Page 471

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 427
LCR - Time Of Day Routing L-10
Programming (cont’d)
STEP 2:ASDC - If 6-digit translation is required where both the Area and Office codes must be examined, this
command must be used. The system is automatically set as an Allow table. To create a Deny table,
assign the following:
OFFICE: 0 
EFFECT: 1 
Program the type of route as PFX (Prefix, Foreign Exchange, FX) or as SCC (Special Common
Carrier). 
Choose TDC PTN, Time-of-Day...

Page 472

NEAX2400 IMX Feature Programming Manual
Page 428ND-70184 (E), Issue 3
L-10 LCR - Time Of Day Routing
FCCS Programming (cont’d)
Route Number (RT) - The physical Route Number to be selected.
Skip Digits (SKIP) - The digits to be skipped when translating the dialed digits in AFRS. If ARTD is
assigned as shown, at a minimum, always assign “1” to skip the LCR (S) access code.
Pattern Number Location (PNL) - If digits are to be added after translating the dialed digits in AFRS,
go to the AADC command.
Overflow...

Page 473

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 429
Line Load Control L-11
L-11 Line Load Control
General Description
This feature allows the Attendant to deny a preselected group of stations the ability to originate calls by activating
a key. The sole intention of this feature is to temporarily restrict the least important internal stations from outward
calling during an excessive traffic load or emergency conditions.
Operating Procedure
To activate LINE LOAD CONTROL from the...

Page 474

NEAX2400 IMX Feature Programming Manual
Page 430ND-70184 (E), Issue 3
L-11 Line Load Control
Programming (cont’d)
Note:
Incoming calls terminated to CCIS/ISDN cannot be restricted.
STEP 2:ANPD - Reserve a number level for feature access and cancel. Assign Connection Indexes, CI = N, H,
B; Normal (N), Hooking (H), and Busy (B) (applicable to any feature assigned to this level). Assign
NND in accordance with a predetermined numbering plan.
STEP 3:ASPA - Assign an access code to LINE LOAD CONTROL. Assign...

Page 475

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 431
Line Load Control - Automatic L-20
L-20  Line Load Control - Automatic
General Description
This feature allows the system to automatically deny a preselected group of stations the ability to originate calls. The
sole intention of this feature is to temporarily restrict the least important internal stations from outward calling
during an excessive traffic load or emergency conditions.
Operating Procedure
No manual operation is...

Page 476

NEAX2400 IMX Feature Programming Manual
Page 432ND-70184 (E), Issue 3
L-21 Line Load Control - MAT
L-21 Line Load Control - MAT
General Description
This feature allows the MAT [M-18] to deny a preselected group of stations the ability to originate calls by activating
a command key. The sole intention of this feature is to temporarily restrict the least important internal stations from
outward calling during an excessive traffic load or emergency conditions.
Operating Procedure
The ALLC command is used to...

Page 477

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 433
Listed Directory Number L-24
L-24 Listed Directory Number
General Description
This feature allows Listed Directory Number Display on the ATTENDANT CONSOLE [A-3] when the Attendant
has answered a Listed Directory Number call.
Operating Procedure
1. The Attendant at an ATTENDANT CONSOLE [A-3] answers an incoming call (DID, TIE).
a.) The DEST lamp lights up.
b.) The Listed Directory Number is displayed.
2. The Attendant presses the SRC...

Page 478

NEAX2400 IMX Feature Programming Manual
Page 434ND-70184 (E), Issue 3
L-28 LDN Night Connection
L-28 LDN Night Connection
General Description
This service feature routes LISTED DIRECTORY NUMBER (LDN) calls to a preselected station when the system
is in night mode.
Operating Procedure
To answer LDN NIGHT CONNECTION calls (DID, TIE):
1. An incoming LDN call in night mode is automatically routed to a preselected LDN NIGHT
CONNECTION station within the system. 
2. The calling party receives ringback tone....

Page 479

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 435
LDN Night Connection L-28
Interactions
1. A maximum of 16 LDNs can be assigned per tenant, each with its own separate destination station. The
same destination may also be used for all LDNs.
2. STATION HUNTING-CIRCULAR [S-7] and STATION HUNTING-TERMINAL [S-9] are valid from
the night transfer destination station.
3. MULTIPLE CALL FORWARDING-ALL, BUSY, DON’T ANSWER [M-44, M-24, M-25] and
MULTIPLE CALL FORWARDING-ALL, BUSY, DON’T...

Page 480

NEAX2400 IMX Feature Programming Manual
Page 436ND-70184 (E), Issue 3
L-28 LDN Night Connection
Programming (cont’d)
For Type 1, assign station number here. 
For Type 2, assign access code and outside number here. 
(A CCIS remote office station number can be input here also). 
ADC: For Type 3.
Input ADC number desired as assigned in the ASPD command. 
STEP 2:ACFR - Assign TSFI: 2 (Night Connection-Fixed) to be allowed CCI: 1 (LDN). This allows LDN to
go to night transfer destination. Assign TSFI: 5 (TAS)...