NEAX2400 IPX Feature Programming ManualPage 88NDA-24297, Issue 1
B-6 Brokerage - Hotline
B-6  Brokerage - Hotline
General Description
This feature provides a HOT LINE [H-1] function for Dterm.
Operating Procedure
To access from Dterm
1. Lift handset or press the SPEAKER key.
2. Press sub-line key associated with the predetermined desired station. The destination station is
automatically dialed; Ringback tone is heard, the destination station answers.
3. After completion of conversation, hang up or press...

Page 132

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 89
Brokerage - Hotline B-6
Service Conditions (cont’d)
the destination station is off-hook.
the destination station is already engaged in a three-party call.
c.) the destination is the Attendant or is connected to an outside party.
16. When EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] is used with this feature, it is not activated under any
of the following conditions:
when utilizing EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] service using switch hook flash...

Page 133

NEAX2400 IPX Feature Programming ManualPage 90NDA-24297, Issue 1
B-6 Brokerage - Hotline
Programming (cont’d)
STEP 3:AKYD-AssigntoaDterma line appearance of the Hotline station number.
TN: 1
STN: Station Number
TP: Type of D
term(0/1)
KYN: Key Number (1-40)
KYI: Service Index
0: Key not used
1: Feature Key
2: Multi-line Key
KD: 0
TN, STN: Tenant Number and Station Number of Multi-line (Virtual)
RG: Ringing Assignment per Multi-Line Appearance
0: No Ringing
1: Ringing in Day Mode Only
2: Ringing in Night...

Page 134

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 91
Boss - Secretary - Message Waiting Lamp Control B-8
B-8 Boss - Secretary - Message Waiting Lamp Control
General Description
This feature allows a secretary, via her station, to control the Call Indicator LampNote or Message Waiting (MW)
display on the boss station.
Note:The Call Indicator Lamp is used as the MW Lamp.
Operating Procedure
1. CALL FORWARDING [C-3, 5] is not set on Boss station.
2. An incoming call for Boss station is answered...

Page 135

NEAX2400 IPX Feature Programming ManualPage 92NDA-24297, Issue 1
B-8 Boss - Secretary - Message Waiting Lamp Control
Service Conditions (cont’d)
5. This feature is not restricted by CLASS OF SERVICE - INDIVIDUAL [C-15] on either the boss or
secretary stations.
6. BOSS-SECRETARY MW LAMP CONTROL indication is cleared by system initialization or a Local
Processor initialization.
7. MW control is provided to stations using the D
termsub-line when:
a.) one station is talking with another station.
b.) a...

Page 136

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 93
Boss - Secretary - Message Waiting Lamp Control B-8
Service Conditions (cont’d)
d.) MUSIC ON HOLD [M-7] when the other party has pressed the HOLD key.
e.) dialing of telephone number.
f.) trunk origination or called-number dialing.
g.) calls to or talking to Attendant.
h.) THREE-WAY CALLING [T-2].
i.) CONSULTATION HOLD - ALL CALLS [C-17].
j.) calls by VOICE CALL - D
term[V-2D].
k.) Call Waiting ringback tone with Call Waiting set.
l.)...

Page 137

NEAX2400 IPX Feature Programming ManualPage 94NDA-24297, Issue 1
B-8 Boss - Secretary - Message Waiting Lamp Control
Programming
STEP 1:AKYD- Assign to a programmable line/feature key a MW Lamp Set key; Type:Function:BOSS-
SECRETARY MSG WAIT-SET [9] and a MW Lamp Cancel key; Type:Function:BOSS-
SECRETARY MSG WAIT-CNCL [11].
STEP 2:ADSL- Assign SN=4 (Communication in Progress) when operating Procedure 1, SN=2 (Originating)
when operating Procedure 2. Assign FKY=9 (MW Lamp Set key; MWSET) and FKY=11 (MW...

Page 138

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 95
Boss - Secretary Transfer B-11
B-11  Boss - Secretary Transfer
General Description
This feature allows a secretary to voice-announce a call to a boss when the secretary answers a call to the boss line.
Operating Procedure
To transfer from Dterm to Dterm
1. Call terminates to Boss line.
2. Secretary answers the call on the sub-line of Secretarys D
term.
3. Secretary presses the line key of answered call; Boss and Secretary talk by Voice...

Page 139

NEAX2400 IPX Feature Programming ManualPage 96NDA-24297, Issue 1
B-11 Boss - Secretary Transfer
Service Conditions (cont’d)
4. This feature must be allowed in CLASS OF SERVICE - INDIVIDUAL [C-15] via system data
programming.
5. BOSS-SECRETARY TRANSFER [B-11] is denied if the secretary is connected to the ATTENDANT
CONSOLE [A-3].
6. If provided in the system, the held caller will hear MUSIC ON HOLD [M-7].
7. The call is recorded in SMDR [S-10] for the boss station.
8. This feature will override CALL...

Page 140

NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1Page 97
Brokerage Hotline - Outside B-12
B-12  Brokerage Hotline - Outside
General Description
This feature provides a HOT LINE - OUTSIDE [H-9] function for a Dterm.
Operating Procedure
To access a BROKERAGE HOT LINE - OUTSIDE from a Dterm
1. Lift the handset or press the SPEAKER key.
2. Press the sub-line key associated with a predetermined desired outside party. The destination station is
automatically dialed; ringback tone is heard; the...