Page 71
Features and Specifications Manual A16 – 61 Doc. No. 8201 - Release 1.0 July 2003 Authorisation CodeA-16 FEATURE DESCRIPTIONAuthorisation Code permits a station to dial outside numbers that would otherwise be restricted. When an access code plus Authorisation Code is dialled, the station code restriction class temporarily changes to allow calls when permitted by a new code restriction class. The Authorisation Code can be verified or unverified based on class of service and is assigned in the...
Page 72
July 2003 NEC Business Solutions Ltd 62 – A16Authorisation Code Doc. No. 8201 - Release 1.0 July 2003 5. Press N to enter the information. The next Account Number is displayed. Repeat steps 4~5 until all desired Account Codes are entered. 6. Press P to stop entering Forced Account Codes/Authorisation Codes. SERVICE CONDITIONS Verified or Unverified for the Forced Account Code/Authorisation Code features. Memory Block 1-8-08 (Class of Service (Station) Feature Selection 2), Page 6, LK 3 is used to...
Page 73
Xen IPK Features and Specifications Manual Features and Specifications Manual A16 – 63 Doc. No. 8201 - Release 1.0 July 2003 Existing restrictions (permitted by the temporary change to code restriction class) and Least Cost Routing (LCR) assignments are applied after Forced Account Codes/Authorisation Codes are entered. Verified and Unverified Forced Account Code/Authorisation Code cannot be used in the same Class of Service. RELATED FEATURES LIST GUIDE TO FEATURE PROGRAMMINGFeature NumberFeature...
Page 74
July 2003 NEC Business Solutions Ltd 64 – A16Authorisation Code Doc. No. 8201 - Release 1.0 July 2003 ¶+ASPrinter Connected Selection 1-5-13 ¶+AS Printer Line Feed Control Selection 1-5-14 ¶+ASSMDR Incoming/Outgoing Print Selection 1-5-26 ¶+ASSMDR Valid Call Time Assignment 1-5-25 ¶+ASSMDR Print Format 1-5-02 ¶+ASSMDR Telephone Print Selection 4-56 ¶+CSSCOM Port Baud Rate Setting Assignment 1-8-35 ¶+BMStart Time Selection 1-1-05 4When the system is at default this Memory Block must be programmed for the...
Page 75
Features and Specifications Manual A17 – 65 Doc. No. 8201 - Release 1.0 July 2003 Automatic Answer with Delay Message A-17 FEATURE DESCRIPTIONThe Automatic Answer with Delay Message feature answers incoming CO/ PBX calls and plays a specified message to the outside caller while still ringing designated stations. Up to two messages can be played to the outside caller. The message(s) played are the same as the Automated Attendant message(s). SYSTEM AVAILABILITYTerminal Type Not applicable. Required...
Page 76
July 2003 NEC Business Solutions Ltd 66 – A17 Automatic Answer with Delay Message Doc. No. 8201 - Release 1.0 July 2003 1. Press T. 2. Dial HA. 3. Dial the incoming trunk number ( 00~FD). [00 = All CO/ PBX lines]. Note:Dialling 00 sets or cancels the Automated Attendant mode for all trunks when the trunks are idle. If a trunk is busy when 00 is dialled, it is not set. To set the Automated Attendant to a busy trunk, dial the individual trunk number. 4. Press T. 1. Press T. 2. Dial HB. 3. Dial the...
Page 77
Xen IPK Features and Specifications Manual Features and Specifications Manual A17 – 67 Doc. No. 8201 - Release 1.0 July 2003 1. Receive an incoming CO/PBX call. 2. The Automatic Answer with Delay Message answers the call and sends a greeting. 3. The outside party hears ringback tone or MOH (System Programmable). 4. After the time expires, a second message is played. 5. The outside party hears ringback tone or MOH until the call is answered. SERVICE CONDITIONSData Assignment A maximum of eight VRS(4)-U(...
Page 78
July 2003 NEC Business Solutions Ltd 68 – A17 Automatic Answer with Delay Message Doc. No. 8201 - Release 1.0 July 2003 General The Automatic Answer with Delay Message features uses the Automated Attendant Message to play to the outside caller. DIT/ANA assigned to the same trunk has higher priority. Automated Attendant and system Access Codes can be assigned individually. Automated Attendant assignment is assigned to tenants and follows the tenants Day/Night/Weekend mode switching. If Automated...
Page 79
Xen IPK Features and Specifications Manual Features and Specifications Manual A17 – 69 Doc. No. 8201 - Release 1.0 July 2003 ¶+AU4Automated Attendant Delay Announcement Assignment1-4-18 ¶+AU 4Automated Attendant 1st to 2nd Delay Announcement Interval Time1-4-19 ¶+AU 4Automated Attendant Delay Announcement Disconnect Time1-4-20 ¶+BCT4Trunk Incoming Answer Mode Selection3-05 ¶+AUAutomated Attendant Message to Trunk Selection 3-38 ¶+AU4Automated Attendant Function Selection3-59 ¶+BA4Access Code (1-, 2-,...