Page 501

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 457
Message Reminder M-19
Service Conditions (cont’d)
12. A maximum of 32 digits can be saved at the called party.
13. To memorize the telephone number of the calling station, assign SYS1, index 641, b0=1 by the ASYDN
command.
Programming
STEP 1:ASYD - System Data 1, Index 17, Bit 0.
Single-line stations able to use VOICE CALL [V-2D] and MESSAGE REMINDER features to a D
term
while hearing ringback tone? 0/1: Restricted/Allowed.
System...

Page 502

NEAX2400 IMX Feature Programming Manual
Page 458ND-70184 (E), Issue 3
M-19D Message Reminder - Dterm
M-19D Message Reminder - Dterm
General Description
This feature allows a Dterm to leave a MESSAGE REMINDER at another Dterm.
Operating Procedure
To send a message from a Dterm: 
1. Dial the desired Dterm station, receive ringback tone or busy tone.
2. Press the MSG key; the LCD displays:
Service set tone is heard.
3. At the called D
term, the MSG LED will light to indicate a message has been set.
To...

Page 503

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 459
Message Reminder - DtermM-19D
Service Conditions (cont’d)
5. Messages can be displayed only when the station is on-hook. A message may be cleared by displaying the
message and pressing the “*” or “#” key on the called Dterms key pad.
6. A message is cleared when it is obtained via the MSG key.
7. Messages cannot be cleared by the message sender.
8. A second message sent by the same calling D
term is registered as a second unique...

Page 504

NEAX2400 IMX Feature Programming Manual
Page 460ND-70184 (E), Issue 3
M-19D Message Reminder - Dterm
Programming (cont’d)
STEP 3:ANPD - Reserve a number level for feature access. Assign for Normal (N), Hooking (H), and Busy
(B). Assign NND in accordance with predetermined Numbering Plan. 
STEP 4:ASPA - Assign an access code to Message Reminder; assign SRV = SSCA (Service Code Appendix),
SIDA = 42; assign Hooking (H), and Busy (B). 
For Dterms:
STEP 5:ASYD - System Data 1, Index 80, Bit 1. Message...

Page 505

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 461
Multiple Line Operation - DtermM-20D
M-20D  Multiple Line Operation - Dterm
General Description
This feature allows for the appearance of multiple lines on the programmable line/feature keys of the Dterm set.
Operating Procedure
No manual operation is required.
Service Conditions
1. Three kinds of lines can appear on Dterms:
MY Line (ML): This line is associated with the extension number assigned to the port on the
interface circuit....

Page 506

NEAX2400 IMX Feature Programming Manual
Page 462ND-70184 (E), Issue 3
M-20D Multiple Line Operation - Dterm
Programming (cont’d)
0: Key Not Used
1: Feature Key 
2: Multi-line Key
KD: Not assigned for Feature Key
TN STN: Tenant Number and Station Number of Multi-line 
RG: Ringing Assignment per Multi-line Appearance
0: No Ringing 
1: Ringing in Day Mode Only
2: Ringing in Night Mode Only 
3: Ringing in Day and Night Mode 

Page 507

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 463
Message Waiting Lamp Setting - Attendant M-23
M-23  Message Waiting Lamp Setting - Attendant
General Description
This feature permits an ATTENDANT CONSOLE [A-3] to set or cancel a Message Waiting indication on a station
provided with this feature.
Operating Procedure
To set a Message Waiting indication:
1. Press an idle loop key. 
2. Dial the Message Waiting set code (up to 3 digits); receive special dial tone.
3. Dial the telephone...

Page 508

NEAX2400 IMX Feature Programming Manual
Page 464ND-70184 (E), Issue 3
M-23 Message Waiting Lamp Setting - Attendant
Service Conditions (cont’d)
7. When Call Indicator Lamp (Note) is controlled by MESSAGE WAITING LAMP SETTING - STATION
[M-30], the tone and display indication of the Attendant Console and Call Indicator Lamp of the station
are as follows, depending on the status of the station.
Interactions
1. For MESSAGE WAITING LAMP SETTING-ATTENDANT, an 8DLC/16ELC card is required.
2. An external power...

Page 509

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 465
Message Waiting Lamp Setting - Attendant M-23
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:ANPDL - Reserve a number level for feature access and cancel. Assign...

Page 510

NEAX2400 IMX Feature Programming Manual
Page 466ND-70184 (E), Issue 3
M-24 Multiple Call Forwarding - Busy Line
M-24  Multiple Call Forwarding - Busy Line
General Description
This feature permits a call to a busy station to be forwarded, a maximum of five times, to preprogrammed idle
stations.
Existing CALL FORWARDING - BUSY LINE [C-2] service
MULTIPLE CALL FORWARDING - BUSY LINE [M-24] service
Operating Procedure
To set CALL FORWARDING - BUSY LINE [C-2] from an individual station:
1. Lift the handset;...