Page 911
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 867 Executive Right-of-Way - CCIS E-8 E-8 Executive Right-of-Way - CCIS General Description This service feature allows Inter-Office Executive Right-of-Way when the bridging-in station and the bridged station respectively, belong to a different PBX in the CCIS network. Operating Procedure 1. While Stations A and B are engaging in a call, Station C goes off-hook and receives dial tone. 2. Station C dials the number for Station B and...
Page 912
NEAX2400 IMX Feature Programming Manual Page 868ND-70184 (E), Issue 3 E-8 Executive Right-of-Way - CCIS Operating Procedure (cont’d) 5. Station A hangs up; Stations C and B remain connected with each other until either or both go on-hook. Service Conditions 1. Two burst tones are transmitted upon activation to alert connected parties that an EXECUTIVE override connection is being made. 2. EXECUTIVE Right-of-Way may be denied if the busy station is: a.) Dialing or in LINE LOCKOUT [L-3] b.) Listening to a...
Page 913
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 869 Executive Right-of-Way - CCIS E-8 Programming (cont’d) STEP 4:ASFC - Assigns Executive Right-of-Way Calling (SFI = 3) to the SFC of the station setting Executive Right-of-Way. Also assigns Executive Right-of-Way-Called (SFI = 4) and Attendant Camp-On (SFI = 11) to the SFC of the station to which Executive Right-of-Way is set. At the remote node, assign SFI 3, 4 and 11 to SFC 0. STEP 5:AT R K - Assigns the trunk for 3-Way Calling...
Page 914
NEAX2400 IMX Feature Programming Manual Page 870ND-70184 (E), Issue 3 E-9 Elapsed Time Display - CCIS E-9 Elapsed Time Display - CCIS General Description This feature provides an LCD display of the time elapsed while a Dterm is connected to any trunk through the CCIS network. Operating Procedure No manual operation is required. Service Conditions 1. The elapsed time is displayed in the eight left-side positions of the LCD display. 2. The elapsed time can reach a maximum of 9 hours, 59 minutes and 59...
Page 915
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 871 E911 - ANI Unified Number of Digits - CCIS E-20 E-20 E911 - ANI Unified Number of Digits - CCIS General Description This feature allows a station or Attendant Console, called via CCIS, to perform E911-ANI service. This feature is functionally identical to AUTOMATIC NUMBER IDENTIFICATION (ANI) [A-87]. Operating Procedure The operating procedure is the same as that of a normal outgoing connection. Service Conditions 1. This feature...
Page 916
NEAX2400 IMX Feature Programming Manual Page 872ND-70184 (E), Issue 3 E-20 E911 - ANI Unified Number of Digits - CCIS Service Conditions (cont’d) If OG call is from an ATTCON and Individual ATT Access Code is assigned, and also ANI data is assigned: KP-0 -N**-****-ST If OG call is from an ATTCON and Individual ATT Access Code is unassigned, and ANI data is assigned: KP-0 -N**-****-ST If OG call is from an ATTCON and ANI data is unassigned: KP-1 - ST b.) Outgoing call from station/Attendant Console...
Page 917
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 873 E911 - ANI Unified Number of Digits - CCIS E-20 Service Conditions (cont’d) The COC digit is 82; then assign ANI information. Example 2: Office number: 826 Station number: 34xxx, 4xxx The COC digit is 826; then assign ANI information. 11. After digits have been sent out, DDD seizure tone is not sent. 12. Other interactions are the same as those of outgoing calls by MF signalling. 13. An 8RST-K circuit card is used for this...
Page 918
NEAX2400 IMX Feature Programming Manual Page 874ND-70184 (E), Issue 3 F-12 Flexible Numbering of Stations - CCIS F-12 Flexible Numbering of Stations - CCIS General Description This feature allows voice and data station numbers to be assigned to any instrument in the CCIS network, based solely on numbering plan limitations. Operating Procedure Refer to the NEAX2400 IMX Office Data Specification. Service Conditions 1. Careful consideration should be given to the network numbering plan to avoid needless...
Page 919
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 875 Hands-free Answerback - Dterm - CCIS H-10D H-10D Hands-free Answerback - Dterm - CCIS General Description This feature allows a Dterm user to respond to a VOICE CALL - CCIS [V-7] without lifting the handset. Operating Procedure To answer: 1. Lift the handset and press the line key to answer the call. 2. Press feature key and “1; the MIC LED lights. 3. Press feature key and “5” to select hands-free operation. 4. Replace the...
Page 920
NEAX2400 IMX Feature Programming Manual Page 876ND-70184 (E), Issue 3 H-11 House Phone - CCIS H-11 House Phone - CCIS General Description This feature allows selected stations to call an Attendant Console through the CCIS network, simply by going off- hook. Operating Procedure To call the Attendant: 1. The HOUSE PHONE - CCIS user lifts the handset. 2. The Attendant is automatically called. Service Conditions 1. Attendant Console indications will appear as follows: a.) ATND lamp flashes. b.) Console...