Page 601

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 557
Peg Count P-7
Service Conditions (cont’d)
5. Traffic measurement duration time is designated for more than one hour. If the traffic measurement
duration time is not designated, the measurement is performed indefinitely until a stop command is entered
on the MAT [M-18].
Interactions 
If the system is reset, traffic measurement requests are no longer in service.
Programming
To Order PEG COUNTS:
ASYD - System Data 1, Index 47, bit 7 =...

Page 602

NEAX2400 IMX Feature Programming Manual
Page 558ND-70184 (E), Issue 3
P-7 Peg Count
Programming (cont’d)
STEP 2:DTF2 - Display of Traffic Data 2
TYPE: Type of Traffic Measurement
6: Service Peg Count
STEP 3:DTF3 - Display of Traffic Data 3
TYPE: Type of Traffic Measurement 
8: UCD Route Peg Count 
9: UCD Group Peg Count 
10: UCD Station Peg Count
STEP 4:DTF4 - Display of Traffic Data 4
11: CCIS Traffic Count 
FCCS Programming 
No unique programming is required for the FCCS network. 

Page 603

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 559
Priority Call P-9
P-9 Priority Call
General Description
This feature allows the ATTENDANT CONSOLE [A-3] to answer various types of calls in the order of their
priority. A special type of call can be handled prior to a regular call, at the Attendants discretion.
Operating Procedure
1. Lift the handset and receive dial tone.
2. Dial the PRIORITY CALL number, then wait for the Attendant to answer.
Note:
PRIORITY CALL will terminate on a...

Page 604

NEAX2400 IMX Feature Programming Manual
Page 560ND-70184 (E), Issue 3
P-9 Priority Call
Interactions (cont’d)
3. If the destination of a Priority Call is the Attendant Console, the Priority Call does not transfer to the
ATTENDANT NIGHT TRANSFER [A-19] station when the system goes into Night mode.
4. A PRIORITY CALL will not be forwarded to outside.
Programming
STEP 1:ASYD - System Data 1, Index 168, Bit 6. Where will Priority Call terminate? 0/1: Attendant Console/
Station. If Attendant Console (0), go...

Page 605

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 561
Priority Call P-9
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
 (Note)
STEP 1:ASPAL - This data must be set to the node calling the attendant.
Assign the FPC of the...

Page 606

NEAX2400 IMX Feature Programming Manual
Page 562ND-70184 (E), Issue 3
P-10 Paging Transfer
P-10 Paging Transfer
General Description
This feature allows a user to transfer a paged call to a party that has been placed on hold.
Operating Procedure
While a user is engaged in a call:
1. Switch hook flash or press TRANSFER key (on Dterm phone); receive special dial tone.
2. Dial the Paging Access Code; receive continuous ringback tone for approximately one second.
3. Page the desired party.
There are three...

Page 607

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 563
Paging Transfer P-10
Service Conditions (cont’d)
8. When using this feature via the FCCS network, when PAGING ACCESS [P-1]/PAGING TRANSFER [P-
10]/RADIO PAGING [R-16] service is set to a station in the remote node or the PAGING ACCESS [P-
1]/PAGING TRANSFER [P-10]/RADIO PAGING [R-16] call is answered from the remote node via
FCCS link:
a.) the logical route number should be applied to each physical route that is provided the service....

Page 608

NEAX2400 IMX Feature Programming Manual
Page 564ND-70184 (E), Issue 3
P-10 Paging Transfer
Programming (cont’d)
System Data 2, Index 1, Bits 0 & 1. Consultation Hold allowed or denied. 00: Denied; 01: Originating
and Terminating Calls allowed; Tandem Call Denied; 11: All calls allowed.
STEP 2:ARTD - Assign the paging route as shown below:
RT:  1
1-OSGS :2 2-ONSG :3 5-TF :1 6-TCL :8 7-L/T :1
8-RLP :2 15-LSG :1
STEP 3:AT R K - Assign the LENs, Paging Trunk Route Number, Trunk Number, and Tenant Number....

Page 609

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 565
Periodic Time Indication Tone P-11
P-11  Periodic Time Indication Tone
General Description
This feature provides a tone every 180 seconds, if required, to the user who has made an outgoing call.
Operating Procedure
No manual operation is required.
Service Conditions
1. This feature is programmed on a per-trunk route basis using the MAINTENANCE ADMINISTRATION
TERMINAL (MAT) [M-18].
2. The PERIODIC TIME INDICATION TONE is 80 ms in...

Page 610

NEAX2400 IMX Feature Programming Manual
Page 566ND-70184 (E), Issue 3
P-11 Periodic Time Indication Tone
Programming
STEP 1:ASYD - System Data 1, Index 137. This timer sets the interval when the first tone will be sent to the
station. Assign 00H for 3 minutes.
System Data 1, Index 138. This timer sets the period between the first and second tones and all other
subsequent tones. Assign 00H for 3 minutes. 
STEP 2:ARTD - Assign CDN 29:TELP. Flag the routes with which the tone will operate. 
STEP 3:ASFC -...