NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 837 Centralized Maintenance - CCIS C-167 C-167 Centralized Maintenance - CCIS (Series 7400 software feature) General Description This FCCS service allows all nodes (NEAX2400 IMX systems) in the multiple FCCS groups (networks where multiple NEAX2400 IMXs are connected via FCCS link) and NEAX2000 IVS systems, connected via CCIS link, to be maintained from a single MAT. The MAT used for this feature is called Centralized MAT. Note:...
Page 882
NEAX2400 IMX Feature Programming Manual Page 838ND-70184 (E), Issue 3 C-167 Centralized Maintenance - CCIS FCCS Programming This data setting describes only the additional or replacement commands used to activate FCCS services. When used as an FCCS feature, these commands replace the non-network commands (for example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending on the node. Assign the following data at the NCN in each FCCS group (FUG) STEP 1:AFUGN - Assign...
Page 883
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 839 Centralized Maintenance - CCIS C-167 FCCS Programming (cont’d) To connect FUG and a NEAX2000 IVS (refer to the manuals for the NEAX2000 IVS for data programming on the NEAX2000 IVS side): To connect a NEAX2400 IMX and a NEAX2400 IMX (NEAX2400 IMX stands for the FCCS node working alone in an FCCS network): Center FUGFPC 1 PC 1 FUG 1 FPC 3 PC 3 NCN FPC 2 PC 2CCIS - - - - - - - - -- - - NEAX2000 IVS Center FUGFPC 1 NCN PC 4 FPC 4 PC...
Page 884
NEAX2400 IMX Feature Programming Manual Page 840ND-70184 (E), Issue 3 D-41 Data Communication - CCIS D-41 Data Communication - CCIS General Description This service allows Inter-Office data communication service where the Digital Interface (DTI) is used as the CCIS Line over a T1 channel (Digital Link Channel). With this service, the data communication line between synchronous and asynchronous terminals can be directly connected to the DTI without using the MODEM Pooling or a DST card. Operating...
Page 885
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 841 Data Communication - CCIS D-41 Operating Procedure (cont’d) When cancelling the data connection: 1. Press the DATA key on Dterm (a); the LCD of Dterm (a) restores the display of Time and Date. Note: If the opposite DTE is released, the buzzer on the Data Module/Data Adapter sounds three times. Enter Release command RLS RETURN from the keyboard of the DTE. RLS and RELEASED are displayed on the monitor screen. The data connection has...
Page 886
NEAX2400 IMX Feature Programming Manual Page 842ND-70184 (E), Issue 3 D-65 Data Interface - Automatic Answer - CCIS D-65 Data Interface - Automatic Answer - CCIS General Description This feature allows a data terminal to automatically answer an incoming CCIS call without manual operation, therefore, providing the capability of receiving electronic mail. Operating Procedure To activate AUTOMATIC ANSWER for terminating data calls, Automatic Answer Mode can be set by any of the following methods: 1. Set...
Page 887
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 843 Data Interface - Automatic Answer - CCIS D-65 Programming (cont’d) KYI: Service Index 0: Key Not Used 1: Feature Key 2: Multi-line Key KD: Not assigned for Feature Key FKY: Feature Key Number FKY = 30, AUTOMATIC ANSWER
Page 888
NEAX2400 IMX Feature Programming Manual Page 844ND-70184 (E), Issue 3 D-66 Data Line Security - CCIS D-66 Data Line Security - CCIS General Description This feature allows line circuits used for data transmission to be protected from interruptions, such as, ATTENDANT CAMP-ON WITH TONE INDICATION - CCIS [A-45], BUSY VERIFICATION - CCIS [B-9], EXECUTIVE RIGHT-OF-WAY - CCIS [E-8], and ATTENDANT OVERRIDE [A-7]. Operating Procedure No manual operation is required. Service Conditions 1. If an Attendant or...
Page 889
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 845 Data Line Privacy - CCIS D-67 D-67 Data Line Privacy - CCIS General Description This feature automatically prevents interruptions from features such as ATTENDANT CAMP-ON WITH TONE INDICATION - CCIS [A-45], BUSY VERIFICATION - CCIS [B-9], and EXECUTIVE RIGHT-OF-WAY - CCIS [E-8] during data transmission through the CCIS network. Operating Procedure Data Connection (Dterm-Data Adapter/Data Module): No manual operation is required. When...
Page 890
NEAX2400 IMX Feature Programming Manual Page 846ND-70184 (E), Issue 3 D-68 Data Privacy on Demand - CCIS D-68 Data Privacy on Demand - CCIS General Description This feature allows a user to prevent interruptions by features such as ATTENDANT CAMP-ON - CCIS [A-45], BUSY VERIFICATION - CCIS [B-9], and EXECUTIVE RIGHT-OF-WAY - CCIS [E-8] during data transmission through the CCIS network by dialing a DATA PRIVACY feature code. When the incoming call cannot be restricted since data communication is...