Telco features / 451
P0992638 03Modular ICS 6. 0 Installer Guide
Program ONN blocking BRI loop state
The display shows the loops found on the BRI card.
1. Press ‘ to display the settings for individual 
loops on a BRI card.
2. At the Loops display, press next to display the first loop 
number.
3. Press ≠. Type:T displays.
4. Press ‘ until ONNblk:SuprsBit displays.
5. Press CHANGE
 to toggle the BRI loop state setting from 
SuperBit to SrvcCode.
6. Repeat steps 1 to 4 to program ONN blocking BRI loop...

Page 452

452 / Software keys
Modular ICS 6.0 Installer GuideP0992638 03
Software keys
Some of the MICS system features require special pass codes, 
called software keys, to make the feature work. This section 
describes each of these options. To obtain the required 
Software key, call the Integrated Voice Response (IVR) 
Center at: 1-800-4NORTEL (667835), then use Express 
Routing Code 1599.
ISDN-PRI
A software key is required so that you can configure a DTI 
card as a PRI card.
MCDN
To create a private network...

Page 453

Software keys / 453
P0992638 03Modular ICS 6. 0 Installer Guide
System Identification Number
Obtain the System ID (SysID) by pressing 
²¥¥êçêéë, or ²¥¥àáàÝÜ 
on any system set.
This information is also available by accessing 
Software keys in an Installer programming session:
1. Press ≠ The display reads SysID: followed by 
the unique System Identification Number.
2. Press ‘ to continue in Software keys or 
¨ to exit.
3. Record the SysID in the Modular ICS Programming 
Record.
Call the Nortel Customer...

Page 454

454 / Software keys
Modular ICS 6.0 Installer GuideP0992638 03
Entering the software keys
Keys are entered by accessing Software keys in a 
programming session.
1. Press ≠. The display reads SysID:.
2. Press ‘. The display reads Password keys.
3. Press ≠. The display reads Key 1:_.
4. Enter the eight-digit password number for Key 1. 
Use BKSP
 to make corrections. The display reads Key 2:_. 
5. Enter the eight-digit password number for Key 2. 
6. Proceed as above until you have finished entering Key 3....

Page 455

Hardware / 455
P0992638 03Modular ICS 6. 0 Installer Guide
Hardware
Hardware is where you view and change settings for cartridges 
installed in the ICS, Trunk Modules, Station Modules, and 
Data Modules.
Show module
Installer password required
The Show module setting automatically displays the modules 
connected to the system. Press ‘ to select the setting: 
KSU, Mod 03, Mod 04, Mod 05, Mod 06, Mod 07, Mod 08.
Note: MICS-XC has 14 modules.
Cards on KSU
Installer password required
The Cards on KSU setting...

Page 456

456 / Hardware
Modular ICS 6.0 Installer GuideP0992638 03
Once you specify the type of Trunk Cartridge in the ICS slot, 
press ≠ to display the range of line numbers for the 
lines on the Trunk Cartridge.
Provisioning the DTI card for PRI
The Cards on KSU setting allows you to specify the type of 
Trunk Cards in the ICS. 
Note:  Remember, you require a software password to activate 
PRI on your system. 
Start with the display showing Hardware.
1. Press ≠. The display shows Show module.
2. Press ‘. The...

Page 457

Hardware / 457
P0992638 03Modular ICS 6. 0 Installer Guide
3. Press CHANGE to select a different protocol from the table 
that follows:
If you selected the NI-2 protocol, and you are using call-
by-call services, you must specify how Norstar should 
handle the NSF (Network Specific Facilities) information 
element as follows:
Press ≠. 
Press ‘ until the display shows the default 
protocol NSF EXT: None.
Press CHANGE
 to select another setting based on your 
switch type, as shown in the following...

Page 458

458 / Hardware
Modular ICS 6.0 Installer GuideP0992638 03
BchanSeq
B-channel sequence allows you to select either ascending or 
descending. You need to choose the opposite setting of your 
service provider. 
However, if all lines for two DTI cards (configured as PRI) are 
in the same PRI pool, then both cards must be set to use the 
descending B-channel sequence mode. As a result, the service 
provider must use ascending mode
Press CHANGE
 to select either ascending or descending.
Call-by-call routing
By...

Page 459

Hardware / 459
P0992638 03Modular ICS 6. 0 Installer Guide
3. Press CHANGE to change the mapping that is applied to 
incoming calls of this service type to obtain the received 
digits. In all cases, the received digits are used to find a 
target line or to activate Remote Access.
None — No mapping is applied. The received number 
length determines the number of digits of the Called Party 
Number which will be used as received digits. 
Note:  If there is no called party number, which may occur 
with some...

Page 460

460 / Hardware
Modular ICS 6.0 Installer GuideP0992638 03
Discon timer
Disconnect timer allows you to specify the duration of an 
Open Switch Interval (OSI) before a call on a supervised 
external line is considered disconnected. 
Press CHANGE
 to select the setting: 60, 100, 260, 460, or 600 
milliseconds. 
Answer timer
Installer password required
Answer timer allows you to set the minimum duration of an 
answer signal before a call is considered to be answered. 
Press CHANGE
 to select the setting: 1,...