Home > NEC > Communications System > NEC Neax2000 Ivs Feature Programming Manual

NEC Neax2000 Ivs Feature Programming Manual

Here you can view all the pages of manual NEC Neax2000 Ivs Feature Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 341

CHAPTER 2 ND-45670 (E)
Pag e 3 20
Revision 2.0
NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
PROGRAMMING 
DESCRIPTION DATA
Assign a Trunk Restriction Class to each 
station. •  YY = 01
 (1)  X-XXXX (Station No.) 
 (2)  XX
*a: Trunk Restriction Class in Night 
Mode (1-7) 
1 : Unrestricted (RCA) 
2: Non-Restricted 1 (RCB) 
3: Non-Restricted 2 (RCC) 
4: Semi-Restricted 1 (RCD) 
5: Semi-Restricted 2 (RCE) 
6: Restricted 1 (RCF) 
7: Restricted 2 (RCG) 
Assign the Class of Service for TAS to the 
required...

Page 342

ND-45670 (E) CHAPTER 2
Page 321
Revision 2.0
NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
DESCRIPTION DATA
Specify the function of each type of TAS 
within a system.•  Y = 0-4 (TAS Answer A-E) 
 (1)  Type of Call
1: C.O. Incoming Call 
2: Tie Line/DID 
3: C.O. Incoming Call in Night Mode 
4: Overflowed DIT Call
 (2)  0/1 : Cannot be answered/Can be an-
swered 
 (1)  7: A call terminated to a different ten-
ant.
 (2)  0/1 : Can be answered 
Assign the access code for each type of TAS 
(TAS Answer A-E)...

Page 343

CHAPTER 2 ND-45670 (E)
Pag e 3 22
Revision 2.0
NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
To provide the External TAS Indicator using the PN-DK00 card:
To provide the Telephone set for TAS Indication using the PN-4LC card:DESCRIPTION
DATA
Assign the PN-DK00 card No. to the required 
LEN. (1)  LEN (0000-0511) 
 (2)  E800-831 (PN-DK00 Card No.) 
For PIM0/1: E800-E807 
For PIM2/3: E808-E815 
For PIM4/5: E816-E823 
For PIM6/7: E824-E831 
Assign the TAS Group No. assigned by 
CM30 YY = 17 to the circuit...

Page 344

ND-45670 (E) CHAPTER 2
Page 323
Revision 2.0
NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
HARDWARE REQUIRED 
To provide the External TAS Indicator: 
• PN-DK00
• Indicator 
Requirement for External Indicator
Control Method: Ground/Battery (-24 V) (Max.125 mA) 
Type:  Visual and/or Audible type with volume control
Make the following connections at the MDF according to the type of the indicator. For details, refer to the MDF
cross connection for a TAS Indicator in the INSTALLATION PROCEDURE MANUAL.
To...

Page 345

CHAPTER 2 ND-45670 (E)
Pag e 3 24
Revision 2.0
OFF-HOOK ALARM
PROGRAMMING
DESCRIPTION DATA
Provide this feature for the required stations.  •  YY = 02
(1) X-XXX (Station No.) 
(2)  0: To be provided 
Assign the destination for Off-Hook Alarm 
to a Station or SN610 ATTCON. •  YY = 12 
(1)  Tenant No. (00-63) 
(2) X-XXXX (Station No.) 
E000: SN610 ATTCON
If the Attendant Console is designated as the 
destination of Off-Hook Alarm by CM51 YY 
= 12, assign an EMG key for the Off-Hook 
Alarm to any Key. •  YY...

Page 346

ND-45670 (E) CHAPTER 2
Page 325
Revision 2.0
OFF PREMISES EXTENSION
PROGRAMMING 
HARDWARE REQUIRED 
PN-AUCA card
DESCRIPTION DATA
Remove the PAD on Off Premises Extension.  •  YY  =  09
 (1)  X-XXXX (Station Number) 
 (2)  0: No PAD (6 dB) CM13 START
END 

Page 347

CHAPTER 2 ND-45670 (E)
Pag e 3 26
Revision 2.0
PAD LOCK (1300 Series Enhancement)
PROGRAMMING
1. In case of a system with AP card (PN-AP01):
DESCRIPTION DATA
Assign the slot number to AP card
Note:Set SENSE switch on the card to the
slot number assigned(1) Slot No. (04-15)
(2) 07: PN-AP01 card
Designate the AP card for Authorization 
Code.(1) 216:Designation of Processor for Autho-
rization Code
(2) 1 : AP (PN-AP01)
Specify the Service Set Tone after dialling the 
access code for Authorization Code.(1)...

Page 348

ND-45670 (E) CHAPTER 2
Page 327
Revision 2.0
PAD LOCK (1300 Series Enhancement)
DESCRIPTION DATA
Specify the maximum number of digits for 
Authorization Code.(1) 11:Authorization Code Max. digits
(2) Max. number of digits
01: 1 digit
08: 8 digits
NONE : 8 digits
Specify the conditions for adding Check Code 
to each Authorization Code.
Check Code consists of 2 digits: 1st and 2nd 
Check Code which are generated by the AP 
according to the conditions specified by Y=0 
and Y=1.
Authorization Code:
X
1 X2 X3...

Page 349

CHAPTER 2 ND-45670 (E)
Pag e 3 28
Revision 2.0
PAD LOCK (1300 Series Enhancement)
DESCRIPTION DATA
Set the Authorization Code and the Temporary
Service Class given by CM15. 
Service Restriction Class (B) of the Temporary
Service Class should be set to the allowed class
for Maid Status.
• Temporary Service Class.
2 X
2 X3 X4 X5 X6 X7 X8 X9
•
(1)
(2)Y=3
X-X...X: Authorization Code
2 X
2 ...X9 (9 digits)
(See column below)
2: Type of Temporary Service Class as per 
X
2...X9 
Trunk Restriction Class (01-08)...

Page 350

ND-45670 (E) CHAPTER 2
Page 329
Revision 2.0
PAD LOCK (1300 Series Enhancement)
DESCRIPTION DATA
Allow each Status Number (Restricted/
Normal) to change the Status Number from 
the station.
Note:Desired number can be assigned for
the Status Number of each status.(1) 1
 31
Status No. (Restricted) Note
Allowed to change the Status
No. from the station
(2) 1: Yes
(1) 2
 31
Status No. (Normal) Note
Allowed to change the Status
No. from the station.
(2) 1: Yes
Assign the originating function, the incoming...
Start reading NEC Neax2000 Ivs Feature Programming Manual

Related Manuals for NEC Neax2000 Ivs Feature Programming Manual

All NEC manuals