Page 511

Alarm codes / 511
P0992638 03Modular ICS 6. 0 Installer Guide
2. If there are no devices connected to the Station Module, 
connect one and then press CLEAR
.
3. If there are any devices connected to the Station Module, 
check all the wiring associated with the devices.
4. Refer to Data Module down on page 575.
Alarm: 51-X 
1. Check the wiring from the ICS to the TM.
2. Refer to Problems with trunk cartridges service on page 
566.
Alarm: 52-X-Y
1. Follow the procedure in Problems with trunk cartridges...

Page 512

512 / Alarm codes
Modular ICS 6.0 Installer GuideP0992638 03
OR
Install a Trunk Cartridge in slot Y that matches the type of 
trunk you have configured.
Alarm: 62-X-Y
1. Check that the proper Trunk Cartridges are inserted in the 
proper slots of the Trunk Module.
2. Enter programming and look under the Trk/Line data 
heading. 
Check that the Trunk mode and Answer mode settings do 
not conflict for every line connected to Trunk Cartridge Y. 
If Trunk mode is set to unsupervised, Answer mode must 
be set...

Page 513

Alarm codes / 513
P0992638 03Modular ICS 6. 0 Installer Guide
Alarm 68-Z
1. Locate the device(s) connected to port(s) not available for 
that device type.
2. Power down the system. 
3. Disconnect the device from the port identified. 
4. Reconnect it to a valid port.
Alarm 75
1. Check the connection to your ISDN service provider.
Alarm: 76-X 
1. Check the wiring from the ICS to the DM.
2. Refer to Problems with trunk cartridges service on page 
566.
3. Refer to Data Module down on page 575. 

Page 514

514 / Event messages
Modular ICS 6.0 Installer GuideP0992638 03
Event messages
Event messages appear as items in the System administration 
log or the System test log of the Maintenance session. Most of 
these event messages can only be caused by an unusual 
combination of events, and should rarely occur. 
Each event is assigned a severity number. An S preceding this 
number, S4 for example, may appear in the event message. 
S9 is the most severe. If the log is full, new event messages 
with a higher...

Page 515

Event messages / 515
P0992638 03Modular ICS 6. 0 Installer Guide
Significant event messages 
The following table lists event messages that are relevant to 
Maintenance activities. The time that the message is recorded 
is also provided.
Displays
Event messageThe event message is recorded when…
Evt:210-YYYZ S4Loopback test YYY on Trunk Cartridge Z has 
started
Evt:211-YYYZ S4Loopback test YYY on Trunk Cartridge Z has 
stopped
Evt:220-3546  S4the Sys admin log has been cleared by the DN 
(3546 in this...

Page 516

516 / Event messages
Modular ICS 6.0 Installer GuideP0992638 03
Evt:269-3546 S8the Line/set filter for the DN (3546 in this case) has 
lost data due to a fault in the system memory
Evt:299 S1the system powers up after a power failure
Evt:327 S5short term alarm threshold has been surpassed in 
the DTI cartridge
Evt:328  S5short term alarm threshold has been surpassed in 
the DTI cartridge
Evt:329  S5short term alarm threshold has been surpassed in 
the DTI cartridge
Evt:330  S5short term alarm threshold...

Page 517

Event messages / 517
P0992638 03Modular ICS 6. 0 Installer Guide
Evt:422-3546 S6a length change by the DN (3546 in this case) has 
been requested
Evt:423-3546 S6an individual DN change has been requested by the 
DN (3546 in this case)
Evt:441  S2a timeout occurred while waiting for ANI or DNIS 
digits to be received
Evt:442  S5a timeout occurred while waiting for ANI or DNIS 
digits to be received
Evt:453  S4Someone entering **CONFIG
Evt:454  S5Invalid password entered
Evt:458   S4Call-by-Call NVRAM data...

Page 518

518 / Event messages
Modular ICS 6.0 Installer GuideP0992638 03
Event message 799
Event message 799 indicates a call processing error has 
occurred on an ISDN line. The event number is followed by a 
number representing the line or loop number, and a code for 
the type of error. 
Evt:698  S8incorrect software key entered
EVT799-00040B
   S7a call processing error on the fourth BRI loop; see 
Event message 799 on page 518.
Evt:822  S8Alarm code 63 is sent because there are no DTMF 
receivers for an...

Page 519

Event messages / 519
P0992638 03Modular ICS 6. 0 Installer Guide
Displays
You should rarely see any event messages that are not 
described in the Significant event messages on page 515. If 
you do see one of these event messages, the Norstar system has 
followed its normal recovery from an unusual combination of 
system events. Although the problem is not a serious one, 
repeated occurrences of the event number should be reported 
as soon as possible.
As a result of some events, the Norstar system...

Page 520

520 / Event messages
Modular ICS 6.0 Installer GuideP0992638 03
Most of these events are recorded in the Sys test log. The few 
exceptions to this are recorded in the Sys admin log, as 
indicated.
Event
MessageSystem 
RestartEvent 
MessageSystem 
Restart
101-106Ye s400 (Admin log)Ye s
107No401-403No
108-112Ye s405-411No
113No412-419 (Admin log)No
114-116Ye s421-423 (Admin log)No
117No424-425No
118-120Ye s426-430Ye s
121-123No431No
124-125Ye s432Ye s
126-129No433No
130Ye s441-442No
131-132No453No...
Start reading Nortel Modular Ics 6.0 Installer Guide

Related Manuals for Nortel Modular Ics 6.0 Installer Guide

All Nortel manuals