Page 501
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 457 Message Reminder M-19 Service Conditions (cont’d) 12. A maximum of 32 digits can be saved at the called party. 13. To memorize the telephone number of the calling station, assign SYS1, index 641, b0=1 by the ASYDN command. Programming STEP 1:ASYD - System Data 1, Index 17, Bit 0. Single-line stations able to use VOICE CALL [V-2D] and MESSAGE REMINDER features to a D term while hearing ringback tone? 0/1: Restricted/Allowed. System...
Page 502
NEAX2400 IMX Feature Programming Manual Page 458ND-70184 (E), Issue 3 M-19D Message Reminder - Dterm M-19D Message Reminder - Dterm General Description This feature allows a Dterm to leave a MESSAGE REMINDER at another Dterm. Operating Procedure To send a message from a Dterm: 1. Dial the desired Dterm station, receive ringback tone or busy tone. 2. Press the MSG key; the LCD displays: Service set tone is heard. 3. At the called D term, the MSG LED will light to indicate a message has been set. To...
Page 503
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 459 Message Reminder - DtermM-19D Service Conditions (cont’d) 5. Messages can be displayed only when the station is on-hook. A message may be cleared by displaying the message and pressing the “*” or “#” key on the called Dterms key pad. 6. A message is cleared when it is obtained via the MSG key. 7. Messages cannot be cleared by the message sender. 8. A second message sent by the same calling D term is registered as a second unique...
Page 504
NEAX2400 IMX Feature Programming Manual Page 460ND-70184 (E), Issue 3 M-19D Message Reminder - Dterm Programming (cont’d) STEP 3:ANPD - Reserve a number level for feature access. Assign for Normal (N), Hooking (H), and Busy (B). Assign NND in accordance with predetermined Numbering Plan. STEP 4:ASPA - Assign an access code to Message Reminder; assign SRV = SSCA (Service Code Appendix), SIDA = 42; assign Hooking (H), and Busy (B). For Dterms: STEP 5:ASYD - System Data 1, Index 80, Bit 1. Message...
Page 505
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 461 Multiple Line Operation - DtermM-20D M-20D Multiple Line Operation - Dterm General Description This feature allows for the appearance of multiple lines on the programmable line/feature keys of the Dterm set. Operating Procedure No manual operation is required. Service Conditions 1. Three kinds of lines can appear on Dterms: MY Line (ML): This line is associated with the extension number assigned to the port on the interface circuit....
Page 506
NEAX2400 IMX Feature Programming Manual Page 462ND-70184 (E), Issue 3 M-20D Multiple Line Operation - Dterm Programming (cont’d) 0: Key Not Used 1: Feature Key 2: Multi-line Key KD: Not assigned for Feature Key TN STN: Tenant Number and Station Number of Multi-line RG: Ringing Assignment per Multi-line Appearance 0: No Ringing 1: Ringing in Day Mode Only 2: Ringing in Night Mode Only 3: Ringing in Day and Night Mode
Page 507
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 463 Message Waiting Lamp Setting - Attendant M-23 M-23 Message Waiting Lamp Setting - Attendant General Description This feature permits an ATTENDANT CONSOLE [A-3] to set or cancel a Message Waiting indication on a station provided with this feature. Operating Procedure To set a Message Waiting indication: 1. Press an idle loop key. 2. Dial the Message Waiting set code (up to 3 digits); receive special dial tone. 3. Dial the telephone...
Page 508
NEAX2400 IMX Feature Programming Manual Page 464ND-70184 (E), Issue 3 M-23 Message Waiting Lamp Setting - Attendant Service Conditions (cont’d) 7. When Call Indicator Lamp (Note) is controlled by MESSAGE WAITING LAMP SETTING - STATION [M-30], the tone and display indication of the Attendant Console and Call Indicator Lamp of the station are as follows, depending on the status of the station. Interactions 1. For MESSAGE WAITING LAMP SETTING-ATTENDANT, an 8DLC/16ELC card is required. 2. An external power...
Page 509
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 465 Message Waiting Lamp Setting - Attendant M-23 FCCS Programming This data setting describes only the additional or replacement commands used to activate FCCS services. When used as an FCCS feature, these commands replace the non-network commands (for example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending on the node. STEP 1:ANPDL - Reserve a number level for feature access and cancel. Assign...
Page 510
NEAX2400 IMX Feature Programming Manual Page 466ND-70184 (E), Issue 3 M-24 Multiple Call Forwarding - Busy Line M-24 Multiple Call Forwarding - Busy Line General Description This feature permits a call to a busy station to be forwarded, a maximum of five times, to preprogrammed idle stations. Existing CALL FORWARDING - BUSY LINE [C-2] service MULTIPLE CALL FORWARDING - BUSY LINE [M-24] service Operating Procedure To set CALL FORWARDING - BUSY LINE [C-2] from an individual station: 1. Lift the handset;...