Page 837
Centralized Maintenance - CCIS C-167
C-167 Centralized Maintenance - CCIS
          (Series 7400 software feature)
General Description
This FCCS service allows all nodes (NEAX2400 IMX systems) in the multiple FCCS groups (networks where
multiple NEAX2400 IMXs are connected via FCCS link) and NEAX2000 IVS systems, connected via CCIS link,
to be maintained from a single MAT. The MAT used for this feature is called Centralized MAT.
Note:...

Page 882

NEAX2400 IMX Feature Programming Manual
Page 838ND-70184 (E), Issue 3
C-167 Centralized Maintenance - CCIS
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Assign the following data at the NCN in each FCCS group (FUG)
STEP 1:AFUGN - Assign...

Page 883

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 839
Centralized Maintenance - CCIS C-167
FCCS Programming (cont’d)
 To connect FUG and a NEAX2000 IVS (refer to the manuals for the NEAX2000 IVS for data
programming on the NEAX2000 IVS side):
 To connect a NEAX2400 IMX and a NEAX2400 IMX (NEAX2400 IMX stands for the FCCS node
working alone in an FCCS network):
Center FUGFPC 1
PC 1
FUG 1
FPC 3
PC 3
NCN
FPC 2
PC 2CCIS
-
-
- -
-
- -
-
--
-
-
NEAX2000 
IVS
Center FUGFPC 1
NCN
PC 4
FPC 4 PC...

Page 884

NEAX2400 IMX Feature Programming Manual
Page 840ND-70184 (E), Issue 3
D-41 Data Communication - CCIS
D-41  Data Communication - CCIS
General Description
This service allows Inter-Office data communication service where the Digital Interface (DTI) is used as the CCIS
Line over a T1 channel (Digital Link Channel). 
With this service, the data communication line between synchronous and asynchronous terminals can be directly
connected to the DTI without using the MODEM Pooling or a DST card.
Operating...

Page 885

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 841
Data Communication - CCIS D-41
Operating Procedure (cont’d)
When cancelling the data connection: 
1. Press the DATA key on Dterm (a); the LCD of Dterm (a) restores the display of Time and Date.
Note:
If the opposite DTE is released, the buzzer on the Data Module/Data Adapter sounds three times.
Enter Release command RLS RETURN from the keyboard of the DTE. RLS and RELEASED are displayed on the
monitor screen. The data connection has...

Page 886

NEAX2400 IMX Feature Programming Manual
Page 842ND-70184 (E), Issue 3
D-65 Data Interface - Automatic Answer - CCIS
D-65  Data Interface - Automatic Answer - CCIS 
General Description
This feature allows a data terminal to automatically answer an incoming CCIS call without manual operation,
therefore, providing the capability of receiving electronic mail.
Operating Procedure
To activate AUTOMATIC ANSWER for terminating data calls, Automatic Answer Mode can be set by any of
the following methods:
1. Set...

Page 887

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 843
Data Interface - Automatic Answer - CCIS D-65
Programming (cont’d)
KYI: Service Index
0: Key Not Used 
1: Feature Key
2: Multi-line Key 
KD: Not assigned for Feature Key
FKY: Feature Key Number
FKY = 30, AUTOMATIC ANSWER 

Page 888

NEAX2400 IMX Feature Programming Manual
Page 844ND-70184 (E), Issue 3
D-66 Data Line Security - CCIS
D-66  Data Line Security - CCIS 
General Description
This feature allows line circuits used for data transmission to be protected from interruptions, such as,
ATTENDANT CAMP-ON WITH TONE INDICATION - CCIS [A-45], BUSY VERIFICATION - CCIS [B-9],
EXECUTIVE RIGHT-OF-WAY - CCIS [E-8], and ATTENDANT OVERRIDE [A-7].
Operating Procedure
No manual operation is required.
Service Conditions 
1. If an Attendant or...

Page 889

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 845
Data Line Privacy - CCIS D-67
D-67  Data Line Privacy - CCIS 
General Description
This feature automatically prevents interruptions from features such as ATTENDANT CAMP-ON WITH TONE
INDICATION - CCIS [A-45], BUSY VERIFICATION - CCIS [B-9], and EXECUTIVE RIGHT-OF-WAY - CCIS
[E-8] during data transmission through the CCIS network.
Operating Procedure
Data Connection (Dterm-Data Adapter/Data Module): No manual operation is required. When...

Page 890

NEAX2400 IMX Feature Programming Manual
Page 846ND-70184 (E), Issue 3
D-68 Data Privacy on Demand - CCIS
D-68  Data Privacy on Demand - CCIS
General Description
This feature allows a user to prevent interruptions by features such as ATTENDANT CAMP-ON - CCIS [A-45],
BUSY VERIFICATION - CCIS [B-9], and EXECUTIVE RIGHT-OF-WAY - CCIS [E-8] during data transmission
through the CCIS network by dialing a DATA PRIVACY feature code.
When the incoming call cannot be restricted since data communication is...