Nortel Modular Ics 6.0 Installer Guide
Here you can view all the pages of manual Nortel Modular Ics 6.0 Installer Guide. The Nortel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 571
Problems with BRI service / 571 P0992638 03Modular ICS 6. 0 Installer Guide 5. Verify that the loop is provisioned. 6. Verify that the loop is properly configured, including the proper loop type, SPIDs, and Network DNs. 7. Disable and re-enable the BRI Card. 8. Disable and enable the module for the Card. Out of service displays when a BRI is selected (LED for loop is lit) Possible problem The loop is configured incorrectly. Layer 1 is present but Layers 2 and 3 are not working. Solution 1. Verify that...
Page 572
572 / Problems with BRI service Modular ICS 6.0 Installer GuideP0992638 03 Possible problem The card is not recognized by the ICS. Solution 1. Verify that an Expansion Cartridge with Clocking, or Clocking Cartridge is installed in the ICS. 2. Replace the card with another card of the same type. Caller hears one ring and then a fast busy signal when placing a call on a BRI line Possible problem CACH or EKTS, which are not supported by Modular ICS, is included in the ISDN services package. Solution 1....
Page 573
ICS down / 573 P0992638 03Modular ICS 6. 0 Installer Guide ICS down 1. If AC power is present and the LED indicator on the ICS is off, replace the ICS power supply. 2. Disconnect all central office and station lines from the ICS. Power down the ICS by unplugging it. Replacing the ICS power supply ❶ ❷
Page 574
574 / Trunk or Station Module down Modular ICS 6.0 Installer GuideP0992638 03 Trunk or Station Module down 1. Run a Maintenance session to ensure that the Trunk Module is not disabled. See Module status on page 495. 2. Disable the module using the Maintenance heading Module status. 3. Enable the module using the Maintenance heading Module status. 4. For Trunk Module Check the external line by terminating a single-line telephone directly on the distribution block, or equivalent, which connects to the...
Page 575
Data Module down / 575 P0992638 03Modular ICS 6. 0 Installer Guide Data Module down 1. Run a Maintenance session to ensure that the module is not disabled. See Module status on page 495. 2. Disable the Data Module using Module status. 3. Enable the Data Module using Module status. 4. If the Data Module is still down, power down, then power up the ICS and the Data Module. If the problem persists 1. If AC power is present and the LED indicator on the Data Module is off, replace the Data Module. 2....
Page 576
576 / Problems for network or remote users Modular ICS 6.0 Installer GuideP0992638 03 Problems for network or remote users Remote feature code gets no response Possible problem A Norstar user has called into another Norstar system and is trying to activate a remote feature but gets no response after dialing the feature code. Solution 1. Make sure that the remote caller is dialing the feature code correctly. Use the asterisk (*) character, followed by the feature code, to activate a remote feature....
Page 577
Problems for network or remote users / 577 P0992638 03Modular ICS 6. 0 Installer Guide 2. Verify all the digit strings that the switch should be sending. 3. Check that you have defined the corresponding Received number for every target line in your system. 4. Make sure that the published telephone numbers for your network are correct. Dialed number gets stuttered dial tone instead of ringback Possible problem The remote caller has tried to reach a Norstar target line, but has reached a trunk with...
Page 578
578 / Problems for network or remote users Modular ICS 6.0 Installer GuideP0992638 03 Dialed number gets dial tone instead of ringback Possible problem The remote caller has tried to reach a Norstar target line, but has reached the Norstar system instead. Norstar has mapped the incoming digits onto the Auto DN. Solution 1. Verify all the digit strings that the switch should be sending. 2. Check that you have defined the corresponding Received number for every target line in your system. 3. Check that...
Page 579
Problems for network or remote users / 579 P0992638 03Modular ICS 6. 0 Installer Guide Dialed number does not get through Possible problem The digits sent by a switch at a central office or in the private network did not match any Received number, the Auto DN, or the DISA DN. There is also no prime telephone assigned for the incoming trunk. In this case, the caller may hear overflow tone from the Norstar system or a recorded message from the originating switch. Solution 1. Configure a prime...
Page 580
580 / Problems for network or remote users Modular ICS 6.0 Installer GuideP0992638 03 3. If the switch at the far end is sending pulse signals, make sure they are being sent at the proper rate. Pulse digits must be 300 ms or more apart for Norstar to receive them. Possible problem If remote callers are having difficulty getting through from the public network, there may be a problem with your DID Trunk Cartridge. Solution 1. Connect a single-line DTMF telephone to a DID trunk input on the DID Trunk...