Page 291

CHAPTER 2 ND-45670 (E)
Pag e 2 70
Revision 2.0
LEAST COST ROUTING-3/6-DIGIT
Example: 
Conditions: 
(1) Order of LCR Selection: 
1st... Route 02 (FX) 
2nd... Route 01 (WATS) 
3rd... Route 00 (DDD)
(2)  Dialed Number:
9 – 212 – NXX – XXXX
*a: Access Code 
*b: Area Code 
*c: Office Code 
*d: Telephone Number
(3)  Toll Restriction Pattern: 
RCA RCB RCC RCD RCE
00 –––––
01 –––´´
02 – –´´´
9-212-
NXX-
XXXXRT00
RT01
RT02DDD
WATS
FXC.O. AREA CODE
212NXX-XXXX
*b *a *c *d
–: Allowed
´: Restricted
CLASS
ROUTE 

Page 292

ND-45670 (E) CHAPTER 2
Page 271
Revision 2.0
LEAST COST ROUTING-3/6-DIGIT
Programming for Example 1:
Step 1
: Assign “9” to the access code of LCR Group 0 in Numbering Plan Group 0.
 + 200  +    + 9  +    +  A26  +    
Step 2
: Assign  Area Code Development Pattern No. 5 to LCR Group 0.
 + 8AA00  +    + 0  +    +  5  +    
Step 3
: Assign Route Pattern No. 00 to area code (212) for Area code Development Pattern No. 5.
 + 8A405  +    + 212  +    +  000  +    
Step 4
: In Route Pattern No. 00, specify the...

Page 293

CHAPTER 2 ND-45670 (E)
Pag e 2 72
Revision 2.0
LEAST COST ROUTING-3/6-DIGIT
Example: 
Conditions: 
(1) Order of LCR Selection: 
1st... Route 02 (FX) 
2nd... Route 01 (WATS) 
3rd... Route 00 (DDD)
(2)  Dialed Number:
• 9-214-232/236-XXXX 
Note:236 is a Toll Office.
• 9-213-NXX-XXXX 
(3)  Toll Restriction Pattern: 
Note:
 Area Code 213 is restricted.RCA RCB RCC RCD RCE
00 –––––
01 – –´´
02 –´´´
RT00
RT01
RT02DDD WATSFX
C.O.
AREA CODE 214
236
232
1-236-XXXX
213-NXX-XXXX
AREA 
CODE 
213
–: Allowed
´:...

Page 294

ND-45670 (E) CHAPTER 2
Page 273
Revision 2.0
LEAST COST ROUTING-3/6-DIGIT
Programming for Example 2:
Step 1
: Assign “9” to the access code of LCR Group 0 in Numbering Plan Group 0.
 + 200  +    + 9  +    +  A26  +    
Step 2
: Assign  Area Code Development Pattern No. 5 to LCR Group 0.
 + 8AA00  +    + 0  +    +  5  +    
Step 3
: Assign Route Pattern Nos. 00 and 01to area codes 214 and 213 respectively.
 + 8A405 +    + 214  +     +  000
  +   
Route Pattern No. 00
 + 8A405 +    + 213  +     +  001
  +...

Page 295

CHAPTER 2 ND-45670 (E)
Pag e 2 74
Revision 2.0
LEAST COST ROUTING-3/6-DIGIT
–: Allowed
´: Restricted
Step 5
: In LCR Pattern Nos. 000 and 003, delete the area code dialed.
 + 8A500
 +  + 151 +  + 0 +  
LCR Pattern No. 000 To be deleted
 + 8A503
 +  + 151 +  + 0 +  
LCR Pattern No. 003 To be deleted
Step 6
: Assign the Toll Restriction Pattern to each LCR Pattern No. For LCR Pattern No. 000:
 + 8A500
 +  + 000 +  + 01 +  
LCR Pattern No. 000 Toll Restriction Pattern No. specified by CM81.
For LCR Pattern...

Page 296

ND-45670 (E) CHAPTER 2
Page 275
Revision 2.0
LEAST COST ROUTING-3/6-DIGIT
Step 7: In LCR Pattern No. 000, designate the prefix “1”, in addition to the office code 236, by the six-digit Prefix 
Pattern.
• Designation of 6-digit Prefix Pattern No.
 + 8A500 +   +  150  +   + 00
 +  
6-digit Prefix Pattern No. 00
• Designation of office code requiring Prefix Pattern.
 + 8A800
 +  +  236  +   + 1 +   
6-digit Prefix Pattern No. 00
Step 8
:  Assign the maximum number of digits dialed. 
 + 855
 +  + 21 +  + 10...

Page 297

CHAPTER 2 ND-45670 (E)
Pag e 2 76
Revision 2.0
LINE LOCKOUT
PROGRAMMING
DESCRIPTION DATA
Provide the system with Howler Tone sent to 
locked-out stations, if required.(1) 153
(2)  0/1 : Not provide/Provide
If Howler Tone is provided (CM08-153 = 1), 
set this feature to the required stations.•  YY = 04
(1) X-XXXX (Station No.)
(2)  1 : Provide
Specify the timing for Line Lockout. •  Y = 0
(1) 22
(2)  01-08: 4-32 sec. in 4 sec. increments
If no data is set, the default setting is 28-32
seconds.
Specify the...

Page 298

ND-45670 (E) CHAPTER 2
Page 277
Revision 2.0
LINE PRESELECTION
PROGRAMMING 
DESCRIPTION DATA
Specify the operation of Line Preselection on 
a Multiline Terminal. (1) 199 
(2)  0 : Only desired line key. 
1 : SPKR key is required after 
pressing the desired line key.
START
END
CM08 

Page 299

CHAPTER 2 ND-45670 (E)
Pag e 2 78
Revision 2.0
MAINTENANCE ADMINISTRATION TERMINAL (MAT)
PROGRAMMING
To provide password service for the MAT:
DESCRIPTION DATA
Specify the command codes accessible to 
each Password Level.•  YY = 00: Password Level 0-6 
•  YY = 01: Password Level 1-6 
•  YY = 02: Password Level 2-6 
•  YY = 03: Password Level 3-6 
•  YY = 04: Password Level 4-6 
•  YY = 05: Password Level 5-6 
•  YY = 06: Password Level 6 
•  YY = 10: Password Level 0 
•  YY = 11: Password Level 1 
•  YY =...

Page 300

ND-45670 (E) CHAPTER 2
Page 279
Revision 2.0
MAINTENANCE ADMINISTRATION TERMINAL (MAT)
Note:If the Password Service is provided, enter a password predetermined by CM03 before programming from
the MAT.
 + 03 +     +  Password Level No. (0-7)    +     +   Password +    
- “OK” will be displayed, if accepted. 
- “DATA ERROR” will be displayed if the password is incorrect. ST
DEDEEXE 