Home > Nortel > Communications System > Nortel Modular Ics 6.0 Installer Guide

Nortel Modular Ics 6.0 Installer Guide

Here you can view all the pages of manual Nortel Modular Ics 6.0 Installer Guide. The Nortel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 501

System test log / 501
P0992638 03Modular ICS 6. 0 Installer Guide
Erasing the logInstaller password required
Start with the display showing Items in log:.
1. Press ERASE
. Erase log?displays.
2. Press YES
.
If no new items have been added since the list was entered, 
the log is erased and the display shows Lo gerased.
If new items have been added since the list was entered, the 
display briefly reads Cancld-new items and returns to 
the display Items in log:.
3. Press – to return to Sys test log. 

Page 502

502 / System administration log
Modular ICS 6.0 Installer GuideP0992638 03
System administration log
The System administration log keeps a record of 
administrative events such as sessions in which a change was 
made, invalid password attempts, and password changes. 
You can use this feature to:
check the items in the log
erase the log
check when each item in the log occurred
The System administration log holds a maximum of 10 items. 
Erase the log after dealing with all the items.
Checking the items...

Page 503

System administration log / 503
P0992638 03Modular ICS 6. 0 Installer Guide
Checking the current alarm 
Start with the display showing Items in log:.
1. Press ALARM
. The display shows an alarm code. 
If there is no current alarm, ALARM
 does not appear on the 
display.
2. Press OK
 to return to the display showing Items in log:.
Checking when each item in the log occurred
Start with any display showing a log item:
1. Press TIME
. The display shows the date and time.
2. Write the date and time on the...

Page 504

504 / Network evt log
Modular ICS 6.0 Installer GuideP0992638 03
Network evt log
The Network evt log keeps a record of events and alarms that 
are specific to the T1 network interface. 
You can:
check the items in the log
erase the log
check when each item in the log occurred
The Network evt log holds a maximum of 20 items. Erase the 
log after dealing with all the items.
Checking the items in the log
Start with Sys admin log on the display:
1. Press  ‘. Network evt log displays.
2. Press ≠. Items in...

Page 505

Network evt log / 505
P0992638 03Modular ICS 6. 0 Installer Guide
Erasing the log
Start with Items in log: on the display.
1. Press ERASE
. 
The display shows Erase log?.
2. Press YES
. 
If no new items have been added since the list was entered, 
the display shows Log erased.
If new items have been added since the list was entered, the 
display briefly reads Cancld-new items and returns to 
the display Items in log:.
3. Press – to return to Network evt log.
Checking when each item in the log occurred...

Page 506

506 / Alarm codes
Modular ICS 6.0 Installer GuideP0992638 03
Alarm codes
The Norstar ICS system generates alarm codes after system 
disconnections or after certain anomalies in system operation. 
All alarm codes appear at the Alarm telephone and in the 
System test log of a Maintenance session. 
For a more complete description of alarm and event codes 
consult your technical support representative. The following 
figure shows an alarm code appearing on a Norstar Alarm 
telephone display.
Tips - The Alarm...

Page 507

Alarm codes / 507
P0992638 03Modular ICS 6. 0 Installer Guide
If you see an alarm code
1. Write the alarm code on the Sys test log record.
2. Determine the cause of the alarm from the following table.
3. Follow Alarm troubleshooting on page 510.
4. Press TIME
 to see when the alarm occurred.
5. Press CLEAR
 to clear the alarm.
An alarm code may not be displayed until two minutes after it 
has been triggered. If the ICS is powered off when the alarm is 
triggered, the alarm code is not displayed until two...

Page 508

508 / Alarm codes
Modular ICS 6.0 Installer GuideP0992638 03
Alarm: 
37 ABBC
DD An error has occurred in 
the download of a protocol 
to a BRI Card. 
A: the maintenance index 
of the BRI
BB: a code describing the 
nature of the error 
C: the current download 
state 
DD (appears when the 
error is limited to one 
protocol): the two-
character product identifier 
of the protocolThe BRI Card is not properly 
installed. 
Alarm: 40
Alarm: 41
Alarm: 42
Alarm: 43
Alarm: 44
Alarm: 45
Alarm: 46
Alarm: 47There is...

Page 509

Alarm codes / 509
P0992638 03Modular ICS 6. 0 Installer Guide
X = DS-30 port numbers, Y = Trunk Cartridge number (numbered from left to 
right), and Z = Trunk port number
Alarm: 
52 X YTC disconnected from TM Trunk Cartridge Y on DS-30 
port X is disconnected from 
the TM.
Alarm: 
61 X YIncompatible Trunk 
CartridgeTrunk Cartridge Y on DS-30 
port X cannot operate with the 
Trunk type assigned to it in 
Configuration.
Alarm: 
62 X YUnsupported Auto-answer 
setting (Loop Start TCs)Trunk Cartridge X on...

Page 510

510 / Alarm codes
Modular ICS 6.0 Installer GuideP0992638 03
Alarm troubleshooting
Refer to the previous table before following these procedures.
Alarm: 10
1. Check to see if there is a device connected to the ICS (that 
has a port number beginning with the number 1).
2. If there are no devices connected to the ICS, connect one 
and then press CLEAR
.
3. If there are any devices connected to the ICS, check all the 
wiring associated with the devices.
4. Refer to Problems with BRI service on page 570....
Start reading Nortel Modular Ics 6.0 Installer Guide

Related Manuals for Nortel Modular Ics 6.0 Installer Guide