Page 641
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 597 Radio Paging R-16 Programming (cont’d) If the paged party doesn’t respond by the same period of time after the second page, the page is cancelled. System Data 1, Index 244, bit 0. Answer by Radio Paging answer code. 0/1: Out/In Service. Note that this bit is valid when System Data 1, Index 73, bit 4 is 1 (Station Number/Individual ATT Number is automatically sent). STEP 2:ARTD - Assign the Radio Paging route as shown below: RT: 1...
Page 642
NEAX2400 IMX Feature Programming Manual Page 598ND-70184 (E), Issue 3 R-27 Route Restriction - Announcement R-27 Route Restriction - Announcement General Description This feature permits a station-originated call, dialed to a restricted outgoing number, to be automatically routed to a recorded announcement informing the caller that the dialed number is restricted. (TOLL RESTRICTION [T-7]) Operating Procedure No manual operation is required after this feature has been programmed in System Data. Service...
Page 643
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 599 RS-464A PAD R-37 R-37 RS-464A PAD General Description This service is for changing the current PAD control system for the lines and external trunks to a PAD control system which conforms to the RS-464A specification. The following table outlines the comparison between the current PAD control and the RS-464A PAD control. Note: ONS: Line interface to On-Premises Line (General Telephone) OPS: Line interface to Off-Premises Line (Log...
Page 644
NEAX2400 IMX Feature Programming Manual Page 600ND-70184 (E), Issue 3 R-37 RS-464A PAD General Description (cont’d) PAD PATTERN 2 PAD PATTERN 2 PAD PATTERN 2 24 DTR with SFI 50 = 0 24 DTR with SFI 50 = 1 24DTR with APAD Setting ARTD PA D SettingTr a n s m i t PA DReceive PA DARTD PA D 2Transmit PA DReceive PA DAPAD SettingTr a n s m i t PA DReceive PA D 0-9db-3db 0ARTD, PA DARTD, PA D1 -3db +3db 1 -3db +3db 1 -3db +3db 2 -3db -3db 2 -3db -3db 2 -3db -3db 3 -6db 0db 3 -6db 0db 3 -6db 0db 4...
Page 645
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 601 RS-464A PAD R-37 General Description (cont’d) In 4 Wire E+M Mode, the 8TLTR can set PAD values using switch settings and ARTD and APAD values. In the following table, P0 and P1 are assigned by setting ARTD to a value of 0, CDN 30:PAD and setting values by using Switch 1 (P0) and Switch 2 (P1). P2 and P3 are assigned by setting ARTD/APAD to a value of 5, and PAD values are set by using Switch 3 positions 1, 2, 3 and 4 (P2) and...
Page 646
NEAX2400 IMX Feature Programming Manual Page 602ND-70184 (E), Issue 3 R-37 RS-464A PAD Service Conditions (cont’d) 3. An Attendant Console is regarded as an ONS. The Attendant Console will follow the PAD values assigned in ARTD. 4. If PAD data is assigned by APAD command, this data overrides other PAD data assigned by ARTD, except when switch settings on the 24DTR are set to ARTD fixed. 5. PAD settings for the 8TLTR can be set using ARTD/APAD or a combination of switch settings and ARTD/APAD. 6. This...
Page 647
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 603 Ringer Mute R-49 R-49 Ringer Mute General Description This feature allows a user to stop ringing by pressing the associated feature key on the Dterm. Operating Procedure 1. The Dterm user presses the RINGER MUTE key; the ringing is muted and the LED of the key lights. RING OFF is displayed for three seconds. 2. The D term user presses the RINGER MUTE key again; the ringing is recovered and the LED of the key is turned off. RING ON is...
Page 648
NEAX2400 IMX Feature Programming Manual Page 604ND-70184 (E), Issue 3 R-51 Route Name Display R-51 Route Name Display General Description This feature allows a user to assign a desired trunk type for a route by the system data. The assigned trunk type (maximum of 4 or 8 digits) is displayed on the upper line of Dterm LCD. 4-digit display TK No. 8-digit display Note: Trunk type, which can be changed by system data. Operating Procedure No manual operation is required. Service Conditions 1. Trunk types...
Page 649
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 605 Route Name Display R-51 Service Conditions (cont’d) 8-digit display 8. This feature is available when the D term user presses the call terminating sub line. This feature is also available when the user presses the held sub line after holding a call using the HOLD key. 9. For data assignment to each of NDM (Network Data Memory) and LDM (Local Data Memory), different commands can be used. However, the data in NDM has a priority. The...
Page 650
NEAX2400 IMX Feature Programming Manual Page 606ND-70184 (E), Issue 3 S-1 Single-Digit Station Calling S-1 Single-Digit Station Calling General Description This feature allows the assignment of single digits for station numbers. Operating Procedure 1. Lift the handset; receive dial tone. 2. Dial the Single-digit (preprogrammed) telephone number. 3. The desired service station will be rung. Service Conditions 1. The single-digit number must be different from the first digit of trunk access codes, service...