Page 551
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 507 MF Signaling - DID M-84 Programming (cont’d) STEP 9:AOP R - Assign the route number, including the alternative route to the outgoing route selection pattern (OPR). Assigns the number of skipped digits and pattern number location (PNL) to each route. STEP 10:ARSC - Release the dummy route and station connection restriction. Release the connection restriction on the route of the MF line and station. FCCS Programming This data setting...
Page 552
NEAX2400 IMX Feature Programming Manual Page 508ND-70184 (E), Issue 3 M-85D Message Waiting Indication - Dterm M-85D Message Waiting Indication - Dterm General Description This feature allows Message Waiting (MW) information to be displayed on the middle line (24 digits) of the LCD. Operating Procedure No manual operation is required. Service Conditions 1. The LCD displays the following information, when MESSAGE WAITING INDICATION - Dterm is activated: 2. When this service is assigned to a D term with a...
Page 553
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 509 MF ANI to SMDR M-101 M-101 MF ANI to SMDR General Description This feature allows an office receiving ANI information by means of MF signal to output the information to the expanded SMDR area. Operating Procedure No manual operation is required. Service Conditions 1. Output conditions are same as current conditions of MF ANI. (i.e., charging information for incoming calls is output only). 2. About the expanded output format, refer to...
Page 554
NEAX2400 IMX Feature Programming Manual Page 510ND-70184 (E), Issue 3 M-101 MF ANI to SMDR Programming (cont’d) System Data 1, Index 288, Bit 5. Expanded SMDR Output for SMDR A Apparatus. 0/1 = Out/In Service. System Data 1, Index 290, Bit 5. Expanded SMDR Output for SMDR B Apparatus. 0/1 = Out/In Service. System Data 1, Index 292, Bit 5. Expanded SMDR Output for SMDR C Apparatus. 0/1 = Out/In Service. System Data 1, Index 294, Bit 5. Expanded SMDR Output for SMDR D Apparatus. 0/1 = Out/In Service....
Page 555
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 511 MF ANI to SMDR M-101 FCCS Programming (cont’d) When Calling Number is output to SMDR, the following expanded format is used. System Data 1, Index 288, Bit 5. Expanded SMDR Output for SMDR A Apparatus. 0/1 = Out/In Service. System Data 1, Index 290, Bit 5. Expanded SMDR Output for SMDR B Apparatus. 0/1 = Out/In Service. System Data 1, Index 292, Bit 5. Expanded SMDR Output for SMDR C Apparatus. 0/1 = Out/In Service. System Data 1,...
Page 556
NEAX2400 IMX Feature Programming Manual Page 512ND-70184 (E), Issue 3 N-1 Night Connection - Fixed N-1 Night Connection - Fixed General Description This feature routes calls normally directed to the ATTENDANT CONSOLE [A-3] to a preselected common station within the system when the Night Mode has been entered. Operating Procedure To answer NIGHT CONNECTION calls: 1. The incoming calls to the ATTENDANT CONSOLE [A-3] in the night mode are automatically transferred to a preselected NIGHT CONNECTION - FIXED...
Page 557
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 513 Night Connection - Fixed N-1 Interactions (cont’d) 5. When the NIGHT CONNECTION - FLEXIBLE [N-2] feature is provided, assignments can be made by the ATTENDANT CONSOLE [A-3] or NIGHT CONNECTION - FIXED station by use of the CALL FORWARDING - ALL CALLS [C-5] feature. 6. CALL FORWARDING - BUSY LINE/DONT ANSWER [C-2, 3]: A Night user can activate the CALL FORWARDING - BUSY LINE/DONT ANSWER [C-2, 3] feature if available to the user. A call...
Page 558
NEAX2400 IMX Feature Programming Manual Page 514ND-70184 (E), Issue 3 N-1 Night Connection - Fixed Programming STEP 1:ASYD - System Data 1, Index 147. DIT supervisory timer for a busy station. How often will the CPU look at the Idle/Busy status of the station for rerouting the DIT call to the destination? Always leave this index as 00H. For NIGHT CONNECTION-FIXED Only. STEP 2:ACSI - Assign Route Number, Trunk Number, Connection Service Index of “4” for NIGHT CONNECTION-FIXED, and the Tenant Number and...
Page 559
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 515 Night Connection - Flexible N-2 N-2 Night Connection - Flexible General Description This feature provides arrangements to route calls, usually directed to the ATTENDANT CONSOLE [A-3], instead to a preselected station on a flexible, assignable basis within the system, when the Night Mode has been entered. Operating Procedure 1. Answering the operation is the same as that for NIGHT CONNECTION - FIXED [N-1]. 2. Each evening, before...
Page 560
NEAX2400 IMX Feature Programming Manual Page 516ND-70184 (E), Issue 3 N-3 Non-delay Operation N-3 Non-delay Operation General Description This feature allows the ATTENDANT CONSOLE [A-3] to place any calling party on hold, dialing the call, and connecting the calling and called parties. Operating Procedure 1. The Attendant answers an operator call by pressing the ANSWER or ATND key. 2. Press the START key. 3. Dial the exchange network access code. 4. Dial the desired telephone number. 5. Press the...