LDN Night Connection - CCIS L-29
Service Conditions (cont’d)
7. If the system changes to Night Mode during a call termination to the Attendant Console, an LDN incoming
call will be connected to the transfer destination associated with the LDN dialed. If this connection is not
possible because of the status of the transfer destination, the call is handled by the next-ranked Night
Connection service (Night Connection Outside, TAS etc.),...

Page 932

NEAX2400 IMX Feature Programming Manual
Page 888ND-70184 (E), Issue 3
M-34 Message Reminder - CCIS
M-34 Message Reminder - CCIS
General Description
This service feature allows Inter-Office Message Reminder when the calling station and the called station belong to
different PBXs in the CCIS network.
Operating Procedure
From Dterm to Dterm:
1. Dterm A and B are engaging in a call.
2. D
term C goes off-hook and dials the number for Dterm B; receives busy tone.
3. D
term C presses the MSG key and receives...

Page 933

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 889
Message Reminder - CCIS M-34
Operating Procedure (cont’d)
5. Dterm B hangs up. 
6. While the message lamp illuminates, D
term B goes off-hook or presses the SPEAKER key and receives
dial tone. 
7. D
term B presses the MSG key and receives ringback tone. Redial is automatically made to Dterm C, and
Dterm C rings.
From a single-line Station to a Dterm:
1. Dterms A and B are engaging in a call.
 
N
E
C
NE
C
NE
C
Dterm (a)
[Node A][Node...

Page 934

NEAX2400 IMX Feature Programming Manual
Page 890ND-70184 (E), Issue 3
M-34 Message Reminder - CCIS
Operating Procedure (cont’d)
2. Station C goes off-hook and dials the number for Dterm B; receives busy tone.
3. Station C switch hook flashes; receives special dial tone.
4. Station C dials the MESSAGE REMINDER access code; receives service set tone. The MESSAGE lamp
on D
term B illuminates, indicating that the message has been set.
5. D
term B hangs up.
6. While the message lamp illuminates, D
term B goes...

Page 935

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 891
Message Reminder - CCIS M-34
Operating Procedure (cont’d)
7. Dterm B presses the MSG key and receives ringback tone. Redial is automatically made to Station C and
Station C rings.
Service Conditions
1. A message can be sent out only when the called station is either idle or busy.
2. A message can be sent out during ringing, recall from Call Transfer-All Calls, or recall from Consultation
Hold-All Calls.
3. A maximum of four messages...

Page 936

NEAX2400 IMX Feature Programming Manual
Page 892ND-70184 (E), Issue 3
M-34 Message Reminder - CCIS
Programming (cont’d)
STEP 2:ANPD - Assign minimum necessary number of digits for the first number of the Access Code of
Message Reminder service. 
STEP 3:ASPA - Assign the Access Code of the Message Reminder service.
CI = H (Hooking)SRV = SSCA (Service Code Appendix) 
CI = B (Busy)SIDA = 42: 
STEP 4:ASFC - With respect to SFC of the stations which sets Message Reminder service, cancel the
restriction of SFI...

Page 937

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 893
Message Reminder - Dterm - CCIS M-34D
M-34D Message Reminder - Dterm - CCIS
General Description
This feature allows a Dterm to leave a MESSAGE REMINDER at a Dterm in a different node in the CCIS network.
Operating Procedure
To activate MESSAGE REMINDER - CCIS from a Dterm to an idle or busy Dterm: 
1. Lift the handset; receive dial tone. 
2. Dial the desired D
term at the distant office; receive ringback tone or busy tone. 
3. Press...

Page 938

NEAX2400 IMX Feature Programming Manual
Page 894ND-70184 (E), Issue 3
M-34D Message Reminder - Dterm - CCIS
Service Conditions
1. This feature is only available between two Dterm sets that both have the MESSAGE feature key. If a
message is directed to a single line or a Dterm that does not have the MESSAGE REMINDER feature, the
calling stations LCD displays:
2. Messages cannot be sent while engaged in calling or recall from CALL TRANSFER - ALL CALLS [C-
11] [C-50] or from CONSULTATION HOLD - ALL CALLS...

Page 939

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 895
Message Reminder - Dterm - CCIS M-34D
Programming (cont’d)
STEP 3:ASPA - Assign an access code to MESSAGE REMINDER; assign SRV = SSCA (Service Code
Appendix), SIDA = 42. Assign a Connection Index of Normal (N) and Busy (B).
STEP 4:ASFC - Assign to the single-line stations that will have MESSAGE REMINDER a Service Feature
Class that allows SFI53.
 (Note)
STEP 5:AKYD - Assign the station according to the following parameters:
TN: 1
STN:...

Page 940

NEAX2400 IMX Feature Programming Manual
Page 896ND-70184 (E), Issue 3
M-35 Message Waiting Lamp Setting - Attendant - CCIS
M-35  Message Waiting Lamp Setting - Attendant - 
CCIS
General Description
This service feature allows the MESSAGE WAITING (MW) lamp on the Dterm or telephone set, equipped with MW
lamp accommodated in the Satellite Offices, to be controlled from the Attendant Console in the CCIS network.
Operating Procedure
To set MW Indication:
1. The Attendant in Node A presses an idle loop key....