Hardware / 471 P0992638 03Modular ICS 6. 0 Installer Guide BRI card LoopInstaller password required The display shows the loops found on the BRI card. Press ‘ to display the settings for individual loops on a BRI card. Type Press CHANGE to select the loop type. If the card type is BRI-ST, the loop type can be S, or T. If the card type is BRI-U2 or BRI-U4, the loop type can be LT or NT. Lines There are two lines for each T or NT loop. The BRI card must be disabled in Module status before this...
Page 472
472 / Hardware Modular ICS 6.0 Installer GuideP0992638 03 No SPIDs assigndInstaller password required T and NT loops can be assigned a system profile identifier (SPID) as supplied by your service provider. No SPIDs are assigned by default. When the loop type is T, calls on the loop are handled for a network connection only. If any other ISDN equipment is connected to the loop, it must be configured as an S loop to ensure proper call handling. 1. Press ADD and enter the first or second SPID assigned...
Page 473
Hardware / 473 P0992638 03Modular ICS 6. 0 Installer Guide Network DNsInstaller password required 1. Press ≠ to display the DNs which are used with the SPID. 2. Press ADD and enter the appropriate number to assign additional Network DNs to the SPID. The Modular ICS can have a maximum of 128 Network DNs for the system. There is no limit to the number of Network DNs for each SPID, but you cannot exceed the limit of 128 Network DNs for the system. If the Network DN you try to enter is already assigned...
Page 474
474 / Hardware Modular ICS 6.0 Installer GuideP0992638 03 D-packet servceInstaller password required 1. Press ≠ to view and program D-packet service for T or NT loops. You can have two D-packet service configurations for each BRI card. 2. Press CHANGE to turn D-packet service for this loop on (Y) or off (N). Lp Installer password required 1. Select the S loop (for BRI-S/T cards) or LT loop for BRI- U2 or BRI-U4 cards that supports the D-packet service. 2. Press CHANGE to move through a list of the...
Page 475
Hardware / 475 P0992638 03Modular ICS 6. 0 Installer Guide No TEIs on loopInstaller password required Press ADD to program up to eight TEIs to this loop. Sampling Installer password required Press CHANGE to select the sampling used by an S loop: Fixed — if two or more S-interface devices use the loop and the length of the loop is less than 200 m (650 ft.), select Fixed. Adaptve — if two or more S-interface devices use the loop and the length of the loop is greater than 200 m (650 ft.), select...
Page 476
476 / Hardware Modular ICS 6.0 Installer GuideP0992638 03 Assign DNsInstaller password required 1. Press ≠ and enter the ISDN DN you wish to assign to this loop, or press SCAN to move through a list of DNs already assigned to the loop. The display shows: Availabl, Assigned — assigned to this loop *Lpnnn* — assigned as the default DN of another loop Lpnnn — assigned to another loop 2. Press LIST to view the DNs assigned as ISDN DNs. The default ISDN DN range is 667-696. For information about...
Page 477
Hardware / 477 P0992638 03Modular ICS 6. 0 Installer Guide Norstar systems are stratum 4E equipment and are usually used as termination points in a network. For each DTI, choose one of the following settings: Primary reference The DTI obtains the timing reference from the network, which the system synchronizes to. This is the default value for the DTI in slot 1 in the ICS. If the system is configured with a DTI card that has been configured as PRI, the setting should be set to Primary. Secondary...
Page 478
478 / Hardware Modular ICS 6.0 Installer GuideP0992638 03 The following illustrations show some typical network configuration and the appropriate clock source settings for your DTIs. Norstar connected directly to the service provider in a T1 network The installer should ensure that clock source loops are either not powered down or are among the last to be powered down. If BRI cards are used only for S-loops, a Service Card is required only if the DTI is T1. However, a Services Card is recommended...
Page 479
Hardware / 479 P0992638 03Modular ICS 6. 0 Installer Guide Norstar connected to another switch or MUX in a T1 or PRI network Norstar connected to another switch in a closed T1 or PRI network Norstar ICS Primary - DTI 1 obtains the timing from the network Secondary - DTI 2 acts as a standby to obtain the timing from the network T1 service provider Other switch or MUX in networkNorstar ICS T1 or PRI ser vice provider Primary - DTI 1 obtains the timing from the network Secondary - DT12 acts as a standby to...
Page 480
480 / Hardware Modular ICS 6.0 Installer GuideP0992638 03 Norstar connected in a series of switches in a T1 or PRI network Norstar connected by a T1 link to another switch in an analog network Norstar ICS Primary - DTI 1 obtains the timing from the T1 service provider Timing master - DTI 1 transmits the systems timing to the other switch T1 service provider Norstar or other switch Primary reference T1 or PRI service provider Primary referencePrimary - DTI 1 obtains timing from T1 service provider...