Page 461

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 417
Last Number Called - Single-Line Station L-6
L-6 Last Number Called - Single-Line Station
General Description
When a user originates a station-to-station call or an outgoing trunk call, but the call is not established, this feature
allows the calling station to recall the same destination by dialing only the special code instead of dialing all the
digits of the number.
Operating Procedure
1. Lift the handset; receive dial tone. 
2....

Page 462

NEAX2400 IMX Feature Programming Manual
Page 418ND-70184 (E), Issue 3
L-6 Last Number Called - Single-Line Station
Programming (cont’d)
STEP 3:ASFC - Assign the stations to receive the feature LAST NUMBER CALLED a Service Feature Class
that allows SFI = 44.
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that...

Page 463

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 419
Last Number Called - DtermL-6D
L-6D  Last Number Called - Dterm
General Description
This feature allows the user of a Dterm to store the last five numbers dialed, and to redial the numbers by pressing
the REDIAL key. The Dterm user can choose any destination out of the last 5 calls that have been stored in memory,
thus enabling the user to place a call without redialing the full number.
Operating Procedure
How to check the dialed...

Page 464

NEAX2400 IMX Feature Programming Manual
Page 420ND-70184 (E), Issue 3
L-6D Last Number Called - Dterm
Operating Procedure (cont’d)
6. The called party answers the call.
a.) The Prime Line lights green.
b.) The Speaker Lamp is OFF.
Service Conditions
1. A maximum of 5 destinations can be stored.
2. The maximum digits of the destination is 32 digits.
3. When a feature key has been assigned as Last Number Called, the feature key also works as REDIAL key.
4. This feature is also effective when the calling...

Page 465

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 421
Last Number Called - DtermL-6D
Service Conditions (cont’d)
12. If making an abbreviated call using the REDIAL key, the number dialed is not stored. Therefore, redialing
through LAST NUMBER CALL - stock redial is not available. A newly dialed destination is stored in
accordance with the following flowchart:
Stack #1
Stack #2
Stack #3
Stack #4
Stack #5
Yes
No
The dialed destination and the number stored in the Stack Memory 2 are the...

Page 466

NEAX2400 IMX Feature Programming Manual
Page 422ND-70184 (E), Issue 3
L-6D Last Number Called - Dterm
Service Conditions (cont’d)
Programming
STEP 1:AKYD - Assign a programmable line/feature key as the LAST NUMBER CALLED key, if necessary.
KYI: Service Index 1 (= Feature Key)
FKY: Feature Key Number 8 (= LAST NUMBER CALLED)
STEP 2:ASDT - Assign a D
term with TEC (Telephone Equipment Class) 12.
Stack #1
Stack #2
Stack #3
Stack #4
Stack #5
Yes
No
The dialed destination and the number stored in the Stack...

Page 467

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 423
Line Reconnect - Same Line - DtermL-7D
L-7D Line Reconnect - Same Line - Dterm
General Description
This feature allows a user to disconnect a call and receive dial tone by pressing the RECALL key.
Operating Procedure
While a call is in progress: 
1. Press the RECALL key; disconnect and receive dial tone on the same line. 
2. User is ready to dial again.
Service Conditions
1. Conflicting service features are: CALL TRANSFER - ALL CALLS...

Page 468

NEAX2400 IMX Feature Programming Manual
Page 424ND-70184 (E), Issue 3
L-8D Line Reconnect - Other Line - Dterm
L-8D  Line Reconnect - Other Line - Dterm
General Description
This feature allows a user to select another line key without going on-hook.
Operating Procedure
While off-hook on the original line, press a line key that is either idle or ringing; the user is disconnected from the
original line and connected to the new line.
Service Conditions
1. LINE RECONNECT - OTHER LINE Dterm cannot be used...

Page 469

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 425
Line Pre-selection - DtermL-9D
L-9D Line Pre-selection - Dterm
General Description
This feature provides the user with the ability to select an idle or ringing line before going off-hook.
Operating Procedure
To originate:
1. Press the desired line key; receive dial tone. 
2. Dial the desired destination.
To answer:
1. Press the line key (ringing and flashing LED alerts incoming call). 
2. Lift the handset or press SPEAKER key; answer...

Page 470

NEAX2400 IMX Feature Programming Manual
Page 426ND-70184 (E), Issue 3
L-10 LCR - Time Of Day Routing
L-10  LCR - Time Of Day Routing
General Description
This feature provides automatic routing of outgoing calls over alternative customer facilities, based on the
destination code. The system will select the most economical route available at the time of connection. The pattern
of alternate routing can be changed up to 8 times per day, based on a prearranged time schedule.
Operating Procedure
1. Lift the...