Panasonic Kx Tva50 Installation Manual
Here you can view all the pages of manual Panasonic Kx Tva50 Installation Manual. The Panasonic manuals for System are available online for free. You can easily download all the documents as PDF.
Page 141
Example Settings (3) Program the PBX to direct incoming trunk (CO line) calls to an Incoming Call Distribution (ICD) group, and to then direct those calls to the VPS when they are not answered. 1. Program the PBX so that incoming trunk (CO line) calls are directed to an ICD group (DIL feature). a. Go to the CO & Incoming Call-DIL Table & Port Setting screen. b. Assign the DIL Destination for each time mode and trunk (CO line) to a specific extension number (floating extension number of the ICD...
Page 142
d.Click Apply to save the changed data. 3.Program the PBX so that it will direct overflowed calls to the VPS. a. Go to the Groups-VM(DTMF) Group-System Setting screen. b. Select None, Answer by Mailbox , or AA as the parameter for Intercept Routing to the VPS Sequence . This parameter determines which DTMF command the PBX will send to the VPS in order to select the desired service (AA, VM, Custom Service, etc.). If using a Custom Service, select None. 142Installation ManualDocument Version 3.0...
Page 143
c.Click Apply to save the changed data.Document Version 3.0 2010/06Installation Manual1435.3 KX-TDE, KX-TDA, and KX-TAW Series PBX Programming for Inband Integration
Page 144
5.4 KX-TA824 PBX Programming for Inband Integration The instructions in this section are for programming a KX-TA824 via the Operating and Maintenance Tool. To program a KX-TA824 using the Manager Extension, follow the instructions for KX-TA series PBX programming by referring to 5.7 KX-TA Series PBX Programming for Inband Integration. 1. Go to the 1.System - 2.Main screen. 2. Under Voice Mail , select DTMF Integration , then select each extension jack that is connected to the VPS. Click Apply to...
Page 145
5.Set the Extension Hunting type for the VPS extension groups to Circular. Click Apply to save the changed data. 6. Go to the 2.Extension - 2.Feature Settings screen. Document Version 3.0 2010/06Installation Manual1455.4 KX-TA824 PBX Programming for Inband Integration
Page 146
7.Enable Data Line Security for each extension connected to the VPS. Click Apply to save the changed data. 8. Program the appropriate trunk (CO line) feature settings depending on how your customer plans to use the VPS: a) to answer all incoming calls, b) as an operator backup, or c) to only answer calls not answered by user extensions. a. If the VPS is answering all calls: Go to the 3.CO - 1.Line Mode screen. Program all lines DIL to the first extension of the Voice Mail hunt group. The PBX will...
Page 147
Go to the 3.CO - 2.Incoming / Outgoing screen. Program lines to ring operator extensions immediately for all time modes. To give the operator (extension 101 in this example) time to answer the call before the VPS picks up, we recommend setting the delay to a few seconds for each extension connected to the VPS. Set a different delay time for each extension connected to the VPS. Finally, go to the 3.CO - 1.Line Mode screen and set all trunk (CO line) types to Normal. Click Apply to save the changed...
Page 148
for each extension connected to the VPS. Finally, go to the 3.CO - 1.Line Mode screen and set all trunk (CO line) types to Normal. Click Apply to save the changed data.148Installation ManualDocument Version 3.0 2010/065.4 KX-TA824 PBX Programming for Inband Integration
Page 149
5.5 KX-TD Series PBX Programming for Inband Integration For KX-TD500 programming, refer to 5.6 KX-TD500 PBX Programming for Inband Integration. DPT Integration is recommended when using the VPS with the KX-TA1232, KX-TD816, or KX-TD1232, however, Inband Integration is necessary when the software version of the PBX does not support DPT Integration. Programming procedures and availability may vary by PBX model, software version, etc. Refer to the documentation included with the PBX or consult your dealer...
Page 150
5.6 KX-TD500 PBX Programming for Inband Integration DPT Integration is recommended when using the VPS with the KX-TD500, however, Inband Integration is necessary when: • the PBX has available SLT ports but no available DPT ports. • the cards installed in the PBX or the software version of the PBX do not support DPT Integration. Programming procedures and availability may vary by PBX model, software version, etc. Refer to the documentation included with the PBX or consult your dealer for more...