Page 561
Problems with lines / 561 P0992638 03Modular ICS 6. 0 Installer Guide Possible problem The line has been disabled for maintenance purposes. Solution Enable the line. OR If the line will be out of service for some time, configure another line to replace it on the telephone. Possible problem The loop or line has not been provisioned. Solution Provision the loop or line. Selected line pool displays: No free lines If the user selects a line pool and the telephone displays No free lines, refer to this...
Page 562
562 / Problems with optional equipment Modular ICS 6.0 Installer GuideP0992638 03 Problems with optional equipment Analog Terminal Adapter 1. Check the connections to the jack. 2. Check the connections to the ATA. 3. Disconnect the ATA and replace it with a working telephone. If the telephone still works properly, the ICS and/or the SM are operating properly. 4. Verify that the programming has been done as described in the Programming Record and the Norstar Analog Terminal Adapter Installation Card...
Page 563
Problems with optional equipment / 563 P0992638 03Modular ICS 6. 0 Installer Guide Auxiliary ringer 1. If the auxiliary ringer is used for Schedules (Night, Evening, or Lunch service), ensure that Schedules is activated from the control telephone. 2. Check the wiring between the auxiliary ringer generator and the ringing device. Refer to the auxiliary ringer wiring chart. 3. Check the wiring between the auxiliary ringer generator and the distribution block: Auxiliary ringer wiring 4. Ensure that the...
Page 564
564 / Problems with optional equipment Modular ICS 6.0 Installer GuideP0992638 03 External paging 1. Use the Button Inquiry feature (²¥â) to verify the feature of a programmable memory button. 2. Check the wiring between the 50-pin connector and the paging amplifier or between the connections shown in the external paging wiring chart. External paging wiring 3. Test external paging ²ßÛ to ensure that it is working. The nominal output signal from the Norstar ICS is 100 mV across 600 Ω. Music on...
Page 565
Problems with optional equipment / 565 P0992638 03Modular ICS 6. 0 Installer Guide 5. Ensure that the music source is turned on, is operational, and the volume control is set properly. 6. Any music source with a low-output impedance, less than 3,300 Ω, can be connected. The output level must be less than one volt.
Page 566
566 / Problems with trunk cartridges service Modular ICS 6.0 Installer GuideP0992638 03 Problems with trunk cartridges service Check first for user problems, then wiring and programming errors before replacing Norstar equipment. 1. Check that the cartridge is properly inserted in the ICS or Trunk Module. 2. Run a Maintenance session to ensure that the cartridge is not disabled. If the problem persists: If the Trunk Cartridge is installed in the ICS and the AC power is present and the LED indicator...
Page 567
Problems with trunk cartridges service / 567 P0992638 03Modular ICS 6. 0 Installer Guide Refer to Installation on page 209 for information about replacing components. Digital Trunk Interface trouble 1. Run a Maintenance session to verify that the Trunk Cartridge is enabled and that the lines are provisioned. 2. Check the LEDs on the front of the DTI: Alarm: steady yellow LED upon LOS Error: steady yellow LED during Alarm: steady red LED during transmit Error: steady yellow LED upon Steady green...
Page 568
568 / Problems with trunk cartridges service Modular ICS 6.0 Installer GuideP0992638 03 Receive Alarm — yellow LED on indicates a problem with the digital transmission being received. This half- duplex link is unusable. Receive Error — yellow LED indicates a minor error as a result of degraded digital transmission. Possible causes are an ohmic connection, water ingress, or too long a loop. Transmit Alarm — red LED on indicates an inability to transmit. Alarm indication signal (AIS) is being...
Page 569
Problems with trunk cartridges service / 569 P0992638 03Modular ICS 6. 0 Installer Guide If through-fed repeaters are used on the T1 span, disable the internal CSU and connect the DTI to an external CSU. 6. If the problem persists, replace the DTI. Monitoring the T1 or PRI signal If you are finding minimal faults with the T1 or PRI signal, you can monitor the signal to try and isolate the problem. The monitor jack on the DTI faceplate provides non-intrusive, bridged in-service monitoring of the T1 or...
Page 570
570 / Problems with BRI service Modular ICS 6.0 Installer GuideP0992638 03 Problems with BRI service Each LED on front of a BRI-ST or BRI-U Card corresponds with a loop, or indicates an overall state of the BRI connections. The BRI card is connected to the ISDN network (U loop) but the LED for one of more loops is not lit Possible problem The physical connection or configuration for the network connection is not correct (no Layer 1). Solution 1. Verify the wiring from the network to the distribution...