Page 911

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 867
Executive Right-of-Way - CCIS E-8
E-8 Executive Right-of-Way - CCIS 
General Description
This service feature allows Inter-Office Executive Right-of-Way when the bridging-in station and the bridged
station respectively, belong to a different PBX in the CCIS network.
Operating Procedure
1. While Stations A and B are engaging in a call, Station C goes off-hook and receives dial tone. 
2. Station C dials the number for Station B and...

Page 912

NEAX2400 IMX Feature Programming Manual
Page 868ND-70184 (E), Issue 3
E-8 Executive Right-of-Way - CCIS
Operating Procedure (cont’d)
5. Station A hangs up; Stations C and B remain connected with each other until either or both go on-hook.
Service Conditions
1. Two burst tones are transmitted upon activation to alert connected parties that an EXECUTIVE override
connection is being made. 
2. EXECUTIVE Right-of-Way may be denied if the busy station is:
a.) Dialing or in LINE LOCKOUT [L-3]
b.) Listening to a...

Page 913

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 869
Executive Right-of-Way - CCIS E-8
Programming (cont’d)
STEP 4:ASFC - Assigns Executive Right-of-Way Calling (SFI = 3) to the SFC of the station setting Executive
Right-of-Way. Also assigns Executive Right-of-Way-Called (SFI = 4) and Attendant Camp-On (SFI =
11) to the SFC of the station to which Executive Right-of-Way is set. At the remote node, assign SFI 3,
4 and 11 to SFC 0.
STEP 5:AT R K - Assigns the trunk for 3-Way Calling...

Page 914

NEAX2400 IMX Feature Programming Manual
Page 870ND-70184 (E), Issue 3
E-9 Elapsed Time Display - CCIS
E-9 Elapsed Time Display - CCIS
General Description
This feature provides an LCD display of the time elapsed while a Dterm is connected to any trunk through the CCIS
network.
Operating Procedure
No manual operation is required.
Service Conditions
1. The elapsed time is displayed in the eight left-side positions of the LCD display.
2. The elapsed time can reach a maximum of 9 hours, 59 minutes and 59...

Page 915

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 871
E911 - ANI Unified Number of Digits - CCIS E-20
E-20  E911 - ANI Unified Number of Digits - CCIS
General Description
This feature allows a station or Attendant Console, called via CCIS, to perform E911-ANI service. This feature is
functionally identical to AUTOMATIC NUMBER IDENTIFICATION (ANI) [A-87]. 
Operating Procedure
The operating procedure is the same as that of a normal outgoing connection.
Service Conditions 
1. This feature...

Page 916

NEAX2400 IMX Feature Programming Manual
Page 872ND-70184 (E), Issue 3
E-20 E911 - ANI Unified Number of Digits - CCIS
Service Conditions (cont’d)
 If OG call is from an ATTCON and Individual ATT Access Code is assigned, and also ANI
data is assigned:
KP-0
-N**-****-ST
  If OG call is from an ATTCON and Individual ATT Access Code is unassigned, and ANI data
is assigned:
KP-0
-N**-****-ST
 If OG call is from an ATTCON and ANI data is unassigned:
KP-1
- ST
b.) Outgoing call from station/Attendant Console...

Page 917

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 873
E911 - ANI Unified Number of Digits - CCIS E-20
Service Conditions (cont’d)
The COC digit is 82; then assign ANI information. 
Example 2:
Office number: 826
Station number: 34xxx, 4xxx 
The COC digit is 826; then assign ANI information.
11. After digits have been sent out, DDD seizure tone is not sent. 
12. Other interactions are the same as those of outgoing calls by MF signalling. 
13. An 8RST-K circuit card is used for this...

Page 918

NEAX2400 IMX Feature Programming Manual
Page 874ND-70184 (E), Issue 3
F-12 Flexible Numbering of Stations - CCIS
F-12  Flexible Numbering of Stations - CCIS 
General Description
This feature allows voice and data station numbers to be assigned to any instrument in the CCIS network, based
solely on numbering plan limitations.
Operating Procedure
Refer to the NEAX2400 IMX Office Data Specification.
Service Conditions
1. Careful consideration should be given to the network numbering plan to avoid needless...

Page 919

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 875
Hands-free Answerback - Dterm - CCIS H-10D
H-10D Hands-free Answerback - Dterm - CCIS 
General Description
This feature allows a Dterm user to respond to a VOICE CALL - CCIS [V-7] without lifting the handset.
Operating Procedure
To answer:
1. Lift the handset and press the line key to answer the call. 
2. Press feature key and “1; the MIC LED lights. 
3. Press feature key and “5” to select hands-free operation. 
4. Replace the...

Page 920

NEAX2400 IMX Feature Programming Manual
Page 876ND-70184 (E), Issue 3
H-11 House Phone - CCIS
H-11  House Phone - CCIS
General Description
This feature allows selected stations to call an Attendant Console through the CCIS network, simply by going off-
hook.
Operating Procedure
To call the Attendant:
1. The HOUSE PHONE - CCIS user lifts the handset.
2. The Attendant is automatically called.
Service Conditions
1. Attendant Console indications will appear as follows: 
a.) ATND lamp flashes.
b.) Console...