NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 437
LDN Night Connection - Outside L-30
L-30  LDN Night Connection - Outside
General Description
This feature routes LOCAL DIRECTORY NUMBER (LDN) calls to a preselected station outside the system when
the system is in Night mode.
Operating Procedure
To answer LDN NIGHT CONNECTION calls (DID, TIE):
1. An incoming LDN call in Night mode is automatically routed to a preselected LDN NIGHT
CONNECTION station outside the system.
2. The calling...

Page 482

NEAX2400 IMX Feature Programming Manual
Page 438ND-70184 (E), Issue 3
L-30 LDN Night Connection - Outside
Programming (cont’d)
If no, then LDN will only go to Attendant.
If yes, then the following parameters will be enabled:
TYPE: Night Transfer Type 
1: Station number 
2: Outside (up to 8 digits) 
3: ADC (when more than 8 digits are required) 
STN: For Types 1 & 2.
For Type 1, assign station number here.
For Type 2, assign access code and outside number here. 
(A CCIS remote office station number can be...

Page 483

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 439
Meet-Me Paging M-1
M-1 Meet-Me Paging
General Description
This feature allows a user dial access to paging equipment, and connects both parties automatically, after the called
party has answered the page.
Operating Procedure
To page:
1. Calling station dials the Paging access code; receives continuous ringback tone for 1 second. 
2. Calling station pages the desired party. 
3. Calling station remains off-hook or hangs up.
To answer:...

Page 484

NEAX2400 IMX Feature Programming Manual
Page 440ND-70184 (E), Issue 3
M-1 Meet-Me Paging
Interactions (cont’d)
4. BUSY VERIFICATION [B-3] and EXECUTIVE OVERRIDE [E-1]: These features will be denied for a
connection that includes the Paging route.
5. DELAY OPERATION: Station A is connected to party B. Station A momentarily presses the switch hook
and dials the MEET-ME PAGE route access code. When connected to the page, Station A requests Station
C to dial the MEET-ME PAGE answer code. Station A hangs up....

Page 485

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 441
Meet-Me Paging M-1
Programming (cont’d)
STEP 5:ANPD - Reserve levels for trunk access and for MEET-ME PAGE answer and cancel codes. Assign
the trunk access level for a Connection Index (CI) of Normal (N) and Hooking (H) service. Number of
necessary digits is usually one or two. Busy Lamp Field is not activated. If the MEET-ME PAGE
answer and cancel codes reside in a level reserved for features, then assign according to a
predetermined...

Page 486

NEAX2400 IMX Feature Programming Manual
Page 442ND-70184 (E), Issue 3
M-2 Miscellaneous Trunk Access
M-2 Miscellaneous Trunk Access
General Description
This feature provides access to all types of external and customer provided equipment/facilities, such as FX [F-2],
WATS [W-1], CCSA [C-14], TIE LINE [T-3], and Exchange Network, along with DICTATION [D-3], PAGING
[P-1], and CODE CALLING [C-21].
Operating Procedure
MISCELLANEOUS TRUNK ACCESS is accomplished via System Data programming at the MAINTENANCE...

Page 487

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 443
Miscellaneous Trunk Restriction M-3
M-3 Miscellaneous Trunk Restriction
General Description
This feature provides for certain stations and certain dial-repeating TIE trunks to be denied access to particular trunk
groups, such as FX [F-2], WATS [W-1], CCSA [C-14], TIE LINE [T-3], Exchange Network, DICTATION [D-3]
or PAGING [P-1].
Operating Procedure
MISCELLANEOUS TRUNK RESTRICTION is accomplished via system data programming at the...

Page 488

NEAX2400 IMX Feature Programming Manual
Page 444ND-70184 (E), Issue 3
M-3 Miscellaneous Trunk Restriction
Programming
STEP 1:ASYD - System Data 2, Index 1, Bits 4 & 5. Should a restricted station be routed to the Attendant
Console or receive reorder tone?
Reorder Tone: Bit 4 = 0, Bit 5 = 0. 
Attendant Console: Bit 4 = 1, Bit 5 = 0.
STEP 2:ARSC - Follow the procedure for [M-2] MISCELLANEOUS TRUNK ACCESS [M-2]. By assigning
the ARSC command, restrict RSCs from receiving certain routes. RRI 3: RES must be...

Page 489

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 445
Multiple Console Operation M-4
M-4 Multiple Console Operation
General Description
This feature allows one or more ATTENDANT CONSOLEs [A-3] to operate within the same system.
Operating Procedure
No manual operation is required.
Service Conditions
1. The maximum number of consoles per PIM is 4.
2. The maximum number of consoles allowable per system is:
1 IMG: 16
4 IMG/IMX-U: 60
3. Each incoming call is displayed on an ATTENDANT CONSOLE...

Page 490

NEAX2400 IMX Feature Programming Manual
Page 446ND-70184 (E), Issue 3
M-4 Multiple Console Operation
Interactions (cont’d)
4. When more than one Attendant Console is installed, a Primary Attendant Console may be assigned
(AMAT command). This Attendant Console will control the implementation of DAY/NIGHT CLASS OF
SERVICE [D-15].
5. If the Primary Attendant places the system into Night mode, the Night LED on the other consoles do not
light.
Programming
STEP 1:ASYD - System Data 1, Index 9. Assign the...