Page 941
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 897 Message Waiting Lamp Setting - Attendant - CCIS M-35 Programming STEP 1:ANPD - Assign minimum necessary number of digits for the first number of the access code and connection index for MW service. STEP 2:ASPA - Assign the access code and connection index for MW service. To Set: CI = N (Normal), SRV = SSCA (Service Code Appendix), SIDA = 54 To Cancel:CI = N (Normal), SRV = SSCA (Service Code Appendix), SIDA = 55 STEP 3:ASFC - Allow MW...
Page 942
NEAX2400 IMX Feature Programming Manual Page 898ND-70184 (E), Issue 3 M-36 Message Waiting Lamp Setting - Station - CCIS M-36 Message Waiting Lamp Setting - Station - CCIS General Description This feature allows any Dterm or single line telephone to set/cancel a MESSAGE WAITING indication or lamp at any other station equipped with this feature in the CCIS network. Operating Procedure To set MESSAGE WAITING LAMP SETTING-STATION - CCIS from a single line telephone: 1. Lift the handset; receive dial...
Page 943
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 899 Message Waiting Lamp Setting - Station - CCIS M-36 Service Conditions (cont’d) 6. If a user attempts to set MESSAGE WAITING to a station where MESSAGE WAITING has already been set, busy tone will be sent to the station, and the Dterm display phones will display: 7. When a station is restricted from MESSAGE WAITING LAMP SETTING-STATION - CCIS or is an unused telephone number, and another user attempts to set/cancel MESSAGE WAITING...
Page 944
NEAX2400 IMX Feature Programming Manual Page 900ND-70184 (E), Issue 3 M-37 Miscellaneous Trunk Access - CCIS M-37 Miscellaneous Trunk Access - CCIS General Description This feature provides access through the CCIS network to all types of external and customer provided equipment/ facilities, such as TIE LINE ACCESS [T-3], as well as DICTATION ACCESS [D-3], PAGING ACCESS - CCIS, and CODE CALLING ACCESS [C-21]. Operating Procedure MISCELLANEOUS TRUNK ACCESS - CCIS is programmed in System Data via the...
Page 945
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 901 Miscellaneous Trunk Restriction - CCIS M-38 M-38 Miscellaneous Trunk Restriction - CCIS General Description This feature allows certain stations and dial-repeating TIE Line trunks to be denied access through CCIS to certain trunk routes, such as TIE LINE ACCESS [T-3], as well as the Exchange Network, DICTATION ACCESS [D-3], or PAGING ACCESS - CCIS [P-28]. Operating Procedure No manual operation is required. Restricted stations will...
Page 946
NEAX2400 IMX Feature Programming Manual Page 902ND-70184 (E), Issue 3 M-39 Modem Pooling - CCIS M-39 Modem Pooling - CCIS General Description This feature allows any terminal to have access to a data terminal in a different office through a concentration of modem groups, set at different data speeds, using the Common Channel Inter-Office Signaling System. A maximum of 8 Modem Groups are provided. One modem in the group is selected by the data station, at the time of Modem Pool selection. Least Cost...
Page 947
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 903 Modem Pooling - CCIS M-39 Service Conditions (cont’d) 8. Distinctive Ringing - Most modems recognize only a 2-second on, 1-second off ring. This consideration must be taken into account when defining incoming trunk ringing. 9. The Reverse or Secondary Channel feature of modems is not implemented on the Modem Pool card. 10. Speed Select using pin 23 on the EIA RS232 connector is not implemented. 11. Intelligent or Auto Dial Modems must...
Page 948
NEAX2400 IMX Feature Programming Manual Page 904ND-70184 (E), Issue 3 M-39 Modem Pooling - CCIS Programming (cont’d) SPEED: 0 ASYNC: 0 FCY: 0 STEP 2:AT R K - To program the PA-M20 MODEM POOLING Trunk Circuit Card, assign the LEN Number, MODEM POOLING Route Number (919 - 926), Trunk Number, and Tenant Number. Levels 0, 2, 4 & 6, of the corresponding group number where the PA-M20 Circuit Card is mounted are used for the MODEM POOLING trunks. STEP 3:MBTK - Assign the Make Idle status to the MODEM POOLING...
Page 949
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 905 Multiple Call Forwarding - All Calls - CCIS M-40 M-40 Multiple Call Forwarding - All Calls - CCIS General Description This service feature permits all calls destined for a particular station in a CCIS network to be routed to another station or to the attendant multiple times, regardless of the busy or idle status of the called station. 1. With CALL FORWARDING-ALL CALLS [C-5] (CF-A): 2. With MULTIPLE CALL FORWARDING-ALL CALLS [M-44]...
Page 950
NEAX2400 IMX Feature Programming Manual Page 906ND-70184 (E), Issue 3 M-40 Multiple Call Forwarding - All Calls - CCIS Service Conditions (cont’d) 3. When CALL FORWARDING is performed in a CCIS network, the following services are not available at a forwarded-to station: CALL FORWARDING-ALL CALLS-OUTSIDE [C-28] CALL FORWARDING-BUSY LINE-OUTSIDE [C-60] CALL FORWARDING-DON’T ANSWER-OUTSIDE [C-74] 4. When a call is forwarded to the calling party by CALL FORWARDING-ALL CALLS - CCIS [M-40], the calling party...