appear on the moni- tor. 730 COMPENSATION/VD2/DATA 1 of 2 SWITCHER=SLAVE1(1 of 4) CAM LCN COMP VD2 DATA 1 1 S ON ON 2 2 S ON ON 3 3 S ON ON 4 4 S ON ON 5 5 S ON ON 6 6 S ON ON 7 7 S ON ON 8 8 S ON ON LCN:LOGICAL CAMERA NUMBER 730 COMPENSATION/VD2/DATA 2 of 2 SWITCHER=SLAVE1(1 of 4) CAM LCN COMP VD2 DATA 9 9 S ON ON 10 10 S ON ON 11 11 S ON ON 12 12 S ON ON 13 13 S ON ON 14 14 S ON ON 15 15 S ON ON 16 16 S ON ON LCN:LOGICAL CAMERA NUMBER 740 CAMERA/DATA1-4 PORT SWITCHER=MASTER(1 of 1) PORT MODE SPEED CAMERA CAMERA 19200bps DATA1 TERMINAL-K1 9600bps DATA2 TERMINAL-K2 9600bps DATA3 TERMINAL-K3 9600bps DATA4 PS-DATA 9600bps HDR HDR 9600bps SERIAL PC 38400bps
75 Port 740 CAMERA/DATA1-4 PORT SWITCHER=MASTER(5 of 5) PORT MODE SPEED CAMERA TERMINAL-K1 9600bps DATA1 TERMINAL-K2 9600bps DATA2 TERMINAL-K3 9600bps DATA3 MASTER-SLAVE 38400bps DATA4 PS-DATA 9600bps HDR HDR 9600bps SERIAL PC 38400bps Master unit setting for Master-Slave connection Slave unit setting for Master-Slave connection SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters. * In normal connection, only MASTER is displayed. The factory default setting is same as the illustration. PORT:This stands for the type of a port. CAMERA:RS-485 Camera port DATA 1/2/3/4:DATA 1/2/3/4 ports HDR:DATA HDR port SERIAL:SERIAL port MODE:This stands for the operation mode of a port. CAMERA:Select this if a camera is connected. TERMINAL-K1/K2/K3/K4:Select this if a terminal-mode system controller is connected. PS·DATA:Select this if a PS·DATA system controller is connected. MASTER-SLAVE:The port used for the master-slave connection is fixed to this parameter. HDR:The HDR port is fixed to this parameter. PC:WJ-SX150A Administrator Console configuration and firmware update becomes available with a PC connection. VCR:Select this if a time-lapse VCR (Panasonic model) is connected. – – –:This port is unusable. The following are MODE parameters assigned to each port. 740 CAMERA/DATA1-4 PORT SWITCHER=SLAVE1(1 of 5) PORT MODE SPEED CAMERA CAMERA 19200bps DATA1 CAMERA 19200bps DATA2 CAMERA 19200bps DATA3 CAMERA 19200bps DATA4 MASTER-SLAVE 38400bps HDR HDR 9600bps SERIAL -- 38400bps The factory default setting is same as the illustration. SPEED:This stands for the communication speed of a port. 38400 bps*:Select this to set the speed to 38400 bps. 19200 bps:Select this to set the speed to 19200 bps. 9600 bps:Select this to set the speed to 9600 bps. 4800 bps:Select this to set the speed to 4800 bps. * This parameter is available only for SERIAL. The factory default setting is same as the illustration. Notes: •If the DATA 4 is set to PS·DATA, SPEED of PS·DATA will be changed in conjunction with that of HDR. •When you change MODE, the default communication speed is automatically set. The SERIAL port is set to the default speed when CONTROL is changed in 600 RECORDER. (Refer to p. 71.) The default communication speeds are shown in the dia- gram. MODE Factory default setting CAMERA 19200 bps TERMINAL 9600 bps PS·DATA 9600 bps HDR 9600 bps PC 38400 bps VCR (VTR) 9600 bps CAMERA DATA 1 DATA 2 DATA 3 DATA 4 HDR SERIALMaster Normal connection CAMERA TERMINAL-K1/K2/ K3/K4 CAMERA TERMINAL-K1/K2/ K3/K4 CAMERA TERMINAL-K1/K2/ K3/K4 CAMERA TERMINAL-K1/K2/ K3/K4 PS ·DATA HDR PC Master-slave connection TERMINAL-K1/K2/ K3/K4 CAMERA TERMINAL-K1/K2/ K3/K4 CAMERA TERMINAL-K1/K2/ K3/K4 CAMERA MASTER-SLAVE TERMINAL-K1/K2/ K3/K4 PS ·DATA HDR PCSlave 1 to 4 CAMERA CAMERA CAMERA CAMERA MASTER- SLAVE HDR – – – VCR VCR VCR
76 • RS485 CAMERA This menu links to the submenu. Move the cursor and press the CAM (SET) button to go into the menu. 750 RS485 CAMERA will appear on the monitor. SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters. * In normal connection, only MASTER is displayed. CAM:This stands for a camera channel of the unit. LCN:This stands for a logical camera number. PORT:This stands for a port which connects the cam- era. RS485:Select this when the camera is connected to the RS-485 camera port. DATA1/2/3:Select this when the camera is con- nected to the DATA 1/2/3 port. You can select the parameters only for the ports whose mode is set to “CAMERA” in 740 CAMERA/DATA1-4 PORT. (Refer to pp.74 and 75.) If the mode is set to others, a space will be displayed for PORT. Notes: •If five (Master and Slave 1 to 4) units are connected in the system, you can configure no parameters for MAS- TER. •If the mode is changed to “TERMINAL-K1/2/3/4” in 740 CAMERA/DATA1-4 PORT, the PORT parameters will be deactivated even after set to RS485 or DATA1/2/3. • CAMERA CLEANING ON:Activates the manual cleaning for the cameras. OFF:Deactivates the manual cleaning. When you set CAMERA CLEANING to ON and exit from the SETUP MENU, camera cleaning will start. The factory default setting is OFF. Notes: •When the camera cleaning is active, cleaning will begin from CAM 1 in numerical order. •Surveillance is impossible during the cleaning. •The cleaning cannot be stopped after it is started. •Refer to pp. 37 and 38 for details on RS-485 connec- tions. •The camera address needs to be corresponding with the camera number. ■OPERATOR REGISTRATION ●How to Display To display this menu on the monitor, move the cursor to 800 OPERATOR REGISTRATION in SETUP MENU by mov- ing the joystick to ▼.Then, press the CAM (SET) button. The submenu appears on the monitor. ●Parameters Move the joystick to move the cursor. Press the NEXT or PREV button to select the desired para- meters. Press the numeric button(s) to enter a number. • OPERATOR NO. This stands for an operator number. When you enter the number by pressing the NEXT, PREV or numeric button(s), this menu will display the associated operators information. 1 to 16 is available. • ID This stands for an operator ID. 1 to 99999 is available. • PASSWORD This stands for an operators password. 1 to 99999 is avail- able. The password will be displayed as ∗∗∗∗∗ on the monitor. • PRIORITY This stands for an operators priority. 1 to 16 is available. (Refer to p. 15 for details on Priority Lock.) • LEVEL This stands for an operators restrict level. It is configurable through Level Table (refer to p. 91) of WJ-SX150A Administrator Console what kind of restriction is given to the operator. 1 to 3 is available. SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters. * In normal connection, only MASTER is displayed. CAM:This stands for a camera channel of the unit. LCN:This stands for a logical camera number. 1 to 99 is selectable. 750 RS485 CAMERA SWITCHER=SLAVE1(1 of 5) CAM LCN PORT CAM LCN PORT 1 21 9 51 2 22 10 52 3 23 11 53 4 24 12 54 5 25 13 55 6 26 14 56 7 27 15 57 8 28 16 58 LCN:LOGICAL CAMERA NUMBER 800 OPERATOR REGISTRATION OPERATOR NO.=1 ID =150 PRIORITY= 1 PASSWORD =∗∗∗∗∗ LEVEL = 1 SWITCHER=SLAVE(1 of 5) CAM LCN CAM LCN 1 21 VIEW&CONTROL 9 51 VIEW&CONTROL 2 22 VIEW ONLY 10 52 VIEW&CONTROL 3 23 VIEW&CONTROL 11 53 VIEW ONLY 4 24 VIEW ONLY 12 54 VIEW&CONTROL 5 25 VIEW&CONTROL 13 55 VIEW&CONTROL 6 26 VIEW&CONTROL 14 56 VIEW&CONTROL 7 27 VIEW&CONTROL 15 57 PROHIBITED 8 28 VIEW&CONTROL 16 58 PROHIBITED
77 ■MULTIPLEXER ●How to Display To display this menu on the monitor, move the cursor to 900 MULTIPLEXER in SETUP MENU by moving the joystick to Dor C. Then, press the CAM (SET) button. The submenu appears on the monitor. ●Parameters Move the joystick to move the cursor. Press the NEXT or PREV button to select the desired para- meters. SWITCHER:Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters. * In normal connection, only MASTER is displayed. Ver. ∗. ∗∗:Firmware version of a Multiplexer board • ALARM EXT.:Select this to gen-lock the unit with the recorder when an alarm is input to the unit. 002,004 to 128 (field):Select one of these alarm recording rates if the asynchronous unit is connect- ed to the unit. The factory default setting is EXT. MUX• CAM 01 to 16: These stand for an operators camera operation coverage. The following are the parameters. VIEW & CONTROL:The operator can display the cam- era image on the monitor and control panning/tilt- ing. VIEW ONLY:The operator can display the camera image on the monitor, but cannot control the pan- ning/tilting. PROHIBITED:The operator can neither display the camera image on the monitor nor control the pan- ning/tilting. The following is the factory default setting of this menu. Note:When you enter an invalid number, the parameter will return to the state before your numerical entry. 6 OPERATOR NO. ID PASSWORD LEVEL PRIORITY 1150 150 1 1 2112345 1 2 3100 100 1 3 4101 101 1 4 5102 102 2 5 6103103 3 CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to 6) 900 MULTIPLEXER SWITCHER=SLAVE1(1 of 5) Ver.∗.∗∗ VCR REC MODE 910 ALARM EXT. 920 NORMAL EXT. 930 DYNAMIC REC OFF 940 DUMMY BLACK ON 950 CAM SW LOSS ON 900 MULTIPLEXER SWITCHER=MASTER(5 of 5) Ver.∗.∗∗ VCR REC MODE 910 ALARM --- 920 NORMAL --- 930 DYNAMIC REC --- 940 DUMMY BLACK --- 950 CAM SW LOSS ---
78 • NORMAL EXT.:Select this to gen-lock the unit during the normal operation. 002,004 to 255 (field):Select one of these normal recording rates if the asynchronous unit is connect- ed to the unit. The factory default setting is EXT. • DYNAMIC REC PRI.:Select this to give recording priority to the camera channel with the alarm input. ONLY:Select this to record the images from the alarm- associated camera channel. GROUP:Select this to give recording priority to a group of up to 4 camera channels associated to the alarm input. OFF:Select this to deactivate the alarm priority mode. The factory default setting is OFF. • DUMMY BLACK ON:Select this to display the black picture for a camera channel that is not connected to the camera. OFF:Select this to skip the camera channels that are not connected to the camera in the sequence/spot mode. The factory default setting is ON. • CAM SW LOSS ON:Select this to make “CAMSW LOSS R∗” light up on the associated monitor when loss of the camera switching pulse is detected. OFF:Select this not to make “CAMSW LOSS R∗” appear on the associated monitor when loss of the camera switching pulse is detected. The factory default setting is ON. Note:If EXT. is selected for 910 ALARM/920 NORMAL, the playback images cannot be displayed on the monitors which are not connected to the EXT IN connector. Confirm the images on those which are connected to the recorder. ■MUX CAMERA TITLE ●How to Display To display this menu on the monitor, move the cursor to 1000 MUX CAMERA TITLE in SETUP MENU by moving the joystick to Dor C. Then, press the CAM (SET) button. The submenu appears on the monitor. ●How to edit The factory default settings are same as the illustration. The editing procedure is the same as 500 CAMERA TITLE. (Refer to p. 71.) Notes: •Up to 8 alphanumeric characters are available for each Multiplexer board camera title. •When moving the joystick to Dat the last text box of CAM 8 TITLE, the cursor will move to the first text box of CAM 9 TITLE. •When moving the joystick to Cat the first text box of CAM 9 TITLE, the cursor will move to the last text box of CAM 8 TITLE. •If five units are connected in the system, you can configure no parameters for MASTER. MUX 1000 MUX CAMERA TITLE SWITCHER=SLAVE1(1 of 3) CAM LCN TITLE CAM LCN TITLE 1 1 C01 9 09 C09 2 2 C02 10 10 C10 3 3 C03 11 11 C11 4 4 C04 12 12 C12 5 5 C05 13 13 C13 6 6 C06 14 14 C14 7 7 C07 15 15 C15 8 8 C08 16 16 C16 LCN:LOGICAL CAMERA NUMBER
79 Trademarks •IBM is a trademark of International Business Machines Corporation. •Intel and Pentium are trademarks of Intel Corporation. •Microsoft ® Windows®are either registered trademarks of Microsoft Corporation in the United States and/or other countries. •VD2 is the original synchronization system of Matsushita Electric Industrial Co., Ltd. •Other company names and product names appearing in the manual are registered trademarks or trademarks of the company concerned. Platform To install WJ-SX150A Administrator Console, the PC should meet the following requirements. •Hardware requirements IBM PC or 100 % compatible, Pentium 3- equivalent or higher, 128 MB RAM, 5 MB hard drive space with additional space for configuration database (.sdt) and log. In addition, the PC must be equipped with a serial port. •Operating system requirements Microsoft ®Windows®98, 98 SE, 2000, XP Professional •Video display setting requirements *High color (16 bit) or higher *800 x 600 resolution When installing in the default system setting, the software is installed in the following directory: C: \Program Files\Panasonic\SX150A ■Installation/Uninstallation ●Installation Insert the CD-ROM program disk into the CD-ROM drive on the PC. The file is located in the following directory. E: \Admin\Setup.exe Double-click Setup.exe to begin the installation. Respond to the dialog boxes by following the directions given. ●Uninstallation 1. Select Start – Settings – Control Panel. 2. Click on the Add/Remove Hardware button. 3. Select WJ-SX150A Administrator Console and click on Add/Remove. 4. Operate according to the direction in the window. ■Description of WJ-SX150A Administrator Console WJ-SX150A Administrator Console is a utility software which can configure the system settings and control data of this surveillance system. WJ-SX150A Administrator Console can configure the follow- ing settings. ●MASTER-SLAVE •Master-Slave (p. 81) •Logical Camera Number (p. 82) ●MANAGEMENT •Put a file to SX150A (p. 83) •Get a Configuration Data from SX150A (p. 83) ●SETUP Sequence Settings •Tour Sequence (p. 84) •Group Sequence (p. 85) Schedule Settings •Timer Event (p. 85) •Camera Cleaning (p. 86) •Daylight Saving Time/Summer Time (p. 87) Alarm Settings •Alarm Mode (p. 88) •Alarm Event (p. 89) •Alarm Port (p. 90) Operator Settings •Operator Registration (p. 90) •Level Table (p. 91) •Monitor Selection (p. 92) •Auto Login/Logout (Auto Log-in/Log-out) (p. 92) System Settings •Time & Date (p. 93) •Cable Compensation/VD2/DATA (p. 94) •Camera Title (p. 94) •Data Port (p. 96) •Recorder (p. 97) •Multiplexer Mode (p. 98) •Multiplexer Title (p. 100) WJ-SX150A Administrator Console •New (p. 101) •Select Setup Data File (p. 101) •Account Manager (p. 101) •Communication Port (p. 102) MUX MUX WJ-SX150A ADMINISTRATOR CONSOLE
80 3. When terminating the software, click on the EXIT button or press the ESC button on the PC keyboard. The main window will close and WJ-SX150A Administrator Console will be terminated. Note: The operator name and password are changeable. Operator addition is also available. The configuration of each operator name, password and level are neces- sary. (Refer to p. 101 Account Manager.) ■The Main Window This window appears when starting up WJ-SX150A Administrator Console. Clicking on each button in the window will display the asso- ciated configuration window. Refer to the description of each window for details. ●Before Using WJ-SX150A Administrator Console 1. Select Start – Program – Panasonic – WJ-SX150A Administrator Console x.xx* or double-click the WJ- SX150A Administrator Console x.x icon on the desktop. *x.xx is a version number. 2. When you launch WJ-SX150A Administrator Console for the first time, the following window will appear on the PC screen. Select “Yes”. →The selection will be memorized to WJ-SX150A Administrator Console while launching it. Note:To change the selection you have done in the Startup Menu window, restart the WJ-SX150A Administrator Console while holding down the SHIFT key on the PC keyboard. ●Startup/Termination 1. Select Start – Program – Panasonic – WJ-SX150A Administrator Console x.xx* or double-click the WJ- SX150A Administrator Console x.x icon on the desktop. *x.x: Software version →The User ID and Password Required window will appear on the PC screen. 2. Enter admin and sx150 in the boxes Name and Password respectively. Then, click on the OK button. →WJ-SX150A Administrator Console starts up and the main window will appear on the PC screen. EXIT button Minimizing button
81 (Multiplexer Mode): Multiplexer Mode window (p. 98) (Multiplexer Title): Multiplexer Title window (p. 100) In addition, the main window has the following buttons. (New): New window (p. 101) (File Open): Select Setup Data File window (p. 101) (Account Manager): Account Manager window (p. 101) (Communication Port): Communication Port window (p. 102) (Panasonic): Opens the version information window of WJ- SX150A Administrator Console. Clicking on OK button will close the window. Note:To reflect each configuration to the system, save the file by pressing the SAVE button before closing the win- dow. After that, be sure to put the file from the PC to the unit. ■Master-Slave This window configures the composition of master-slave connection. Recorders selected in the Recorder window (p. 97) are activated/deactivated in the Master-Slave window. ●How to Display To display this window, click on the (Master-Slave) button in the main window (p. 80). ●How to Display • Master The Master unit and the connected recorder are displayed. MUX MUXMASTER-SLAVE (Master-Slave): Master-Slave window (p. 81) (Logical Camera Number) Logical Camera Number window (p. 82) MANAGEMENT (Put to SX150A): Put a file to SX150A window (p. 83) (Get from SX150A): Get a Configuration Data from SX150A window (p. 83) SEQUENCE (Tour Sequence): Tour Sequence window (p. 84) (Group Sequence):Group Sequence window (p. 85) SCHEDULE (Timer Event): Timer Event window (p. 85) (Camera Cleaning): Camera Cleaning window (p. 86) (Daylight Saving Time/Summer Time): Daylight Saving Time/Summer Time window (p. 87) ALARM (Alarm Mode): Alarm Mode window (p. 88) (Alarm Event): Alarm Event window (p. 89) (Alarm Port): Alarm Port window (p. 90) OPERATOR (Operator Registration): Operator Registration window (p. 90) (Level Table): Level Table window (p. 91) (Monitor Selection): Monitor Selection window (p. 92) (Auto Login/Logout): Auto Login/Logout window (p. 92) SYSTEM (Time & Date): Time & Date window (p. 93) (Cable Compensation/VD2/DATA): Cable Compensation/VD2/DATA window (p. 94) (Camera Title): Camera Title window (p. 94) (Data Port): Data Port window (p. 96) (Recorder Control): Recorder window (p. 97)
82 • Slave Slave units and connected recorders are displayed. To activate/deactivate Slave units, click the ON/OFF button of a desired Slave unit. When Slave units are set to ON, their unit names become selectable in SETUP MENU to config- ure the parameters. (Save Exit) button Saves the configuration and closes the Master-Slave win- dow. (Cancel Exit) button Cancels the configuration and closes the Master-Slave win- dow. Notes: •If you configure the master-slave composition, settings concerning LCN (logical camera number) and Multiplexer Title (refer to p. 100) will be changed. When you click on the Save Exit button, a message window will appear to confirm you the change. •In WJ-SX150A Administrator Console, camera channels of the Master unit which are connected to MONITOR OUT 1/2/3/4 of Slave units are displayed in gray. You cannot configure the parameters. ■Logical Camera Number This window configures logical camera numbers assigned to camera channels of each unit. During operation, logical camera numbers are used for camera control and monitor display. To display this window, click on the (Logical Camera Number) button in the main window (p. 80). ●How to Display • CAM 1 to 16 This stands for a camera channel of the unit. • Logical Camera Number Click on each drop-down menu to select a desired logical camera number. 1 to 99 is selectable. For camera channels without camera connections, select “- -“. (Save Exit) button Saves the configuration and closes the Logical Camera Number window. (Cancel Exit) button Cancels the configuration and closes the Logical Camera Number window. Notes: •If logical camera numbers are not selected, the cam- eras’ LCNs are not displayed in each window of SETUP MENU and WJ-SX150A Administrator Console. •You can select a logical camera number for only one channel. When you select the same number more than one time, a message will appear. The message will noti- fy you that the number has been already used. If you click on “Yes”, the newer will be activated and the older will be changed to “- -“. If you click on “No”, the changed parameters will return to the former state. •If five units (Master and Slave 1 to 5) are connected in the system, you cannot select logical camera numbers for Master.
83 ■Put a file to SX150A Pressing this button will start the putting of the configuration file from the PC to the unit. ●How to Display To display this window, click on the (Put to SX150A) button in the main window (p. 80). ●Parameters The file name of the configuration data appears. (OK) button To put the configuration file from the PC to the unit, click on this button. (Cancel Exit) button To cancel the putting of the configuration file from the PC to the unit, click on this button. Notes: •The setup file has been configured at the factory, and the file names appear on the main windows title bar. •Put the file from the PC to the unit when the time with no necessary to the continuous system operation, such as after-hours. After the file putting, the system will auto- matically restart. Then, the system controllers will tem- porarily log out. •To change a file, select a file again. (Refer to p. 101 Select Setup Data File.) •The configuration file cannot be put to the unit while opening SETUP MENU. •It takes a few seconds to put a file to SX150A, and you might assume the PC has been freezing. Wait until the message “Completed!” appears on the screen. If the message “Connection error” appears, the PC is incorrectly connected to the unit. Confirm the set- tings of WJ-SX150A Administrator Console and retry the file putting. (Refer to p. 74 CAMERA/DATA 1-4 PORT and p. 102 Communication Port.) ■Get a Configuration Data from SX150A Pressing this button will start the getting of the configuration data from the unit to the PC. ●How to Display To display this window, click on the (Get from SX150A) button in the main window (p. 80). ●Parameters The file name of the configuration data appears. (OK) button To get the configuration data from the unit to the PC, click on this button. (Cancel Exit) button To cancel the getting of the configuration data from the unit to the PC, click on this button. Notes: •The configuration data getting is also possible during the surveillance, for it will not interfere with the system operation. •The past data will be overwritten when getting a new configuration data. •To change the getting directory, select it. (Refer to p. 101 Select Setup Data File.) •When the file getting has been successfully executed, “Completed!” will appear. If “Connection Error” appears, confirm the connection and the serial port set- ting of the PC and the unit. (Refer to p. 74 CAMERA/DATA 1-4 PORT and p. 102 Communication Port.) If “Failed!” appear, retry the file getting.