Page 201

NEAX2400 IPX Feature Programming ManualPage 158NDA-24297, Issue 1
C-10 Call Transfer - Attendant
C-10  Call Transfer - Attendant
General Description
This feature permits a user, while connected to an exchange network call, to signal the Attendant and have the
Attendant transfer the call to another station within the system.
Operating Procedure
Calling the Attendant
1. While engaged in a Central Office trunk call, press the switch hook; receive special dial tone.
2. Dial the operator access code.
a.)...

Page 202

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 159
Call Transfer - Attendant C-10
Interactions (cont’d)
7. A CALL TRANSFER to a station with CALL FORWARDING [C-2, 3, 5] set will forward according to
the conditions of the feature set, unless the station is set to CALL FORWARD - ALL CALLS [C-5] to the
Attendant Console. CALL FORWARDING-OVERRIDE [C-26] supersedes CALL FORWARDING-
ALL CALLS [C-5].
8. A CALL TRANSFER to a station in a STATION HUNTING [S-7, 8, 9] group will hunt according to...

Page 203

NEAX2400 IPX Feature Programming ManualPage 160NDA-24297, Issue 1
C-11 Call Transfer - All Calls
C-11  Call Transfer - All Calls
General Description
This feature permits a user to transfer incoming or outgoing Central Office and intra-office calls to another station
within the system without Attendant assistance.
The user can set Camp-on function to the busy destination while transferring an incoming call (Camp-on by Station).
With this feature, the trunk party is called back directly, as the destination...

Page 204

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 161
Call Transfer - All Calls C-11
Service Conditions
1. The station performing the CALL TRANSFER - ALL CALLS can drop off the connection before the
called party answers. If the called station does not answer within the predetermined time, ringing signal is
returned to the transferring station. See VARIABLE TIMING PARAMETERS[V-1]for other selectable
timing choices.
2. In the case of outgoing calls (no answer supervision), this feature may be...

Page 205

NEAX2400 IPX Feature Programming ManualPage 162NDA-24297, Issue 1
C-11 Call Transfer - All Calls
Service Conditions (cont’d)
15. The Camp-on by Station is not available for the target station in LINE LOCKOUT [L-3] condition.
16. The Camp-on by Station is not available in the following cases:
a.) When the transferred station is dialing the number.
b.) When a call is terminating to the transferred station (the station is ringing).
c.) When the transferred station hears busy tone or reorder tone.
d.) When...

Page 206

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 163
Call Transfer - All Calls C-11
Interactions (cont’d)
2. See TRUNK-TO-TRUNK CONNECTION[T-10]for additional programming if the call is to be
transferred off network.
3. If a station is in an established THREE-WAY CALLING [T-2] connection, that station cannot activate
any features. If a station switch hook flashes to activate a feature, the flash is ignored and the three-way
connection remains established.
4. Features that cannot be...

Page 207

NEAX2400 IPX Feature Programming ManualPage 164NDA-24297, Issue 1
C-11 Call Transfer - All Calls
Programming
STEP 1:ASYD- SYS2, Index 0, bit 0 = 1 (Allow the restriction for Call Back service)
SYS2, Index 5, bit 2. Camp-on by Station is set automatically after the operating station is released
from the connection after encountering the busy target station.
0 = No (Recall to the mediate station)
1 = Yes (Camp On service is set)
SYS2, Index 10, bit 7. Number of time(s) that the warning tone (Call Waiting...

Page 208

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 165
Call Transfer - All Calls - DtermC-11D
C-11D  Call Transfer - All Calls - Dterm
General Description
This feature permits a Dtermuser to transfer incoming or outgoing calls without Attendant assistance.
The D
termuser can set Camp-on function to the busy destination while transferring an incoming call (Camp-on by
Station). With this feature, the trunk party is called back directly as the destination becomes idle.
Operating Procedure
To...

Page 209

NEAX2400 IPX Feature Programming ManualPage 166NDA-24297, Issue 1
C-11D Call Transfer - All Calls - Dterm
Operating Procedure (cont’d)
3. Method of operation:
a.) When the access code is used, press the FLASH key; receive special dial tone and no indication
on the LCD display, then dial the access code of CALL BACK; receive service set tone.
b.) When the feature key/soft key is used, press the CALL BACK key; receive service set tone. The
LCD of the operating station displays as mentioned above in the way...

Page 210

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 167
Call Transfer - All Calls - DtermC-11D
Operating Procedure (cont’d)
2. Dial the third party, and the third party is busy; receive busy tone. The LCD of the operating station
displays:
                                   The extension number of the third party
3. Replace the handset. The station to be set Camp-on by Station hears Warning Tone. The LCD of the
operating party displays:
The LCD display is changed after the trunk receives...